Web Analytics Made Easy - StatCounter

Lighting Conductor Tenders

Get complete information related to latest Lighting Conductor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lighting Conductor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lighting Conductor Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45721639 Due date: 04 Jul, 202604 Jul, 2026 NA
Tender For supply various type construction material at gp. pilandri tal pauni dist bhandara - 80 mm. metal white-(hand broken metal) with royalty, 40 mm metal white- (hand broken metal) with royalty, 40 mm metal black- (crusher broken metal) with royalty, 20 mm metal black- (crusher broken metal) with royalty, 12 mm metal black-(crusher broken metal) with royalty, 6 mm metal black-(crusher broken metal) with royalty, boulders rubbles and masonary stones, sand river (unscreen) with royalty, sand (nallah bed), soft murum with royalty, hard murum with royalty, soil, cement 53 grade opc, cement 53 grade ppc, burnt bricks ( ii class), mild steel bars of various sizes, tmt steel bars of various sizes, oil paint isi mark, plastic emulsion paint, wall paint isi mark, centring tar, torpin oil, bitumen pack tin 60/70 at mumbai, murum carting only, weste material carting, mixter machine per day with desel and driver, water tanker with desel and driver, centring rent for drain work, centring rent for cement road, centring rent for building work, rcc pipe 1000 mm, rcc pipe 800 mm, rcc pipe 600 mm, rcc pipe 450 mm, rcc pipe 300 mm, compaction of earth work in embankment upto layer of 30cm comp machinary charges only, compaction of soft murum/ kankad 2.00 to 7.00 width (200mm loose) with static roller including necessary artificial watering etc complete, transporttion of soft murum on road side etc complete as per analysis, information board 1)size 1.20 x 0.90 , information board 2) size 0.75 x 0.90, transportation of excavated soil from ex-mat. tank to field up to 3km, wooden door frame size 6 * 3.25, cement door frame size 6*3.25, wooden door size 6 * 3.25, plywood door size 6 * 3.25, door kits per door, precost sheet, oil engine, meter stone, ferlong stone, jcb per hours, rollar per day with desel driver, griil work, murga, pavour block(gattu), quota tyles, vetryfied tyles, bt pod, wc pod, nutri trap, ms poor, ac sheet, gi sheet, distemper, birla white, in well boar 4.50 inch, in well boar 6.00 inch, epex ext. primer, epex ext. emulsion, epex interial emulsion, white putti, water tank (syntax), kadappa stone, nahani tap, fly ash brick(cement bricks), gi pipe 15 mm dia., gi pipe 20 mm dia., cpvc pipe 50 mm, cpvc pipe 25 mm, cpvc pipe 15 mm, water level indicator, lighting conductor, type coper patti, gi cd staire, pevor block (ruber quoted), pevor block color quoted, pvc lbow verious size, pvc t verious size, 25 mm pvc pipe, 250mm pvc pipe 6 kg, 250mm pvc pipe 4 kg, 200mm pvc pipe 6 kg, 200mm pvc pipe 4 kg, 110mm pvc pipe 6 kg, 110mm pvc pipe 4 kg, 90mm pvc pipe 6 kg, 90mm pvc pipe 4 kg, 75mm pvc pipe 6 kg, 75mm pvc pipe 4 kg, 63mm pvc pipe 6 kg, 63mm pvc pipe 4 kg, sluice valve 80 mm, sluice valve 125 mm, sluice valve 150 mm, sluice valve 200 mm, sluice valve 100 mm, air valve 50 mm, air valve 80 mm, air valve 50 mm, reflux valve 80 mm, gi pipe 80 mm, pvc special tee,bend,coupler,taispeace,pipe, gi special hang, nutbolt,rubber shocate, tee, bend, solution, 3 seater steel chaire, 3 seater rcc chaire, toilet sheet, pump 3 bhp 200 mm & 120 mm head, pump 5 bhp 200 mm & 120 mm head, gi bend 80 mm, gi coupller 80 mm, control panal box, steel angle, chaniling facing, primer, plywood sheet, ceramic tiles, handwash basin, tap, water meter, waterproof cement

