Tender For supply of overhauling & maintenance of cp transformer rectifier units , ac amp. meter, for detailed description refer price breakup sheet , ac volt meter, for detailed description refer price breakup sheet , dc volt meter, for detailed description refer price breakup sheet, dc amp. meter, for detailed description refer price breakup sheet, voltmeter ( psp meter ), for detailed description refer price breakup sheet, main rectifier diodes, iav 150 amp, piv - 1200 v , type- 150 lf 120 , "lightning arrestor( la) both input and output side, rms voltage rating - 500v ,rms current rating - 1.5 ka, type- lt 0.5 oe eqv", thyrister module (scrm) consisting two antiparrallel thyrister, for detailed description refer price breakup sheet, auxiliary transformer for control circuit power supply, for detailed description refer price breakup sheet, filter capacitor bank in dc output , 2500 micro farad , 150v x 6 electrolytic capacitors, relay for providing remote contacts for mcb tripped & ac supply fail faults , coil - 240 v ac coil resistance 10 k contacts 2no+2nc , 8 pin plug in type, relay for providing remote contacts for oil tank or instrument , chamber high temp. fault. coil - 240 v ac coil resistance 10 k contacts 3no+3nc , 11 pin plug in type, thermostate with adjustable temp. setting with nc contacts ( 30 to 110 setting ), indicator lamp , housed in 22.5 mm dia, 240 v, led type red colour, auto or manual mode selector rotary type, 4 pole , 2 way ,63 amps, 240 v, ac type srpm 5417b or pa 17463b, coarse manual output control switch , rotary type, 1 pole , 6 way ,63 amps, 240 v, ac type pa7163f, fine manual output control switch rotary type, 1 pole , 4 way ,63 amps, 240 v, ac type srpm 615dor pa 5163 d, coarse current limit settor switch cam type, 2 pole ,6 way ,6 amps, 240 v, type s6-61072, fine current limit settor switch, cam type, 2 pole ,6 way ,6 amps, 240 v, type s6-61072, reference electrode selector switch, cam type 2 pole ,4 way ,6 amps, 230 v, type s6-61070, local or remote control mode selector switch,toggle type 2 pole , 2 way ,6 amps, 240 v, , on or off toggle switches in various lamp and meter circuits. 1/2 pole , 2 way ,6 amps, 240 v, , current transformer for ammeter a1 ratio - 50/1, burden - 5 va ,class - 1, contactor 32 amp.bch make 3p +(1p no) with add on 240 v ac coil , breather ( 19.45 mm dia), output voltage setter potentiometer in local auto mode 2.5 k ohm 3 watt ww, output current setter potentiometer in local auto mode 1 k ohm 3 watt ww, oil temp. indicator range ( 0 to 150 o c ), 4-20ma converter module for dc output voltage signal input - 0-75v dc , output - 4 to 20 m a , max load - 600 ohm , accuracy - +-0.5 %, aux supply - 240 v, ac type-520 t, base or channel mounting type , 4-20ma converter module for dc output current signal input - 0-75a (75 mv) dc , output - 4 to 20 m a , max load - 600 ohm , accuracy - +-0.5 %, aux supply - 240 v, ac type-520 t, base or channel mounting type , "auto transformer with coarse and fine tappings for manual control dc of output, input -265 v , coarse taps- 7 nos. fine taps- 04 nos. capacity - 8000 va, insulation - class -a (oil cooled ) ", "main transformer with shield double wound primary- 240 +/- 10 %, secondary- (0-110 v), capacity - 10,000 va, insulation - class -a (oil cooled )", filter choke in dc output , 7.5 mh at 100 amp., control box for card fixing ceco-108 & ceco 105 d1 (and extra card connector having 40 slots), current or voltage control firing card control card , type- ceco- 105d1 , "remote control interface card control card ,type- ceco -108 ", "current limit setter card control card , type- ceco -35a- 2.5 v , 75a/75mv -33.33", "voltage current sensor card control card , type -ceco -19c ", pulse driver card ceco - 118 c, surge suppressor r-c network across scrs 75 ohm, for detailed description refer price breakup sheet, "fuse fail indicator module for diodes and output fuses six channel type with led indicators and 1 common no+nc contacts ,sensing
Tender For corrigendum : supply of choke for 125watt hpmv 250v 1ph , choke for 150w hpsv lamp , choke 1ph philips/250w/hpsv/250v , choke cu for 400 watt svl cg
Tender For corrigendum : procurement of s and t spares for mgr of brbcl nabinagar c c - relay, qn1,12f/4b,24vdc,n/l code abcde, rly,qna1,8f/8b,aci dc/nl lck code-abdgh, relay, qspa1,8f/4b,24v slowpickup abdej, universal lamp relay,qecx-61,4f/4b, relay,qbca1,2f(hd)/4b,24vdc,a ci bcejk, plug-in trk relay,qta2,2f/1b,9ohm,fghkx, relay, ql1,11f/4b,24v,mag latch abdeg, fail-safe electro flasher device, relay, relay,qn1.8f/8b,24vdc,n/l, code abcdf, rly, qna1,12f/4b,aci dc/nl lck code-abdfh, led lamp shunt sgnl,w/pc lens, s&t, led unit red aspect,w/pc lens,s&t, led unit yellow aspect,w/pc lens,s&t, route indicator, led signal junction,s&t, led lamp unit calling on signal,s&t, track feed battery charger,trkckt,2-6vdc, choke coil, b-type, single rail trkckt, track fed resi disc ????,0-250hm, trk ckt
Tender For auction sale of depot miscellaneousellaneous scrap - scrap superior electrical accessories include led light fitting with frame, berth reading light fitting, ara terminal, road streeyt light, small transformer for auto charger, rotary switch, miscellaneous type of choke, hrc fuse, capacitors electronic regulators various types of mcb, mccb, lcb and its boxes, change-over, condenssor, tube light, led light, led tube light, emergency train light with or without battery dp switch train light fittings broken parts of relay, geyser element, connector, cooler tullu pump, fuse, pump, loco headlight lamp, etc with or without nf attachement, in various types and size. this scrap lot may contain other similar, known or unknown electric items, unfit for railway use, lying in godawn no. 12 [gst 18% hsn 72044900]