Tender For supply of medical equipment--chemical reagents (chemical reaction) suitable for the machines available in the hospital lab material x-ray film and left kit,equipment and material required for the hospital for dressing material etc.ayurvedic scriptures and patent medicines,cleaning material,chemical reagents used in biometric analysis cell counter,chemical reagents used in hormone analyzer,digital x-ray film (8 by 10,
Tender For corrigendum : purchase of biochemistry lab equipments - fully automatic biochemistry analyzerthroughput: 200 photometric tests/hour & 400 tests/hour with ise (optional)reagent positions: 50 cooled reagent positionssample type: whole blood, serum, plasma, urine, csf otherreading volume: 180 lsample volume: 2-70 l (adjustable in 0.1 l)reagent volume: 10-300 l (adjustable in 1 l)light source: halogen lampon board laundry: 6 stage cleaning, 2 stage drying with cuvette validation stepcalibration type: linear, non-linear, multipointprogrammable parameters: default system pack parameters + upto 10 user defined parametersdimensions and weight: ergonomic design and light weight., fully automatic hematology analyzerthroughput-up to 80 samples per hourdimensions and weight ergonomic design and light weighttest mode-cbc, cbc+diffdata storage capacity-up to 100 000 resultscommunication-lan port supports hl7 protocolpower requirement-a.c. 100-240 v, less than or equal to 300 va, 50/60 hzoperating temperature-15 to 30 degree celsiusoperating humidity-30-85%air pressure70-106 kpa, fully automatic immunoassay analyser random assay (hormone analyser)instrument name: immunoassay analyserusage/application-clinicalplate format-random assaydetection method-luminescenceparameters-blood alcohol contentautomation-fully automaticuser input-touchassays-diabetes, thyroid, cardiac, vit d, fully automatic electrolyte analyser-analysis time: 60 second per sample parameters- na , k , cl or ca2+no. of parameters 3 simultaneously90 luser inputs 5 colored touch screen displayelectrode type- sturdy electrode (facility to refill the solution)connectivity 2 usb port, rs232, lisdata storage- 10,000 patient results & 10,000 qc results for 3 levelssample identification- alphanumeric sample idqc management- tri-level quality control, l j plots of last 30 dayscalibration- 2 point calibration on every 4 hours1 point with every samplepower - 100 240 v, 50/60 hz (self adjusting)printer - inbuilt thermal printerroom temperature -15 30 c / 60 90 fhumidity- 85%dimensions and weight - ergonomic design and light weight, centrifuge machine along with 500 prp test tubes (double spin)parameter- neya-16 max speed (rpm)- 15000max rcf (g)- 21000max capacity (ml)- 4 x 175acceleration profiles- 10deceleration profiles- 10display-- multi-color lcdno of programmes- 10 (protected)timer- 30 sec to 99 min & continuous modeergonomic design and light weightsupply - 220v, 50 hz, 1 phasecan be used for extracting prp, autoclavekey features- high-pressure vessel: a high-pressure vessel designed to withstand high temperatures and pressures- temperature control: precise temperature control to ensure effective sterilization- timer and controls: easy-to-use timer and controls for convenient operation- safety features: multiple safety features, such as automatic shut-off and overheat protection, to prevent accidents and ensure safe operationconstruction and materials- stainless steel: a durable stainless steel construction to withstand high temperatures and pressures- insulation: high-quality insulation to ensure efficient heat retention and energy savings- door and seals: a secure door and seal system to prevent steam escape and ensure effective sterilizationperformance specifications- temperature range: 121 c to 134 c.- pressure range: upto 30 psi- cycle time: 15-60 minutes- sterilization capacity in liters or cubic feetsafety standards- compliance with regulations: compliance with relevant regulations, such as asme, fda, and iso standards- automatic safety devices: automatic safety devices, such as overheat protection and low-water cut off, to prevent accidents and ensure safe operation- interlocks: interlocks to prevent door opening during operation and ensure user safetyadditional features- data logging: optional data logging capabilities to track temperature, pressure, and cycle data- printed records: optional printed records of cycle data for documentation and quality control- val