Central Government/Public Sector

CTN :45713835 Due date: 18 Jul, 202618 Jul, 2026 30.00 Lacs
Tender For repair/replacement of external electric supply distribution network with other connected items at malad, marve and kandivali under ge (n) santacruz, mumbai - supply, install, testing & commissioning pedestal cubical type double door lt bus bar chamber box of suitable size factory made modular construction fabricated out of 3 mm thick crca sheet, angle iron, channels, epoxy powder coated to give a superior finish , outdoor type , totally enclosed dust & vermin proof with locking arrangements front & back side opening system including rain shed, busbar chamber should be suitable for accomodating all aluminium bus bar strips (50mm x 10mm x 04 nos) & gi strip for earth fixed on porcelain insulators, and one independent metering module suitable for accomodating three phase volt meters & ammeter digital type, indicator lamps, cable entry/exits cut outs at bottom part, with fixing arrangement on pcc (1:3:6) type c-2 bed block with studs, bolts, nuts & washers, danger notice board with scull suitable for 415 volts or required size to be fixed on pannel including dismantling of old bus bar panel all as specified and directed by engr-in charge.notes:-(a) aluminium bus bar duly covered with colour coded shrinkable sleeves of required size for phases and neutral - 01 set(b) mccb 4 pole , ics=100%icu- 25 ka, 415 volts, 100 amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 nos.(c) digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch and programable ct of appropriate ratio.-01 no make- imp/automatic electrical(ae)/ l&t / havells/ meco(d) panel indicating lamp neon/led type (red ,yellow & blue) with lamp holders - 03 nos(e) panel instrumental wiring with frls suitable size but not less than 2.5 sqmm copper wire single core - 01 job(f) necessary sizes of lugs for fixing of cables in bus bar deemded to be included rate quoted by the contractor.make of mccb & mcb: larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 400 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:- larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 160 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 16 ka 100 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 250 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb all as specified and directed by engr-in-charge make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supplying, laying,connecting, testing & commissioning lt ug pvc insulated, heavy duty, 1100 v grade electric cable with aluminium conductor of size 16 sqmm x 4 core, laid in trenches or passing through pipe or fixed to wall, making all connections with and including provision of necessary glands, lugs, bushing etc as required including taking down old unserviceable cable complete all as specified and as directed by engineer-in-charge of following sizes:-note : earthwork excavation, dwc

Central Government/Public Sector

CTN :45475154 Due date: 07 Jul, 202607 Jul, 2026 30.00 Lacs
Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get

Central Government/Public Sector

CTN :45719686 Due date: 13 Jul, 202613 Jul, 2026 44.90 Lacs
Tender For repair/ maint of lt ug cables and its connected items of masimpur mil stn incl army est at khumbigram under masimpur mil stn - e & m division items, dismantling of old unserviceable/damaged acsr or aac conductors of any size , jumper from overhead line & stacking serviceable & non serviceable material separately complete all as specified and directed., dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of pcc and removing unserviceable meterials from site of work complete all as specified and directed., dismantling of cross-arms of ms channel or angle of any sections complete all as specified and directed., dismantling of insulators of any size/type complete all as specified and directed., dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed, excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed., returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed., removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed., supply and laying burnt bricks of sub-class b of size 230mm x 115mm x 75mm laid in trenches for cable protection complete all as specified and as directed, supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. note: thickness of sand cushioning after punning down will be measured and paid separately., m&l for cutting existing road / pcc drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with pcc 1:3:6 type ci using 20mm graded aggregates complete all as specified, taking down or out existing cable of sizes 10 sqmm to 70 sqmm 2/3.5/4 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, taking down or out existing cable of sizes 95 sqmm to 300 sqmm 3.5 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :-(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 10 to 70 sqmm 2/3.5/4 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified. note :- lugs and glands will be measured and paid separately., relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 95 to 300 sqmm 3.5 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc compl

