Get complete information related to latest Lighting Transformer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lighting Transformer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lighting Transformer Tenders.
Tender For corrigendum : tender for supply of equipment material design erection testing commissioning for sop to ms shyam indus pvt ltd co prittam singh at vill baghni by prov 1104kv 25kva sstn aw 3ph lt line in vill baghni in e section bhadwar under esd hpsebl nurpur. t - 25 kva trsanformer, prov. distribution transformer (ordinary), 11/0.4 kv, 25 kva ., prov. steel tubular poles (9 m, working load > 200 kgf/m ) ., prov. muffs with concerete filling, prov. x-arm: [channel iron (100x50x6 mm), length : 2800 mm x 2 nos] for incomer line, prov. ms angle iron (50x50x6 mm), length: (2800 mm) x1 nos for las, prov. x-arm: [channel iron (75x40x6 mm), length : (2800 mm x 4 nos] for supporting do fuse unit & go switch, prov. transformer bed, belting & knee bracing, prov. x-arm: [channel iron (100x50x6 mm), length : 2800 mm x 2 nos] for transformer bed, prov. x-arm [channel iron (100x50x6 mm), length : (460 mm) x 2 nos for supporting main channel of transformer], prov. ms angle iron (50x50x6 mm), length : (2800 mm) x 2 nos, prov. ms angle iron (35x35x5 mm), length : (460 ) x 2 nos, prov. ms angle iron (50x50x6 mm), length : (950 mm) x 2 nos for bed knee bracing, prov. transformer lt distribution box and go switch fixing assembly, prov. ms angle iron (50x50x6 mm), length : (2800 mm) x 2 nos, prov. ms angle iron (50x50x6 mm), length : (450 mm) x 1 nos, prov. go switch handle supporting: [channel iron (75x40x6 mm), length : 460 mm, prov. go ab switch unit (11kv, 400a, 25 ka ) tripple pole o/d type, prov. d.o fuse unit, prov. lighting arrester, 9 kv station class (porcelain type), prov. discs insulator sets (comprising 1 no. disc: ^^(porcelain, bs, 12 kv, 90 kn) including dead end clamps etc.), prov. stay set complete, prov. stay wire (7/3.15 mm) (6.0 kg per stay set), prov. pipe earthing set, prov. lt distribution panel box with mccb(160a, 10ka, 4p, 1no) & sfu(32a, 5no, rewirable), prov. half clamp (m.s. flat 50x6 mm), prov. full clamps (m.s. flat 50x6 mm), prov. nuts and bolts of various sizes (galvanised / coated) [preferably 16 mm or more (with flat and spring washers)], prov. aluminium thimble, prov. copper thimble 35 amp, prov. danger plate, prov. barbed wire, prov. lt cable (3.5 core) 50 mm , prov. energy meter 3- , 4 wire ct operated static tri-vector meter with box(ct-100a), prov. aluminum paint., prov. 6/1/3.35, 50mm ., prov. construction of foundation of transformer, erection of 25 kva s/stn. i.e. digging of pit for pole & earthing two no. poles & 3 nos. for earth drilling of holes in x-arms, preparation of plateform str. members c.i., a.l. i.e. x-arms & k.b. set, errection of d/p, concreating of rcc muff errection of plateform, errection of x-arms, d.o., l.a., mccb, switch lt box, energy meter, errection of transformer, earthing connection to g.o. switch, transformer l.a. etc., errection of stay set, jumper, pipe earthing 3 nos set, l.t. cable, barbed wire and painting complete in all respect., transportation charges @10490/-, prov. transportation charges & mannual carriage of 25 kva pole mounted distribution s/stn. (line length 0.500km), erection of 3- ph. lt line, prov. aaac (7/3.15 50mm ) { neutral conductor including 1% (sag, jumpering and wastage}, prov. steel tubular poles (8 m, working load > 200 kgf/m )., prov. muffs with concerete filling, prov. shackle insulator with d-iron, prov. lt stay set i/c egg insulator., prov. nuts and bolts of various sizes (galvanised / coated) [preferably 16 mm or more (with flat and spring washers)], prov. stay wire, prov. g.i wire no 8swg, erection of 8 mtr. st pole single structure i.e. digging of pit, fixing of insulator, x-arms, k.b. set, top clamp, barbed wire, danger plate, drilling of holes and filling of pit + ramming complete in all respect., sagging of conductor i.e. laying, stringing and sagging & binding with insulator (single wire per km)., sagging of g.i i.e. laying, stringing and sagging & binding with insulator (single wire per km)., erection of stay
