Tender For maintenance of electrical installation & fans and pumps i/c compound light, sub station equipment, dg set, fire fighting, wet riser sprinkler system, fire alarm, pa system, lifts, dumb waiter and air conditioning plant at national medical library, ansari nagar, new delhi(sitc of lt panel & miscellaneous fire fighting works.)
Tender For supply, installation, testing & commissioning of 100% hot redundancy based continuously available fire alarm panel & false alarm filtering type detector at 400kv r.s. division, lonikand-ii- 3rd call
Tender For construction of permanent building for echs polyclinic (type - d) at nagapattinam. sh: building portion including water supply, sanitary installation, civil external service connection , sewer lines , oht without independent staging , water proofing work, ug sump, frp biodigester, gi sheds for diesel generator set & ambulance parking, development works including borewell, compound wall, levelling, paver block & other miscellaneous works including internal electrical installations, lightning conductors, external service (mv panel & ug cabling) , illuminated signages, ro plant, water coolers, solar pv system , diesel generator set, split type ac, fire alarm system, and external lighting
Tender For supply of installation of network fire alarm panel - supply installation of network fire alarm panel model fc922 siemens , supply installation of monitor module for wld temperature and fire panels etc integraation at data centre panel model xtri m siemens , supply installation of relay module for hooters installed at security gate siemens , supply installation of hooter cum strobe siemens , ms enclosures for modules fixing , supply installation of 24v power supply modules for hooters , supply and laying of cabling for ibms panels like wld temperature and egdms fire alarm panel etc to fire alarm panel at new data centre , supply and laying of 6 core single model ofc cable legrand or d link , supply and installation of media converters patch cords and required splicing setuup for ofc cable , hard soil excavation and closing for cable road crossing upto 15 mtr length , commissioning and testing charges for above setup
Tender For bid to ras round the clock running operation and routine maintenance , custom bid for services - annual maintenance contract for fire pumps of capacity installed , custom bid for services - providing laying testing and commissioning of 150 mm dia gi pipe , custom bid for services - refilling and hpt of co2 type fire extinguisher 4 point 5 kg , custom bid for services - refilling and hpt of abc type fire extinguisher 6 kg , custom bid for services - supply and installation of discharge horn for co2 fire extinguisher 4 point 5 kg , custom bid for services - supply and installation of discharge tube for co2 fire extinguisher 4 point 5 kg , custom bid for services - supply and installation of discharge tube for abc fire extinguisher 6 kg , custom bid for services - fire audit and issuing of form b of all buildings at aiims nagpur , custom bid for services - supply and installation of wafer type non-return valve of size 100mm dia , custom bid for services - supply and installation of wafer type non-return valve of size 150mm dia , custom bid for services - supply and installation of 63 mm dia ss gun metal hydrant valve , custom bid for services - supply and installation of fire brigade connection 2 way , custom bid for services - supply and installation of abc type fire extinguisher 6 kg capacity , custom bid for services - supply and installation of co2 type fire extinguisher 4 point 5 kg capacity , custom bid for services - annual maintenance contract for fire alarm and public address system , custom bid for services - sitc of fire alarm conventional panel , custom bid for services - supply and installation of amplifier of pa system , custom bid for services - supply and installation of loop card for fire alarm panel , custom bid for services - sitc of fire alarm panel , custom bid for services - annual maintenance contract of novec 1230 gas suppression system , custom bid for services - annual maintenance contract of co2 flooding system , custom bid for services - supply of novec 1230 cylinder 2 point 5 lb , custom bid for services - supply of novec 1230 cylinder 10 lb , custom bid for services - sitc of gas release panel for co2 flooding system , custom bid for services - refilling of co2 cylinder 45 kg , custom bid for services - refilling of co2 cylinder 22 point 5 kg , custom bid for services - refilling and hpt of nitrogen cylinders 3 kg , custom bid for services - refilling and hpt of novec 1230 cylinder 2 point 5 lb , custom bid for services - refilling and hpt of novec 1230 cylinder 10 lb , custom bid for services - annual maintenance contract of nifps