Central Government/Public Sector

CTN :45719626 Due date: 18 Jul, 202618 Jul, 2026 40.00 Lacs
Tender For repair/ replacement of lt cable, lt panel and connected items in domestic area (excluding camp area), su site 1a and 1b at af stn jodhpur - excavating in trenches n. exc. 1.5 m wide and n. exc. 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc 10 sqm on plan and getting out in soft/ loose soil complete all as specified and directed., returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in any type of soil.complete all as specified and directed., removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in any type of soils.complete all as specified and directed., m&l for sand cushioning for xlpe cable with tibba sand (one layer of 80mm thickness before laying of cable and other layer of 150mm thickness after laying of cable) and punning down to 180mm to provide a required cover complete all as specified and directed by the engineer-in-charge.note:- punned thickness only shall be measured and paid., m&l for protection to cable with one layer of bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class b bricks complete all as specified and directed by engr-in-charge., supplying and laying un-reinforced precast concrete cable cover, class lv, type i, flat, size 250mm x 150mm x 40mm confirming to is - 5820 complete all as specified and as directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm, 4 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm, 4 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 95 sqmm, 3.5 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 150 sqmm, 3.5 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable, laid in ground with aluminium conductor, 1100 volts grade, cross-sectional area 240 sqmm, 3.5 core complete all as specified and directed., taking down of lt cable any size from trech/ gi pipe/ walls/ on ground/ street light poles complete all as specified and directed., m&l for boring of holes under road, pavement, hard stansding by using manual method with 100mm hdpe pipe complete all as specified and directed by engineer-in-charge., s&f in repair mccb 400 amp, 4 pole, 415 v, 36 ka, thermal megnatic adjustable type complete all as specified and directed., s&f in repair mccb 250 amp, 4 pole, 415 v, 35 ka, thermal megnatic adjustab

Central Government/Public Sector

CTN :45707597 Due date: 17 Jul, 202617 Jul, 2026 45.00 Lacs
Tender For repair and replacement of unserviceable parts of dg set, corroded panel, repair of earthing strips, unserviceable sign board, lighting conductor, pcc works, stp and rewinding of motors including allied works at bagrakote mil stn under ge sevoke road

Central Government/Public Sector

CTN :45425477 Due date: 06 Jul, 202606 Jul, 2026 47.30 Lacs
Tender For corrigendum : special repair /replacement of over head acsr conductor with ug cable lt panels and connected items of stn hq , hq cwe dinjan and hq cce area under ge dinjan