Tender For corrigendum : supply of carriage of distribution transformer 25 kva from esc mnp , carriage of distribution transformer 63 kva from esc mnp , carriage of distribution transformer 100 kva from esc mnp , carriage of distribution transformer 250 kva from esc mnp , carriage of acsr weasel conductor from esc mnp , carriage of m s earthing rod 20 x2540 mm from esc mnp , carriage of lt al. xlpe cable size 1x240 sq.mm. from esc mnp , carriage of lt xlpe cable 1x120 sq.mm. for dtr from esc mnp , carriage of lt xlpe cable 1x400 sq.mm. for dtr from esc mnp , carriage of lt xlpe cable size 3.5x70 or 35 sq.mm. from esc mnp , carriage of lt ab cable 3x120 1x95 1x16 sq.mm. from esc mnp , carriage of lt ab cable 3x50 1x35 1x16 sq.mm. from esc mnp , carriage of lt ab cable 3x95 1x70 1x16 sq.mm. from esc mnp , carriage of 33 kv xlpe cable 3x300 sq.mm. from esc mnp , carriage of 33 kv indoor or outdoor jointing kit size 3x300 sq.mm. from esc mnp , carriage of 33 kv straight through size 3x300 sq.mm. from esc mnp , carriage of g.i. wire 6 or 8 swg for guarding from esc mnp , carriage of three phase distribution box from esc mnp , erection of fixing of lt fuse set protection box with all respective accessories as per norms , execution of chemical earthing with g.i. patti clamp nut and bolts as per norms , erection of l.t. tail less unit with all respective material as grouted angel with fabrication work etc. , laying of acsr weasel conductor , laying of lt ab cable 3x120 1x95 1x16 sq.mm. , laying of lt ab cable 3x50 1x35 1x16 sq.mm. , laying of lt ab cable 3x95 1x70 1x16 sq.mm. , mounting of three phase distribution box , erection of double pole structure 8.5 mtr pcc pole , erection of single pole structure 8.5 mtrs pcc pole , erection of tri pole structure 33 kv 13 mtr st pole , grouting of pcc or stp pole , grouting of stay , earthing of pole , guarding of 11 kv line , fencing of 250 kva distribution transformers , plinth for 250 kva transformer , installation of 11by0.4 kv tf 25 kva , installation of 11by0.4 kv tf 63 kva , installation of 11by0.4 kv tf 100 kva , installation of 11by0.4 kv tf 250 kva , laying of 33 kv xlpe cable 3x300 sq.mm. , installation of 33 kv indoor or outdoor jointing kit size 3x300 sq.mm. as per norms. , dismentlling, received back and safe carriage of jarjar g.i. wire and weasel conducter including with rolling from pit site to esc, mainpuri , received back of distribution transformer after increasing capacity from pit site to esc, mainpuri
Tender For technical bid for supply of hvac operational spares , bearing (6206) size: od, 60 mm x id 50 mm ball bearing desig: 6001-z, ball bearing desig: 6307/2z c3 universal hvac/r controller, armoured 4 core x 6 sqmm xlpe copper cable. 1 sqmm frls multi stranded copper cable (single wire), 10 sqmm frls multi stranded copper cable (single wire) 4 sqmm frls multi stranded copper cable (single wire), fibre glass insulated copper wire for heater size: 6 sqmm, alkaline battery volt: 9vf sealed maintenance free (smf) lean-acid battery 7ah 12v, brush width: 3 inch for painting work. loctite 495 adhesive, kiwi drain cleaner heavy duty industrial safety gloves - cut-resistant (mechanical work), spray foam insulation (pfu) can qty: 750 ml wd 40 multipurpose spray size: 500 ml, green paint (bus green synthetic enamel black paint (synthetic enamel), ms flat bar size: 40 x 5 mm ms l- angle size: 25 x 25 x 5 mm, ms l- angle size: 40 x 40 x 5 mm metal primer (red oxide), black color spary paint 400 ml thread repair helicoil insert ss-m18 x 2.5mm x 1.5d, thread repair helicoil insert ss-m20 x 2.5mm x 1.5d thread repair helicoil, insert ss-m24 x 3mm x 1.5d thinner for oil-based paints, wire type buffing whee bench grinder wheel -heavy grade, dial test indicator (dti) gauge with flexible stem magnetic base stand, digital clamp meter capacity: 600a ac trms heavy duty exhaust fan, size: 9 inch backward curved fan with motor size: 355, mm dia ventilation fan for electrical panel sweep, dia: 12 cm induction motor fan, blade shaft size: 20 mm & blade dia: 130 mm, induction motor fan blade