Web Analytics Made Easy - StatCounter

Lightening Protection Tenders

Get complete information related to latest Lightening Protection Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lightening Protection Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lightening Protection Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45733930 Due date: 21 Jul, 202621 Jul, 2026 20.00 Lacs
Tender For repair/maintenance of earthing with maint free chemical earthing, glow sign board lightening protections and other connected work at cme under ge (cme) khadki

Central Government/Public Sector

CTN :45439198 Due date: 07 Jul, 202607 Jul, 2026 45.00 Lacs
Tender For corrigendum : ca no. ge af no.1 / gur-47 / 2026-27 repair/ maint of lightening protection system, copper strip earthing earthing, fire fightening and repair maint of meter, ups and fire alarm system along with miscellaneous repair and maint at 13 brd 16 brd

Central Government And Public Sector

CTN :45741640 Due date: 21 Jul, 202621 Jul, 2026 6.96 Lacs
Tender For purchase of 390kv surge arrestors for chamera power station-1

Central Government/Public Sector

CTN :45713895 Due date: 18 Jul, 202618 Jul, 2026 45.00 Lacs
Tender For repair/replacement of unserviceable flame proof fittings and allied maint works in tech area, unserviceable lightening protection system in tech /domestic area at dappar under age(i) dappar.

Central Government/Public Sector

CTN :45435643 Due date: 06 Jul, 202606 Jul, 2026 30.00 Lacs
Tender For corrigendum : repairs and maintenance of security lights, dg set, lightening protection, solar water system, firefighting system and other connected items at kalina and juhu under ge (n) santacruz, mumbai

CTN :45048307 Due date: 31 Jul, 202631 Jul, 2026 NA
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp

Central Government/Public Sector

CTN :45413820 Due date: 01 Jul, 202601 Jul, 2026 38.00 Lacs
Tender For corrigendum : certain miscellaneous repair/replacement works of internal electric dbs submain wiring and associated internal electrification system earthing and lightening protection system in various otm accn and adjoining unit and md quarters area at southern zone

CTN :45633951 Due date: 13 Jul, 202613 Jul, 2026 60.23 Lacs
Tender For replacement of 33kv breakers, 33kv surge arrestors, isolators, ac distribution panel and dc distribution panel at 2x50mva, 132/33 kv grid station bari brahmana-ii

Central Government/Public Sector

CTN :45639616 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For providing of custom bid for services - lightening protection system at critical locations of sub quarry 1 and sub quarry 2of agpe ocm, gpsa

corporations/Associations/Others

CTN :45260953 Due date: 26 Jun, 202626 Jun, 2026 8.14 Lacs
Tender For corrigendum : tender for supply of solar pv panel topcon - 15 kw , grid connected inverter/ power conditioning unit (pcu) alongwith built-in meter , module mounting structure (mms) , structure accessories , net meter and solar meter , array junction box , dcdb , acdb , string and jumper , earthing and cable , lighting arrestors , lighting protection system (lps) , surge protection device (spds)- surge arrestor , connectors , conduits and pipes. , dc cable for string and jumper , power cable from inverter to acdb , power cable for earthing - 15 kw , ac armored aluminum cable - 15 kw , installation , testing and commissioning - 15 kw , grid islanding protection as per nit , danger boards & signages as per nit , fire extinguishers as per nit
 Loading, Please wait...

Connect us via What's Up