Tender For tender for repair/replacement of damaged/defective equipments in control room/yard at various sub-stations under electrical system division hpsebl una - replacement of defective space heaters (230v ac, 40 watt) along with thermostate (1 for 2 heaters) (range 30 degree c - 85 degree c) at 66kv sub-station, gwalthai, replacement of industrial standard warm white 250 watt led light (make ;- crompton/ havells/ bajaj/ orient), high mast/ flood light, ip 65/ ip 66 compliant (one year onsite warranty) including fabrication of clamps, 2.5 sq mm cable wiring etc. as per the satisfaction of engineer in-charge at 132kv sub-station, una, replacement of industrial standard warm white 250 watt led light (make ;- crompton/ havells/ bajaj/ orient), high mast/ flood light, ip 65/ ip 66 compliant (one year onsite warranty) including fabrication of clamps, 2.5 sq mm cable wiring etc. as per the satisfaction of engineer in-charge at 132kv sub-station, amb, repalcement of control room defective led white tube light (cool whitle) 20 watt, supply voltage 220v ac (make: philips/ bajal/ crompton/panasonic) at 132kv sub-station, hpsebl amb, replacement of defective ceiling fan 1400 mm high speed 390 rpm, rust proof body supply voltage 220 v ac (make: philips/ bajal/ crompton/panasonic) at 132kv sub-station, hpsebl amb, replacement of defective 12-inch portable anti-rust exhaust fan, quiet & adjustable for any space 300 mm exhaust fan(make: philips/ bajal/ crompton/panasonic) for battery charging room at 132kv sub-station amb, replacement of defective 12 window microprocessor based alarm announciator, voltage-220 v dc (make minilec model 312b mp0 big window) at 33kv feeder panel at 132kv sub-station, hpsebl amb., replacement of defective indication lamp for c&r panel (red-15, green-15, white-5 yellow-5, blue-5) supply voltage-30v-240 v ac/dc at 132kv sub-station amb, repalcement of defective jvs tripping relay type jrv 171 voltage 220 v dc as per sample at 132kv sub-station amb, repalcement of defective jvs type tcsr relay jrv 111 voltage 220 v dc as per sample at 132kv sub-station amb, quantities are mentioned above are tentative and actual quantity shall be worked out .payment shall be made as per approved bill of material/actual quantities measured at site.
Tender For design, engineering, supply, installation, testing and commissioning of an alert, inform and direct system at six (6) sites - control & monitoring :- the control room shall be set up in the already constructed/available room at the pandoh dam area. this system should include a minimum 43-inch (hd) screen with an adjustable stand, capable of monitoring the operation of the siren station. it should display all feedback, including the status of being on or off, battery health, any faults etc. in the installed equipment. additionally, this system must have the capability to communicate directly with the control room to provide alerts and information in real time., for supply ,testing, designing, erection and commissioning of local station for alert, information and direct system comprising of the following hardware/software: panel/housing with power supply module. the controller, linked with all the control units through a communication and integration unit, displays the system via screens. the sirens should also be remote controlled. the control of the sirens should be according to the commands received from the remote central control station through a two-way gsm/gprs/3g/4g/lte and provision of vsat. security feature including intrusion alarm auxiliary/status control board for contact closure activation and status. the siren system should withstand outdoor environment condition & the siren assembly should be rust proof to withstand harsh and saline environmental condition. single point clicks activation & polling. status monitoring. complete configuration & reprogramming for control site. minimum 15,000 message alert notification through gsm/3g/4g/5g/lte/vsat to bbmb officials/ administrators and local residents according to requirement. programmable hot keys. communication over tcp/ip secure access with password. ethernet cable length :- the bidder shall be responsible for the supply and erection of all cabling required for the complete system, ensuring that the cables are of reputable make only and conform to the prescribed standards as per site requirements. rtu & software :- the r.t.u. and software as per the manufacturer`s design / program, the software should be suitable for controls up to 100+ sirens, the system can be expanded to accommodate changing needs. the software should be app and web based. communication between control centre and sirens. :- gsm/3g/4g/5g/lte network/vsat. pre-recorded voice messages :- live and pre-recorded voice messages in minimum 3 local languages i.e. (hindi, punjabi and english) strobe light :- high intensity led strobe light, color red, amber, green, 60-120 flashes per minute (adjustable), led life > 50000 hrs., pole/top mountable with 360 visibility preferably ip 66. alert tones & voice:- minimum 5 standard alert tones. support transmission of stored voice in siren/voice controller through wave file in memory card, remote activation. remote activation of alert tones and pre-recorded voices the voice messages will be customized, optimized for good quality for the intended location, language preferably in punjabi, hindi & english. warranty period:- 3 years., input power source :- the quantity of solar photovoltaic panels and batteries shall be adequate to meet the systems operational requirements. only reputed manufacturers such as tata solar, vikram, waaree, reil, or equivalent brands shall be supplied. the solar panel input source shall be integrated with the required number of batteries to run the installed system continuously for a minimum duration of three (3) days under idle running conditions. this includes six (6) operational cycles per day, with each cycle lasting a minimum of twenty (20) minutes. a secondary provision for electrical input supply shall be provided to enable system operation in the event of solar panel failure or insufficiency beyond the designed power supply capacity., siren type :- bi-directional electronic siren pre-programmed audio amp