shaft size: 25 mm, & blade dia: 110 mm gi 6 mm x 25 mm bolt & nut with washer, anchor bolt with nut & washer size: 10 mm anchor bolt with nut &, washer size: 8 mm anchor fastner size: 10, mm for threaded rod gi self tapping screw, size: 3/4 inch (20 mm) head type: truss, pop screw size: 1 inch (25 mm) head type: flat (csk). ss self tapping screw size: 2 inch (50 mm), head type: hex din rail size: 35 x 7.5 mm, add on auxiliary contact block (1 no +1 nc) casing and capping size: 20mm (3/4 inch), casing and capping size: 50mm (2 inch) copper strip for electrical motor size: 25 x 3 mm, current transformer (for mfm/ammeter), ratio: 10/5a current transformer (for mfm/ammeter), ratio: 15/5a, current transformer (for mfm/ammeter), ratio: 20/5a current transformer (for mfm/ammeter), ratio: 30/5a, current transformer (for mfm/ammeter), ratio: 5/5a emergency stop switch, metal enclosure electrical junction box, size: 200mmx200mmx150mm, metal enclosure electrical junction box size:, 300mmx300mmx200mm three pole neutral (4p), 32 amps miniature circuit breaker (mcb) 4-way mcb metal enclosure, 2- module surface mounted pvc box. thermal overload relay, range: 14-23 amps electronic fan regulator, single module porcelain heater insulators or terminal. blocks, led indicator color: amber pin type lug size: 1.5 sqmm, pin type lug size: 2.5 sqmm pin type lug size: 4 sqmm, pin type lug size: 6 sqmm spade type lug size: 1.5 sqmm, spade type lug size: 2.5 sqmm metal flexible conduit size:19, motor protection circuit breaker (mpcb) range: 6.3-10 amps (rotary) motor protection circuit breaker (mpcb) inst trip rating: 2.5 amps (rotary), motor protection circuit breaker (mpcb) inst trip rating: 25 amps (rotary) motor protection circuit breaker (mpcb) inst trip rating: 50 amps (rotary), ms conduit size: 25 mm motor terminal block range: 10 hp/7.5 kw, motor terminal block range: 40 hp/30 kw thermal overload relay(olr) range: 20-33 amps, thermal overload relay(olr) range: 42-69 amps plug top 3 pin capacity: 5 amps, 4 pole power contactor capacity: mnx 12 4 pole power contactor capacity: mnx 18, 4 pole power contactor capacity: mnx 9 push button (illuminated) color: green, push button (illuminated) color: red plugable interface relay (4 c/o, 230 vac) with base, plugable interface relay (4 c/o, 24 vac) with base analog timer controller for split ac's, terminal block range: 0.2-2.5 sqmm,
Tender For supply of 9kva, 750v ac/415v ac/190v ac, 3-phase, dry type distribution transformer for lhb type non-ac coaches., as per drawing: rdso/pe/spec/tl/0158-2010,rev-0,type-i with edml 225, rev-0 & rcf corr-1., packing instruction: alternator,rru, erru &accessories, transformer,bulkinverters , battery, charger, self priming monoblock pump, inverter, change over control box etc: suitably covered with biodegradable transparent polythene and packed in wooden cage: bottom frame to be made of wooden planks 20mm thick &should have support of at least 3 wooden battons of size 100x100mm of suitable length to facilitate lifting by fork lifter. each panel to be packed in wooden cage of suitable dimensions made out of wooden strips of 20x100mm size. gap between each strip should not be more then 100mm. the material used for product packaging shall be eco-friendly.a list should be pasted on each wooden cage showing order no, pl no, description of the item, drg. no/ spec. no ,qty, firm's name &address and date of despatch etc. note- 1) firms have option to provide qr code. for linkage ofpo, the cardboard box shall carry a qr code having details as listed below: a) name of the manufacturer b) purchaseorder number c) purchaseorder date d) uniqueserial number (or lot number for bulk items) of the manufacturer or e) dateof manufacture f) deliverychallan no. g) deliverychallan date 2.the qr code shall be as per iso/iec 18004 model2 and thedata shall be available as xml using the tags detailed above. