Get complete information related to latest Lighting Spare Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lighting Spare Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lighting Spare Tenders.
Tender For supply of contactor 415 v ac, 50 a, 50 hz, motor rating 22 kw, auxiliary contacts: 2 no +2 nc of star delta starter for radiator fan motor fitted in lhb power car. material shall be as per m/s siemens part no 3rt2036-1al20 or equivalent part of m/s schneider or abb or equivalent as per rcf spec no edts 114 rev-b. [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : providing material for annual comprehensive maintenance of 500 kva diesel generator set sudhir kirloskar make in dr. rkgmc hospital hamirpur distt. hamirpur) - supplying and fixing of kirloskar care premium genuine oil 50 liters can s, supplying and fixing of kirloskar care premium genuine oil 5 liters can , supplying of lube oil filter-full flow-spin on kirloskar logo reversal application, supplying and fixing of lube oil filter by pass spin on, supplying and fixing of final filter cartridge, supplying and fixing of 6h 508 06 0 pr cartridge for filter 6h 508 04 0 pr e08368990, supplying and fixing of urea filter , "supplying and fixing of suction connection piece", supplying and fixing of adblue inlet line filter, supplying and fixing of kirloskar care genuine coolant premix 26 litres can, supplying and fixing of air filter primary, supplying and fixing of air filter safety, "supplying and fixing of genuine d.e.f. 20 litre can", supplyingand fixing of freight charges, providing contactor for 62.5 kva dg set with add on block including vmr 3 pin relay with five year warranty .make:-l& t/schneider /hager as approved by engineer -in charge.
Tender For supply of contact fixed & moving for contactor type cbc 45a 320z (c118) specification :- mgs drg.no.- asc.e2.04.2018.16 clw specno. clw/es/c-15/d [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of contactor (with diode) conforming to iec : 60497 for ventilation fan motor in lhb coaches of current rating 9 a, ac3 voltage rating 415 volts ac; main pole 3 no; auxiliary contact 1 nc, control voltage 77 to 143 volt dc with surge suppressor of type / make: tal9-30-01-62+rt5/150 of abb or lc1-d09fd of schneider or 3rt2016-1bf42 + 3rt2916-1jl00 of siemens as per rdso specificationno. rdso/pe/spec/ac/0184-2015 rev. 0. offers from oem or their authorized dealers will only accepted. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of 3 pole power contactor, rated current- 110a, coil voltage- 415v,50 hz with 2 no plus 2 nc, rated power- 76 kw, ac 3 , 3 pole power contactor, rated current- 32a, coil voltage- 415v,50 hz with 2 no plus 2 nc, rated power- 21 kw, ac 3 , 3 pole power contactor, rated current- 22a, coil voltage- 415v,50 hz with 2 no plus 2 nc, rated power- 11 kw, ac 3 , 3 pole power contactor, rated current- 16a, coil voltage- 415v,50 hz with 2 no plus 2 nc, rated power- 09 kw, ac 3 , 3 pole power contactor, rated current- 63a, coil voltage- 415v,50 hz with 2 no plus 2 nc, rated power- 41 kw, ac 3
Tender For corrigendum : e-tender for rate contract for supply of electrical items - closing release, uc release -, universal motor for breaker spring charge, shunt release, l.a.f.a.p ,for castell lock: u-power, micro switch for spring charging, kwh meter, kwh meter, led a meter, led a meter, led volt meter, maximum demand controller, phase loss + phase sequence (smr), aux. contactor with ac coil, aux. contactor with ac coil, emergency stop button, modular , no contact block, selector switch, white led indicating lamp, blue led indicating lamp, green led indicating lamp, yellow led indicating lamp, amber led indicating lamp, red led indicating lamp, white led indicating lamp, blue led indicating lamp, green led indicating lamp, yellow led indicating lamp, amber led indicating lamp, red led indicating lamp, hotter, 230v ac, neutral link, control terminals, 1pole ac instantaneous high stability circulating current relay, micro processor based release, acc spreader terminal, aux contact, extended rotary handle, microprocessor based released, acc spreader terminal, microprocessor based released, acc spreader terminal, mccb with ti release, microprocessor based released, aux contactor with dc coil, timer, mccb with mp based release, extended rotary handle for above mccb, panel door mounted key lock for extended rotary handle, ct shorting terminals, closing release, uc release -, universal motor for breaker spring charge, shunt release, l.a.f.a.p ,for castell lock: u-power, micro switch for spring charging, kwh meter, kwh meter, led a meter, led a meter, led volt meter, maximum demand controller, phase loss + phase sequence (smr), aux. contactor with ac coil, aux. contactor with ac coil, emergency stop button, modular , no contact block, selector switch, white led indicating lamp, blue led indicating lamp, green led indicating lamp, yellow led indicating lamp, amber led indicating lamp, red led indicating lamp, white led indicating lamp, blue led indicating lamp, green led indicating lamp, yellow led indicating lamp, amber led indicating lamp, red led indicating lamp, hotter, 230v ac, neutral link, control terminals, 1pole ac instantaneous high stability circulating current relay, micro processor based release, acc spreader terminal, aux contact, extended rotary handle, microprocessor based released, acc spreader terminal, microprocessor based released, acc spreader terminal, mccb with ti release, microprocessor based released, aux contactor with dc coil, timer, mccb with mp based release, extended rotary handle for above mccb, panel door mounted key lock for extended rotary handle, ct shorting terminals
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c-423; l006 during boat davit operation smoke observed from control transformer in control panel of boat davit and abnormal noise observed from hoisting gearbox lim..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c-423; l013 port blower of water jet compartment is not getting start zero insulation measured suspected winding burnt defect to be identified and rectified and sys..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c-423; l022 smoke observed from ac control panel during operation di dr carried out by ss and observed contactor coil and no nc switch burnt out contactor coil and..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c-423; l 023 main engine control battery charger is non operational defect identification carried out by ss and observed that control pcb is burnt same to be repair..
Tender For geafu-40/2026-27 repair/ maintenance of d.g set/amf panel/auto transformer switch/ contactor/ relay/ changeover switches/ control panel of diesel generator set and certain miscellaneous work at af stn nathatop under ge (af) udhampur