Tender For purchase of consumables for multi disciplinary reseach unit,gmct - dna extraction kit (blood) 50 sampleable to isolate from whole blood (fresh/frozen, edta-treated); spin-column based, final dna yield: 5 10 g per 200 l blood: purity: a260/280 = 1.7 1.9, dnase/rnase-free: certified, certifications: iso 13485, ce-ivd, dna extraction kit (tissue) 50 sampleable to isolate from fresh tissue; spin-column based, final dna purity: a260/280 = 1.7 1.9, dnase/rnase-free: certified, certifications: iso 13485, ce-ivd, rna isolation kit blood 50 sample should not be with phenol chloroform method, should be spin-column based, certified, certifications: iso 13485, ce-ivd needed50 sample , rna isolation kit tissue50 sampleable to isolate from fresh tissue; should not be with phenol chloroform method, should be spin-column based; certified, certifications: iso 13485, ce-ivd, rsa 1 restriction enzyme-1000 u (rhodopsuedomonas sphaeroides) recognition site: 5...gt^ac...3 (blunt-end cutter); quantity: 1000 units grade: molecular biology grade, rnase/dnase-free, supplied with suitable 10x buffer, must have: certificate of analysis, product datasheet, batch label, human ins (insulin) elisa kit-96 t- assay type: sandwich elisa, sensitivity: high sensitivity ( 5 iu/ml preferred), sample type: serum, plasma, includes: complete kit with standards, detection reagents, buffers, and plate, must include: certificate of analysis, datasheet, lot number on packaging, pcr master mix25ul x 200 reaction ready-to-use solution for standard pcr, grade: molecular biology grade rnase- and dnase-free, human angiotensin converting enzyme elisa kit,96t (serum) 96-well plate (sandwich elisa), sample type: serum, plasma, must include: certificate of analysis, datasheet, lot number on packaging, human osteoprotegerin (opg) kit-96t -96-well plate (sandwich elisa), sample types: serum, plasma, purity: rnase- and dnase-free reagents, endotoxin-free, application: quantitative detection of human opg in biological samples, grade: molecular biology grade suitable for sensitive research applications., interleukin -6 elisa kit- 96 t- sandwich elisa for quantitative detection of il-6 in serum, plasma, and other biological fluids, grade: molecular biology grade. must include: certificate of analysis, datasheet, lot number on packaging, hs-crp elisa kit-96t-- a sandwich elisa designed for quantitative detection of human hs-crp in serum, plasma, and other biological fluids. grade: molecular biology grade, total t3 thyroid elisa kit -96t with zebrafish reactivity --a sandwich elisa designed for quantitative detection of total t3 thyroid hormone in biological fluids of zebra fish. grade: molecular biology grade, total t4 thyroid elisa kit -96t with zebrafish reactivity --a sandwich elisa designed for quantitative detection of total t4 thyroid hormone in biological fluids of zebra fish. grade: molecular biology grade, anti tpo thyroid elisa kit -96t with zebrafish reactivity- a sandwich elisa designed for quantitative detection of anti tpothyroid antibody in biological fluids of zebra fish. grade: molecular biology grade, anti tg thyroid elisa kit -96t with zebrafish reactivity- a sandwich elisa designed for quantitative detection of anti tgthyroid antibody in biological fluids of zebra fish. grade: molecular biology grade, pcr tube, 0.2ml, transparent 500/pkt individual tubes , flat cap, made from virgin polypropylene (pp), pcr 8 well strips with cap, 0.2ml, transparent. 8-strip tubes: eight tubes connected in a strip, with a single strip cap. flat caps: made from virgin polypropylene (pp)125 x 8-strip tubes/pkt, transgenic zebrafish tg (tg:mcherry) thyroid fluorescent the transgenic zebrafish should express mcherry (a red fluorescent protein) specifically in the thyroid gland under the control of the tg promoter, with a heterozygous genotype preferred. required are 100 embryos (1 5 dpf), juveniles, or 20 adults (equal male and female), certified specific pathogen-free, on an ab or wild-ty
Tender For supply of srphc047500-human parathyroid hormone rdna origin 750 mcg cartridge (teripara tide) unit:cart [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: ma x 8 lacs ]