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of smoke detector unit for power car, as per drawing: edts-087, rev-b, corr 1&2with rcf annexure -br-01, packing instruction: alternator,rru, erru &accessories, transformer,bulk inverters , battery, charger, self priming monoblock pump, inverter, change over control box etc: suitably covered with biodegradable transparent polythene and packed in wooden cage: bottom frame to be made of wooden planks 20mm thick &should have support of at least 3 wooden battons of size 100x100mm of suitable length to facilitate lifting by fork lifter. each panel to be packed in wooden cage of suitable dimensions made out of wooden strips of 20x100mm size. gap between each strip should notbe more then 100mm. the material used for product packaging shall be eco-friendly.a list should be pasted on each wooden cage showing order no, pl no, description of the item, drg. no/ spec. no ,qty, firm's name &address and date of despatch etc. note- 1) firms have option to provide qr code. for linkage of po, the cardboard box shall carry a qr code having details as listed below: a) name of the manufacturer b) purchaseorder number c) purchaseorder date d) uniqueserial number (or lot number for bulk items) of the manufacturer or e) dateof manufacture f) deliverychallan no. g) deliverychallan date 2.the qr code shall be as per iso/iec 18004 model2 and the data shall be available as xml using the tags detailed above. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For distribution transformer of rating 250 kva, 11kv/415v-240v, 3-phase, 50hz, outdoor type, plinth mounted, the type of tap changer: off-load tap changer for variation of hv voltage from +5% to -10% in steps of 2.5%, energy efficiency level 3 or better, oil immersed, non-sealed type (transformer tank body and cover are bolted), copper wound, primary winding in delta and secondary winding in star (vector symbol- dyn11), onan cooled transformer, conforming to is 1180 (part 1):2014 with amendment nos. 1,2,3,4 or latest, and supplied with all standard fittings mentioned in clause 20.1 of is 1180 (part 1) latest withcondition that drain-cum-sampling valve will be applicable for all capacity of transformers. oil temperature indicator & winding temperature indicators will be provided as per clause 20.2 f) of is 1180 (part 1). terminal arrangement: the transformers shall be fitted on high voltage and low voltage sides with outdoor type bushings of appropriate voltage and current ratings. the high voltage bushings (3 nos.) shall conform to is/iec 60137. the low voltage bushings (4 nos.) shall conform to is 7421. suitable cable-end box along with cable entry hole glands is to be provided at l.t. side. following has to be submitted by supplier along with supply of material: (i) type test report of transformer having same rating, make (& model if any) and design from nabl accredited lab as per is: 1180 (part 1) latest. (ii) routine test certificates as per is: 1180 (part 1) latest. (iii) special test certificates as per clause 21.4 sl. no. (a), (c), (d) & (e) of is: 1180 (part 1) latest. detailed specification attached as annexure a. [ warranty period: 30 months after the date of delivery ]]
Tender For supply & testing of 500 kva, 11kv/750v, 3-phase, 50 hz. outdoor type power transformer conforming to 15 2026 (part 1): 2011 (reaffirmed 2021), plinth mounted, copper wound, mineral oil immersed with freely breathing system (also called conservator system) as per clause 8.2 (a) of is 2026 (part 1), primary winding in delta and secondary winding in star (vector symbol-dyn11), onan cooled transformer, minimum short circuit impedance of 5% as per is 2026 (part 5), with all fittings specified in annexure a to this description, terminal arrangement: the transformers shall be fitted on high voltage and low voltage sides with outdoor type bushings of appropriate voltage and current ratings. the high voltage bushings (3 nos.) shall confirm to is/iec 60137. the low voltage bushings (4) nos.) shall conform to 15.7421. suitable cable-end box is to be provided as follows: a) for outdoor type: l.t. side tap changer: on-load tap changerfor variation of hv voltage from -+5% to -5% in steps of 1.25% make- andrew yule/aeg/crompton greaves/kirloskar electric co./abb/siemens/schneider or similar. [ warranty period: 30 months after the date of delivery ] ]