Web Analytics Made Easy - StatCounter

Lighting Work Tenders

Get complete information related to latest Lighting Work Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lighting Work Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lighting Work Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45494426 Due date: 19 Jun, 202619 Jun, 2026 29.99 Lacs
Tender For special repair no 05 - erection, maintenance and dismentalling work of overhead ht lt line, tc & ht lt ab cable under samkhiyali sub division under bhachau division

State Government

CTN :45494427 Due date: 19 Jun, 202619 Jun, 2026 29.99 Lacs
Tender For special repair no 04 - erection, maintenance and dismentalling work of overhead ht lt line, tc & ht lt ab cable under rapar sub division under bhachau division

State Government

CTN :45494428 Due date: 19 Jun, 202619 Jun, 2026 29.99 Lacs
Tender For special repair no 03 - erection, maintenance and dismentalling work of overhead ht lt line, tc & ht lt ab cable under bhimasar sub division under bhachau division

State Government

CTN :45494429 Due date: 19 Jun, 202619 Jun, 2026 29.99 Lacs
Tender For special repair no 02 - erection, maintenance and dismentalling work of overhead ht lt line, tc & ht lt ab cable under balasar sub division under bhachau division

Central Government/Public Sector

CTN :45482004 Due date: 29 Jun, 202629 Jun, 2026 40.90 Lacs
Location: Goa - Goa Goa - Goa
Tender For repair/ maintenance of lt ug cable and replacement of old unserviceable lt ug cable and connected works at ins mandovi under ge (p) navy mandovi

Central Government/Public Sector

CTN :45160703 Due date: 15 Jun, 202615 Jun, 2026 47.94 Lacs
Tender For corrigendum : special repair to ug water sump of old pump house rcc oh tank at arf filter house and replacement of lt panel board oh to ug cable and allied work at main water supply installation under age em and age br ii of ge bengdubi

Central Government/Public Sector

CTN :45254236 Due date: 16 Jun, 202616 Jun, 2026 NA
Tender For corrigendum : repair/replacement of lt ug cable /lt outdoor panels maintenance to e/m installation/sub station, diesel generator set installation and connected works at hqtc bangalore

Central Government/Public Sector

CTN :45491100 Due date: 30 Jun, 202630 Jun, 2026 49.00 Lacs
Tender For repair and replacement of lt cable and street light fittings and garden light and post top lantern and hightmast lights and connected accessories under ge dipatoli

Central Government/Public Sector

CTN :45475154 Due date: 30 Jun, 202630 Jun, 2026 30.00 Lacs
Tender For repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and getting out in an

Central Government/Public Sector

CTN :45491112 Due date: 30 Jun, 202630 Jun, 2026 22.34 Lacs
Tender For special repair of lt over head line to lt ug cable at cod me line under ge dehu road
 Loading, Please wait...

Connect us via What's Up