Tender For supply of 0.33 in day night colour ip fixed camera , day night colour ip ptz dome camera , 1 mp or better bullet camera , 3 to 5 meter pole for mounting of cctv , 08 port industrial grade layer 2 network , wall mounted cabinet , ip telephone instrument , power cable 3 core x 2.5 sqm armoured , armored cat 6 utp networking cable , foundation laying and erection , commissioning and modification , testing commissioning and modification , testing and commissioning of complete cc
Tender For prov, fixing, jointing, testing and commissioning of 50 sqmm 3.50 core aluminum conductor cable complete in all respects. /50 sqmm 3.50 core / at w/w nangal mundi
Tender For prov, fixing, jointing, testing and commissioning of 50 sqmm 3.50 core aluminum conductor cable complete in all respects. /50 sqmm 3.50 core / at w/w nangal mundi
Tender For supply and testing of 4 core 120sq. mm lt power cable aluminium balance stranded conduct or, xlpe insulated, cores laid up, pvc tape innersheathed armoured with galvanised wire, extruted pvc typ e st2 outersheathed, 650/1100v grade as per is:7098 (part1):1988 or latest. make : havells, finolex, kei, p olycab [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ]
Tender For corrigendum : supplying,laying,termination,testing and commissioning of 132kv single core,630mm2 aluminium conductor xlpe insulated,corrugated aluminium sheathed ug cable and for 110kv gi at 110 kv substation malappuram
Tender For 1)supply of two nos. of out door type 750kva, 11kv/400v, onan auxiliary transformer along with oil as per site requirement 2)supply of lt copper power cable 400v, 1.1kv grade pvc armored 3.5 core 2rx 400 sqmmm along with lv cable termination accessories,lugs etc 3)dismantling of existing 2 nos. of 750kva auxiliary transformers and old oil cooled cables at ltac panel and auxiliary transformer end and its accessories 4) laying of lt copper power cables and termination of cables along with supply of all accessories for laying of cables 5)erection, cabling, testing and commissioning of 2 nos. of 750kva,11kv/400v auxiliary transformers 6)buy back of released two nos. of 750kva auxiliary transformers along with oil
Tender For supply, erection, testing & commissioning of 24-core armoured underground optical fibre for main sldc, breda bhawan, patna & back up sldc, gaya along with associated communication equipment for uldc phase-iii scada /ems upgradation project
Tender For supply of disconnecting and taking out defective under ground lt cable from trenches , supply laying testing and connecting xlpe sheathedpvc insulated screened pvc beddedgalvanised steel strip , all as per boq item no 200 here in before but of size 40 core 16 sqmm complete all as specified , all as per boq item no 200 here in before but of size 35 core 25 sqmm complete all as specified , all as per boq item no 200 here in before but of size 35 core 50 sqmm complete all as specified , all as per boq item no 200 here in before but of size 35 core 70 sqmm complete all as specified , all as per boq item no 200 here in before but of size 35 core 95 sqmm complete all as specified , laying only and connecting xlpe sheathedpvc insulated screened steel strip of wire armoured electric power cable , all as per boq item no 800 hereinbefore but of size 40 core 16 sqmm complete all as specified , all as per boq item no 800 hereinbefore but of size 35 core 25 sqmm complete all as specified , all as per boq item no 800 hereinbefore but of size 35 core 50 sqmm complete all as specified , all as per boq item no 800 hereinbefore but of size 35 core 70 sqmm complete all as specified , excavating in trenches nexc 15 m wide and nexc 15 m depth for foundation etc or for shafts wells cesspits manhole pier hole , returning filling in including spreading levelling watering and well ramming in layers not exc 250mm in soft loose soil complete all as specified and as directed , removing excavated materials soils not exc 5000 mtr and depositing where directed at a level not exc 150 mtr above the starting point in soil complete all as specified and as directed , mandl sand cushioning dry in trenches for protection of ug cables below above and around the ug cable laid in trenches , mandl for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of ug cable , supplying and fixing galvanised mild steel pipe tubing light grade complete with all fittings of 80 mm bore dia , supplying and fixing galvanised mild steel pipe tubing light grade complete with all fittings of 50 mm bore dia , supplying and fixing galvanised mild steel pipe tubing light grade complete with all fittings of 100 mm bore dia , m and l for boring of horizontal hole under road pavement hardstanding suitable for passing through up to 80 mm bore , mandl for straight through joint heat shrinkable complete suitable for lt 1100 volt aluminium conductor cable , mandl for straight through joint heat shrinkable complete suitable for lt 1100 volt aluminium conductor cable of size35 4 x 2550 sqmm , mandl for straight through joint heat shrinkable complete suitable for lt 1100 volt aluminium conductor cable of size35 x 70150 sqmm , supplying and fixing high density polyethylene pipes hdpe of pressure rating 6 kgf cm2 complete with all fittings of 25 mm bore dia , supplying and fixing high density polyethylene pipes hdpe of pressure rating 6 kgf cm2 complete with all fittings of 40 mm bore dia , supplying and fixing high density polyethylene pipes hdpe of pressure rating 6 kgf cm2 complete with all fittings of 50 mm bore dia , supplying and fixing high density polyethylene pipes hdpe of pressure rating 6 kgf cm2 complete with all fittings of 100 mm bore dia , material and labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm mm buried directly in ground , dismantling existing lt panels of any type any size carefully for reuse including necessary excavation demolition of concrete , labour only for disconnecting isolating and taking out burned unserviceable lugs switchgear metering devices wiring bus bar etc , supply only the followings to be incorporated against item no 3000 and 3100 only 06 sqmm to 16 sqmm , 25 sqmm to 50 sqmm , 70 sqmm to 95 sqmm , 120 sqmm to 240 sqmm , epoxy type insulator upto 1100volt for lt panel bus bar including nut bolts etc complete all as specified and as directed , single core stranded copper c