Web Analytics Made Easy - StatCounter

Lighting Component Tenders

Get complete information related to latest Lighting Component Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lighting Component Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lighting Component Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :40145527 Due date: 03 May, 202503 May, 2025 65.16 Lacs
Tender For providing and erecting power supply arrangement with dtc to work shop 1, 2 and 3 cctv work shops, decorative street light on work shop approach road and water supply arrangement for govt. iti dhule, tal and dist. dhule.

State Government

CTN :40114606 Due date: 29 Apr, 202529 Apr, 2025 NA
Tender For supplying and erecting solar power plant to kihim pay n park street light meter v p kihim tal alibag dist raigad

State Government

CTN :40114607 Due date: 29 Apr, 202529 Apr, 2025 NA
Tender For supplying and erecting solar power plant to kihim street light meter v p kihim tal alibag dist raigad

State Government

CTN :40114615 Due date: 29 Apr, 202529 Apr, 2025 NA
Tender For supplying and erecting solar power plant to kamath street light meter v p kihim tal alibag dist raigad

Corporations/Associations/Others

CTN :40145433 Due date: 05 May, 202505 May, 2025 NA
Tender For estimate for providing street light and on grid solar power plant at various location in the juridication of nagar parishad kanhan pipri at municipal council kanhan pimpri dist-nagpur 2 call

Central Government/Public Sector

CTN :40132710 Due date: 01 May, 202501 May, 2025 2.59 Lacs
Tender For providing electrical power points lan points wall fans replacement of old light fittings and rewiring of circuit with allied works in room no 129 aces in academic area in the campus at iit kanpur

Central Government/Public Sector

CTN :40135141 Due date: 16 May, 202516 May, 2025 36.74 Lacs
Tender For tender for supply of imecticide chlorpyriphos 10% gp to prevent insects from entering the signalling equipment. , supply of 2w/4w light weight portable control telephone to specification no. irs: tc: 78-2000 with latest amendment. , tape pvc adhesive for insulation purpose size (20mmx10mtrs) in a roll make-steel grip, pidite, or similor , supply optical power meter with visual fault locator as per specification make vaim/exfo/fluke/tempo , cat6 u/utp cable for indoor use 305 mtrs. make d-k securenet, digisol , supply of single fiber media converter optical to ethernet 1350/1550 optical & 10/100/1000 mpbs ethernet of make , mrotek/rad/cygnus/digisol/dolinic , sc to lc ofc patch cords 10 mtr long , wired computer mouse or trackballs make dell, hp, lenevo , single pair pvc drop wire of 0.91 mm.dia cadmium copper conductor , 12 v/10 amp battery charger for 25 watt vhf set as per specification copy attached , sport network switch make d-link, tp-link, tenda , supply of 24 ports un managed non poe layer 2 access , switch make tp-link, d-link, cisco , "supply of hdmi cable of 20 mtr. (high speed ultra hd), make honeywell/cable orsation/bluerigger/zebronic supply of two way counter communication system with attendant init, customer uit, power supply unit and dedicated cable for connecting the system"" ", "supply of wall & surface mount speaker, 100watt rms maka jbl begringer, blue plunk or similar supply of ofc single made de fiber unarmored cable, ", make: molex/amp/finolex/dink/policab , supply of single mode full duplex auto sensed fiber media converter as per specification, warranty 2 year , supply of lan extender with 4 port ethernet with 230v ac/48v dc working with ac power cord, as per specification no. rdsq/spn/tc/82/2020 rev. 2.0 or latest.

Central Government/Public Sector

CTN :40133308 Due date: 23 May, 202523 May, 2025 NA
Tender For specialty fiber fusion splicer-, splicer main body1 pc , cladding diameter60 to 1200 um , electrode swing , pm fiber splicing , end view fiber observation , sweep length 0 to 36 mm , dual splice loss estimation , optimal plasma zone control , observation method for fiber rotation alignmenty , usb, gpib communication , fiber holder for coating diameter250 and 400 um , fiber holder with end view observation for coating diameter250 jand 400 um , power adapter and cables , end view light source2 pc, , electrode cleaner1 , pc , dust cleaning stick1 pc , optical fiber cleaver (cladding diameter: 80 to 1250 um and cleave length: 5 to 40 mm) , adapter for fiber holder , a complete insert set compatible for coating diameter250 and 400 um , ment: technical spe

corporations/Associations/Others

CTN :40126145 Due date: 05 May, 202505 May, 2025 2.62 Lacs
Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s

corporations/Associations/Others

CTN :40126147 Due date: 05 May, 202505 May, 2025 2.62 Lacs
Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s
 Loading, Please wait...

Connect us via What's Up