Web Analytics Made Easy - StatCounter

Lightening Arrester Tenders

Get complete information related to latest Lightening Arrester Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lightening Arrester Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lightening Arrester Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45726549 Due date: 20 Jul, 202620 Jul, 2026 NA
Tender For repairs maintenance of electrical and mechanical equipments high mast light search lights and other miscellaneous items at cad pulgaon - disconnecting and taking down existing unserviceable street lights/flood lights any type/watts from pole/wall and dismantling the light fittings. repairing/replacing unserviceable parts re-fixing the same on pole/wall after testing and removal of carbon from line jumpers/tightening of jumper/alignment of fitting defective street light/security light/flood lights fitting/led light from electric pole complete all as directed by eic. note: spare parts and accessories such as led driver, and connected items etc will be measured and paid separately under respective item as supply only and fixing is deemed to be included in this item., supply only led street light driver for 45 watts led street light as per make given all as specified and directed by eic., supply only led street light driver for 60 watts led street light/ flood light type as per make given all as specified and directed by eic., supply only led street light driver for 100 watts led street light/ flood light type as per make given all as specified and directed by eic., supply and fix in repair led streetlight of 45 watt comprises of pressure die cast aluminium housing & having system efficiency>123 lumens/watt i.e 5570 lumens,all leds should be highpower leds of 1w to 3w only with modular lens for batwing shape distribution of 30 degree & 60 degree,input voltage working range is 140 vac to 270 vac,brand name should be embossed,potted driver is used with 4kv internal & external 5kv potted surge protection,short circuit protection,open circuit protection,high & low voltage protection,fixture should withstand high & low voltage protection,fixture should withstand high voltage upto440 v for 8 hr,ip66 protected,thd10%,cri>70 cct 5700+/-300k,pf>0.9,driver efficiency>85%,lm79 report required from nabl accredited lab. including taking down old unserviceable fittings and bracket house must be adjustable or if required any cost of all fixing hardware shall be included in quoted rate complete all as specified and directed by eic note : 1. engraving of ca number on each lighting fitting (street light / flood light) shall be carried out by the contractor and the cost of the same shall be deemed to be included in the quoted rate. 2. no extra payment shall be made on this account. 3.the complete fitting along with led module, driver, surge protection device and all associated accessories shall be covered under 05 (five) years comprehensive warranty by the contractor from the date of invoice.make : philips/ wipro/crompton, supply and fix in repair led streetlight of 60 watt comprises of pressure die cast aluminium housing & having system efficiency>110 lumens/watt i.e 6670 lumens,all leds should be highpower leds of 1w to 3w only with modular lens for batwing shape distribution of 30 degree & 60 degree,input voltage working range is 140 vac to 270 vac,brand name should be embossed,potted driver is used with 4kv internal & external 5kv potted surge protection,short circuit protection,open circuit protection,high & low voltage protection,fixture should withstand high & low voltage protection,fixture should withstand high voltage upto440 v for 8 hr,ip66 protected,thd10%,cri>70 cct 5700+/-300k, pf>0.9, driver efficiency>85%,lm79 report required from nabl accredited lab. including taking down old unserviceable fittings and bracket house must be adjustable or if required any cost of all fixing hardware shall be included in quoted rate complete all as specified and directed by eic. note : 1. engraving of ca number on each lighting fitting (street light / flood light) shall be carried out by the contractor and the cost of the same shall be deemed to be included in the quoted rate. 2. no extra payment shall be made on this account.3. the complete fitting along with led module, driver, surge protection device and all as

Central Government/Public Sector

CTN :45726514 Due date: 21 Jul, 202621 Jul, 2026 49.00 Lacs
Tender For repair/maint of plinth protection, hard standing, joinery, plastering, internal wiring and flame proof lighting for bomb dump and other otm bldgs of tech area at af stn gwalior.

Central Government/Public Sector

CTN :45693060 Due date: 02 Jul, 202602 Jul, 2026 2.29 Lacs
Tender For repair work of transformer and replacement of ht and lt cable, end joints god and lightening arresters at 17 bihar regt khojatoli area under ge ranchi

