Web Analytics Made Easy - StatCounter

Lightning Protection Repair Tenders

Get complete information related to latest Lightning Protection Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lightning Protection Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lightning Protection Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :43180886 Due date: 17 Dec, 202517 Dec, 2025 NA
Tender For electrical wiring work at faculty of art (dean/meeting room).

Central Government/Public Sector

CTN :43182938 Due date: 26 Dec, 202526 Dec, 2025 4.68 Lacs
Tender For replacement of ups db along with associated wiring at technical block (electrical work)

Co-operative

CTN :43205408 Due date: 29 Dec, 202529 Dec, 2025 NA
Tender For removal of the existing false ceiling and installation of a new gypsum fa lse ceilin g, along with complete electrical wiring & other allied work at the bank premises of the eastern railway employees' co- operative bank ltd., mughalsari

State Government

CTN :43207261 Due date: 06 Jan, 202606 Jan, 2026 4.50 Lacs
Tender For miscellaneous electrical wiring & light fittings maintenance & renovation work on as and when required basis at c.s.power company premises danganiya raipur.

State Government

CTN :43208747 Due date: 19 Dec, 202519 Dec, 2025 2.95 Lacs
Tender For electrical re-wiring work along with replacement of battery to restore the power supply at ground floor, cyber library. central library bhu.

State Government

CTN :43208920 Due date: 31 Dec, 202531 Dec, 2025 NA
Tender For general- providing ups wiring to the dtp department in meppadi press wayanad district.election work-ups wiring-general electrical work

CTN :43181819 Due date: 19 Dec, 202519 Dec, 2025 14.38 Lacs
Tender For repair & replacement of main electric wiring of abc and 5 rooms of dc divisions (from main switch room to distribution boxes) along with distribution boxes at icar-ndri, karnal.subwork/packages:electrical work

CTN :43169936 Due date: 02 Jan, 202602 Jan, 2026 NA
Tender For supply of refurbishment of clothing store office at ins angre : :--entrance door panelling work , entrance wooden door , sofa seating , providing and fitting curtain with ss rod fitting outside area , wooden partition , working desk , proposed rack inside workstation area , storage providing and fixing wooden storage , officers table providing , wooden door providing , wooden door to the storage area providing , officers table providing and fixing directors table , working table providing and fixing working table for packing clothes , proposed rack inside storage area , wooden door providing and fixing wooden door shutter , false ceiling work , wall painting , ceiling painting work , electrical works 1 point 5 sqmm point wiring , 2 point 5 sqmm point wiring , cob lights , tube light , fan , switchboard , plug points 5 amp , plug point 15 amp , 2ton ac , ac point

CTN :43144582 Due date: 22 Dec, 202522 Dec, 2025 30.00 Lacs
Tender For providing of customized amc/cmc for pre-owned products - electrical wiring and rewiring other repairing work as per cpwd dsr electrical and mechanical 2022-23 cpwd prevalent rate; na; annual maintenance contract (amc); monthly; yes

CTN :43140429 Due date: 25 Dec, 202525 Dec, 2025 34.90 Lacs
Tender For - arc of electrical material. - electrical work :, providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket/pole. fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with uv stabilized pc (uv stablization report submitted for uv cover ) /toughened glass cover and secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm/ wt and potted driver & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driver efficiency >85% ,thd(i) 10% humidity 10% to 90% rh working temp -5c to 45c . driver current 750ma. the luminaire shall be bis certified and trade mark certified. life expectancy equal or more than 50000 burning hrs with minimum 70% lumen maintened , cri >70 and cct 5700k +355k. surge protection shall be min 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark/name engraved/embossing on die cast housing to allow traceability/authenticity. fixture shall be as per is 10322 complianced.oem must have its own in house nabl lab setup for all testing facilities for led fixtures. (lm79/lm80) certificate/ report with liable warranty of product/accessories from oem shall be submitted. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr . led street light fixture with minimum lumen output 5600 lm, supplying and drawing of xlpe insulated lt aerial bunched aluminium conductor cable confirming to is 14255/1995 and is 398 (pt-4)/ 1994 and as per discom specs. on existing cross arms through i hook with all necessary t&p required including binding and twisting etc. complete in all respect as required. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr . 1 x 25 sq. mm. + 1x25 sq. mm. (insulated), supply and fixing of 11 kv pin insulator confirming to is:731:1971 with latest ammendment on existing bracket including all accessories like ms forged hot dipped gi pin confirming to is 2486(part-i)/1993 & is:2486 (part-ii)/1989 with latest amendment, and as per latest discom specs. etc. as required. all as per pre approved by engineer in-charge.for additional technical parameters of product / work refer annexure a attached with this bsr, sitc of ip-42 and general construction confirming to is:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)thickness of crca sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel. the panel having pe foam/ neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only. all joints / interconnections of copper bus bar shall be dully tinned . c
 Loading, Please wait...

Connect us via What's Up