CTN :45737971 Due date: 11 Jul, 202611 Jul, 2026 NA
Tender For supply of combined 5 pin 15 amp , bell switch 5 amp , pvc switch and socket combine with board 15 by 16 amp , pvc switch and socket combine with board 5 by 6 amp , distilled water , combination plier , cutting plier , screw driver set , ceiling led light , 2 pole mcb 10 ampcomma 220 volt , 2 pole mcb 16 ampcomma 220 volt , 2 pole mcb 32 ampcomma 220 volt , 2 pole mcb 64 ampcomma 220 volt , 0point5 hp water pump , car air pressure pump , 16 amp switch , 16 amp socket , mcb 2 pole 20 amp , 4 into 7 pvc board gangbox , 12 into 12 pvc board gangbox , 4 into 4 pvc board gangbox , 6 amp socket , main switch 63 amp , cable 2 core roll of 91 mtr 6 sqmm aluminium , change over switch 400 amp 3 phase 4 pole , 200 amp cut off fuse , 200 amp 3 pole mcb , mcb 63 ampcomma 220 volt , cable 2 core roll of 91 mtr 10 sqmm aluminium , main switch 100 amp , xlpe three core 50 sq mm aluminium unarmoured power cable 1 point 1 kv , cable 2 core roll of 91 mtr 16 sqmm aluminium , earthing set meter tester , earthing wire single core 1point5 sq mm , line tester , bulb holder , red indicator light for electric board , cable 2 core roll of 91 mtr 2point5 sqmm , kit kat fuse box 3 pole , xlpe two core 50 sq mm aluminium unarmoured power cable 1 point 1 kv , xlpe four core 25 sq mm aluminium unarmoured power cable 1 point 1 kv , xlpe two core 25 sq mm aluminium unarmoured power cable 1 point 1 kv , xlpe two core 16 sq mm aluminium unarmoured power cable 1point1 kv , 100 amp 415 volt busbar chamber board with 100a four pole isolator protection , mccb 415 volt 3 phase 100 amp , mcb box 8 way , gi tubular pole 100 mm dia length 5 mtr thickness 4 mm with baseplate 250mm x 250mm as per is 2713 part 1 and part 3 , aluminium lug 50 mm , aluminium lug 10 mm , aluminium lug 25 mm , gi nut and bolt size m 10 length 50 mm full thread , charcoal , salt , earthing plate 2 feet into 2 feet into 8 mm , gi wire 6 mm , winding wire , cable tie lock belt 6 feet feet , main switch box 4 pole 3 phase 200 amp , exhaust fan 9 feet feet 30 watt , screw size 1 feet feet , bed switch size 6 amp 220 volt , batton holder 06 amp 220 volt , pendant holder 06 amp 220 volt , lighting conductor rod , hydrometer for specific gravity , drill machine set battery , change over switch 32 amp single phase 2 pole , kit kat fuse switch gears , extension board of 02 capacity , ampere meter , double core wire 8 sq mm , double core wire 16 sq mm , double core wire 25 sq mm , digital clamp meter , dc test lamp automatic circuit tester , multistrand electrical wire 2 sq mm pvc single core , tulu pump 1 to 1 point 5 hp , pvc gang box 4 into 2 , pvc gang box 2 into 2 5 pin socket 5 amp, switch 5 amp, 3 pin plug 15 amp, 3 pin plug 05 amp, modular switch board (4 switch, 1 socket), modular switch board (6 switch, 1 socket), modular switch board (8 switch, 2 socket), 1 switch + 1 socket smart switch board , 4 switch + 1 socket smart switch board , 6 switch + 2 socket smart switch board , 8 switch + 2 socket smart switch board , cable four core 10 sq mm , cable 2 core roll of 91 mtr 10 sqmm, cable 2 core roll of 91 mtr 6 sqmm , multistrand electrical wire 6.0 sq mm pvc single core, multistrand electrical wire 4.0 sq mm pvc single core, multistrand electrical wire 2.5 sq mm pvc single core, multistrand electrical wire 1.5 sq mm pvc single core, multistrand electrical wire 1.0 sq mm pvc single core, multistrand electrical wire 0.75 sq mm pvc single core, casing and caping 20 mm (length of 3 mtr), casing and caping 25 mm (length of 3 mtr), led bulb 20/24 watt, //bid details 2 / 94

Central Government/Public Sector

CTN :45719683 Due date: 13 Jul, 202613 Jul, 2026 44.60 Lacs
Tender For repair/ maint incl conversion of existing overhead lt acsr cable to underground cable and miscellaneous maint services such as replacement of poles, acsr conductor cross arms in masimpur mil stn incl army est at kumbhigram under masimpur mil stn

Central Government/Public Sector

CTN :45382837 Due date: 04 Jul, 202604 Jul, 2026 NA
Tender For corrigendum : repair/maint of external electric supply system, distribution lt panels with connected items and allied services at other than basistha area under ge guwahati. - excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of under ground cable, pole or stay and getting out in soft soil strata complete all as specified and as directed., returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as specified and as directed., removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed., supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (note : punned thickness shall be measured)., m&l for bricks common burnt clay, building brick, sub class b designation 75 old size bricks laid in trenches flat over sand cushioning for cable protection complete all as specified and as directed., m&l for supply and fixing / laying in replacement, connect, test and commissioning of lt under ground cable xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of ms saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed.note : manufacturers test certificate shall be submitted alongwith rar/fb to engr-in-charge., (a) 95 sqmm x 3.5 core, (b) 70 sqmm x 3.5 core, (c) 50 sqmm x 3.5 core, (d) 25 sqmm x 3.5 core, supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 630 amps, 50ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 400 amps, 36 ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 250amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 160amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 125 amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 100amps, 26ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 63amps, 16 ka breaking
 Loading, Please wait...

Connect us via What's Up