Central Government/Public Sector

CTN :45697300 Due date: 16 Jul, 202616 Jul, 2026 20.00 Lacs
Tender For maint of road side lighting works and miscellaneous electrical items under ge n akhnoor. - labour for cutting/pruning of tree branches along security light pole around 2 mtr radius of security light fitting and removing from site including arrangement of t&p (i.e. axe, rope & ladder etc.) complete all as specified and directed., dismantling and taking down street light fittings/post top lantern/down lighter of any wattage/size for repair or replacement of burnt/worn out accessories or carrying to mes store and refixing after repair on required location complete all as directed.note: accessories or components needed for replacement shall be measured and paid separately under appropriate items., repairing of unserviceable led street light any make/model of 90 100 watt capacity by replacing compact led electronic driver suitable to operate on 120 to 270 volt, 50/60 hz ac supply, protection grade ip-66 with surge protection complete all as specified and directed., repairing of unserviceable led street light any make/model of 60 72 watt capacity by replacing compact led electronic driver suitable to operate on 120 to 270 volt, 50/60 hz ac supply, protection grade ip-66 with surge protection complete all as specified and directed., pvc conduit medium grade of size 15 mm bore including fittings, isi marked, fixing with pcc pole/steel tubular pole/garden lights/gate lights for wiring connection from pole box to light fitting and supporting with 03 nos gi strip clamp, nut & bolt, complete all as specified and directed., replacement of pvc insulated pvc sheathed stranded copper conductor cable 2.5 sqmm twin core complete all as specified and directed., pvc insulation tape of width 18 mm, thickness 0.125 mm, length 25 mtr, isi marked, for proper insulation of joints in wire where required or directed., replacement of aluminium pvc service wire 2 core 6 sqmm flat roll of 90 mtr, superior quality, complete all as specified and directed., disconnecting & dismantling of damaged/unserviceable cable of any type/make and supply & laying in repair/replacement of cable xlpe insulated, screened pvc bedded, galvanized steel strip or wire armoured electric power cables (heavy duty), 1100 volts grade with stranded aluminium conductor using lugs/ferrules at both ends of cable and testing complete all as directed for following sizes:, 10 sqmm 4 crore, 16 sqmm 4 crore, 25 sqmm 3.5 crore, 35 sqmm 3.5 crore, note for item no. 17 & 18: excavation & earth work, sand cushioning, bricks protection & gi pipe where required shall be measured and paid separately., excavation in trenches not exceeding 1.5 mtr width and not exceeding 1.5 mtr depth, getting out for electric cable complete in any type of soil complete all as specified and directed., removing surplus excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above starting point, complete all as specified and directed., returning, filling in, soil obtained from excavation including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed., supply and laying sub class b bricks laid dry and flat across the length of cable for protection of cable complete all as specified and directed., sand cushioning with ganga sand to underground cable (8 cm thick before laying and 15 cm thick after laying the cable) complete all as specified and directed., replacement of 40 mm gi tubing light grade with all necessary fittings laid in trenches/under road crossing/fixed on pole/wall/under floor/as garden post including 2 nos mild steel fi clamps 35 3 mm size to support pipe with pole complete all as specified and directed., boring under road horizontally of size 40/50 mm bore using gi pipe for passing of cable in road/path in hard/soft/loose soil complete all as specified and directed., applying two coats of aluminium paint over a coat of red oxide on steel tubular po

CTN :45703919 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For supply of puf panels 60 mm , puf panel 40mm , pre painted galvalume aluminum zinc coating gi based corrugated steel sheet 0 point 80mm , verandah cover with aluminium partitions with 5 point 5 mm thick plain glass , ismb , hollow iron , angle or flat iron or base plate , ms sheet , tmt bars , nut and bolt , upvc door , upvc window 1200 x 1200mm , upvc ventilators 450 x 300 mm , fire extinguisher ball 1 point 30kg , curtain rod of size 1 point 30 m , steel almirah , smart ortho mattress , foot scraper , iron foot mat , white cement , looking mirror , double bunks ms tubes , floor mounted hot and cold water dispenser , bed side table , puf tank 2000 ltrs , plastic dustbins , stainless steel shoe rack , sealing material , laminated wooden floor , tactical heater diesel based , solar light , septic tank 3000 ltrs , ordinary portland cement , coarse sand , stone aggregate 20mm , stone aggregate 40mm , stone aggregate 10mm , vitrified tiles , non skid tiles , stone aggregate 63mm , mcb distribution board db 12 way , mcb sp 32 amps , mcb sp 16 amps , mcb single pole 100 amps , mcb sp 10 amps make , lt panel feeder box , die casted bulk head 8 watt , 16 amp modular switch and socket combination , 16 by 6 amp modular switch and socket combination , modular piano switch 6 amp modular switch , modular piano switch 16 amp modular switch , 16 amp modular socket , modular gang box 12 way , modular gang box 06 way , modular gang box 04 way , modular gang box 03 way , led tube light fitting 4 feet , led tube light fitting 2feet , electric geyser 25 ltr , wire flexible , 1100 v grade frls , pvc insulated unsheathed copper cable 4 sq mm , 1100 v grade pvc insulated pvc , pvc insulated unsheathed copper cable 6 sq mm , earthing , lightening arrester , gi screw 8 mm x 45 mm full threaded 500 nos , gi screw 8 mm x 25 mm full threaded 500 nos , gi screw 8 mm x 75 mm full threaded 250 nos , pvc insulation tape 19mm , cp bib cock 15 mm , cp pillar cock 15 mm , cp stop cock 15 mm , cp soap dish , cp towel rail 24 mm dia 600 mm , vitreous china ceremic floor mounted anglo indian water closet toilet seat , vitreous china bowl urinal flat back , ss garting 100mm dia , vitreous china wash hand basin , cp health faucet with fixing screw , pvc pipe 110 mm , pvc y by t junction 110mm dia , pvc socket 110 mm , pvc swr bend 110mm , pvc floor trap 75mm , pvc pipe 75mm , pvc elbow 75mm , pvc door bend 75 mm , pvc bend 75 mm , pvc shoe bend 75 mm , pvc t 75mm dia , looking mirror 450 x 600 mm , sealing thread

