Web Analytics Made Easy - StatCounter

Light Fittings Repair Tenders

Get complete information related to latest Light Fittings Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Light Fittings Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Light Fittings Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45491017 Due date: 07 Jul, 202607 Jul, 2026 60.00 Lacs
Tender For comprehensive repair and maintenance of sewage treatment plants and allied works, dg sets and connected items security light, street light etc at satwari, ridge area, roulki area, mh raipur satwari etc at mil stn jammu under ge satwari

Central Government/Public Sector

CTN :45502471 Due date: 01 Jul, 202601 Jul, 2026 7.00 Lacs
Tender For repair and maint of internal electric supply rewiring switches sockets mcbs dbs light fittings repair and servicing of ceiling fan exhaust fan and geysers

Central Government/Public Sector

CTN :45263918 Due date: 17 Jun, 202617 Jun, 2026 50.00 Lacs
Tender For corrigendum : comprehensive maintenance incl repair/ replacement of security light, solar light and street lights under ge nasik road camp.

Central Government/Public Sector

CTN :45505259 Due date: 30 Jun, 202630 Jun, 2026 45.00 Lacs
Tender For repair maint of dg sets, amf panels, earthings and certain em eqpts and plants including miscellaneous em repairs to installations at af station jodhpur under 32 wing and repair replacement of street light fitting security light fitting, high mast flood lig

Central Government/Public Sector

CTN :45347275 Due date: 22 Jun, 202622 Jun, 2026 45.00 Lacs
Tender For corrigendum : repair, maintenance and replacement of old vintage street/ security light, garden light, post top lantern, bollard light, solar light and allied work at u area under age e/m of ge sukna at mil stn sukna

Central Government/Public Sector

CTN :45322468 Due date: 17 Jun, 202617 Jun, 2026 10.00 Lacs
Tender For corrigendum : repair replacement of street light high mast light security light and connected items at icgs malkapuram jetty at visakhapatnam under ge (i) (cg) vizag

Central Government/Public Sector

CTN :45475154 Due date: 30 Jun, 202630 Jun, 2026 30.00 Lacs
Tender For repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and getting out in an

State Government

CTN :45481768 Due date: 16 Jun, 202616 Jun, 2026 42.29 Lacs
Tender For prov. of garden light, repla. of security light, watch tower light and street light on differ. ward buil., repair of 1 nos old highmast light and differ. ward cable, panel and patch repair of electrical insta. in mandal kara godda.

Central Government/Public Sector

CTN :45465711 Due date: 29 Jun, 202629 Jun, 2026 47.00 Lacs
Tender For repair/replacement of street/security light fittings, ug cables, loop boxes, ftgs and allied works at af stn under ge avadi

Central Government/Public Sector

CTN :45478803 Due date: 29 Jun, 202629 Jun, 2026 29.98 Lacs
Tender For repair/maint of street lights /security lights/high mast lights /facade light,garden light,gate light,post top lantern and allied works zone b at nda khadakwasla
 Loading, Please wait...

Connect us via What's Up