Central Government/Public Sector

CTN :45430604 Due date: 02 Jul, 202602 Jul, 2026 30.00 Lacs
Tender For corrigendum : repair/ maint of high mast lights, earthing, lightening arrester and allied works under ge (mcte) mhow

State Government

CTN :45660769 Due date: 10 Jul, 202610 Jul, 2026 NA
Tender For procurement of lightning materials for power houses at srhp, sikidiri. - led flood light, 120 watt, ip66, ik07, surge 10kv (as per technical specification mentioned in annexure ii of tender documents), led flood light (high surge outdoor type), 200 watt, ip66, ik08, surge 10-12 kv (as per technical specification mentioned in annexure ii of tender documents), led tubelight, 36/40 watt (as per technical specification mentioned in annexure ii of tender documents), led bulb, 9 watt (as per technical specification mentioned in annexure ii of tender documents), led bulb, 15 watt (as per technical specification mentioned in annexure ii of tender documents), led bulb, 30 watt (as per technical specification mentioned in annexure ii of tender documents), incandescent bulb, 100 watt (as per technical specification mentioned in annexure ii of tender documents), incandescent bulb, 200 watt (as per technical specification mentioned in annexure ii of tender documents), copper wire single core multistrand, 4 sq mm (as per technical specification mentioned in annexure ii of tender documents), copper wire single core multistrand, 2.5 sq mm (as per technical specification mentioned in annexure ii of tender documents), copper wire single core multistrand, 1 sq mm (as per technical specification mentioned in annexure ii of tender documents), hand lamp with 15 mtr wire, (2 x 1 sq mm) (as per technical specification mentioned in annexure ii of tender documents), halogen tube, 500 watt (as per technical specification mentioned in annexure ii of tender documents), halogen tube, 1000 watt (as per technical specification mentioned in annexure ii of tender documents), lightening arrester 11 kv (as per technical specification mentioned in annexure ii of tender documents), 80 mva digital meter, (digital temperature meter), range (300c to 1500c), model; no - 2274-t1(as per technical specification mentioned in annexure ii of tender documents), water tank (500 l) three layer (as per technical specification mentioned in annexure ii of tender documents), pvc valve (as per technical specification mentioned in annexure ii of tender documents), pvc valve 1 (as per technical specification mentioned in annexure ii of tender documents), pvc valve (as per technical specification mentioned in annexure ii of tender documents), pvc pipe 1 length - 3 mtr (as per technical specification mentioned in annexure ii of tender documents), c pvc pipe length - 3 mtr (as per technical specification mentioned in annexure ii of tender documents), pvc flexible water pipe (20 mtr) size - 1 (as per technical specification mentioned in annexure ii of tender documents), pvc thread socket (as per technical specification mentioned in annexure ii of tender documents), pvc plain socket (as per technical specification mentioned in annexure ii of tender documents), pvc connection pipe for wash basin (as per technical specification mentioned in annexure ii of tender documents)

Central Government/Public Sector

CTN :45387663 Due date: 29 Jun, 202629 Jun, 2026 9.20 Lacs
Tender For corrigendum : repair/maint/impv of building service connections, internal lighting system, led lighting and lightning protection system in various accn at jalapahar under age i darjeeling

CTN :45600061 Due date: 03 Jul, 202603 Jul, 2026 1.65 Lacs
Tender For strengthening of lightening arresters installed at the roof top of tg and bunker floor of unit 3 to 6 ktps

State Government

CTN :44994243 Due date: 29 Jun, 202629 Jun, 2026 4.93 Lacs
Tender For corrigendum : supply of lightening arrester
 Loading, Please wait...

Connect us via What's Up