Get complete information related to latest Lithium Coin Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lithium Coin Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lithium Coin Tenders.
Tender For supply and commissioning of 3kva on-line ups with 120 minutes battery back-up 72v system, mosfet-pwm with in-built isolation technology, input power ? single phase 160-260v ac 50hz, output voltage single phase 230v ac +/-1%, sine wave 50hz, minimum vah ? 9600, protection - ip21, smf-vrla battery as per is: jisc:8702 (part i, ii, iii) with rack, over voltage/ under voltage/ overload and short circuitprotection at ups output terminals, max thd - 3%, digital metering in ups for data, efficiency >90%, 20% overload limit for 10 minutes, max overshoot and under shoot of output rated voltage - 4, voltage regulation from no load to full load - 3%, minimum 1,2 mm thick ms sheet enclosure with duly painted. with typetest report, minimum warranty of machine 2 years, make: microtek/apc/luminous/nps/techser. [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : supply of repair and preventive maintenance of dg set ranchi oa - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva //bid details 2 / 35
Tender For corrigendum : providing of repair maintenance of dg set hazaribag - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva
Tender For corrigendum : providing of repair and maintenance of dg set under daltonganj - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva
Tender For corrigendum : supply of lithiumcoin cell battery suitable for control module motherboards of m/s. medha spm, modelno. br 2335, 3.2 v. make: panasonic or sony or equivalent. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For corrigendum : tender for supply of fids and 05 years camc at srinagar airport : - supply of 3 x 2 mtrs. or higher true colour led display board with stainless steel floor ceiling wall mounting arrangement. , supply of 65 inch led display with floorceiling wall mounts as per the specifications , supply of 55 inch led display with floor ceiling wall mounts as per the specifications , supply of 43 inch led display with floor ceiling wall mounts as per the specifications , supply of fids servers to work as main and standby set of two servers with accessories as per the tender specifications. , supply of data entry terminal client desktop pc with all accessories as per the tender specifications. , supply of ntp server with accessories as per tender specifications. , supply of licensed operating system server level with support for all servers , supply of operating system at client level pc work station etc. with support for all clients , supply of licensed antivirus server level with support for all servers , supply of licensed antivirus client level with support for all servers , supply of layer 3 network switch as per technical specifications and accessories with rack , patch panel , liu and other accessories , supply of layer 2 network switch as per technical specifications and accessories with rack , patch panel , liu and other accessories , supply of 12v 84ah battery for the 2x 20kva ups of make numeric hp max. the cost of old batteries connected to ups shall be considerd while qouting and shall be handed over to contractor as buy back. , supply of fids package software as per requirement of the tender , supply of 8 port kvm switch. , supply and laying of 25 mm dia , 16 swg isi marked pvc conduit with accessories as required , supply and laying of 3 core 6 sq mm multi strand copper conductor pvc insulated pvc sheathed armoured power cable on wall surface tray with accessories as required , supply and laying of 3 core 1.5 sq mm multistrand copper conductor pvc insulated pvc sheathed unarmoured power cable in existing conduit tray with accessories as required , supply and laying of 6 core smf ofc unarmoured cable on wall surface tray with accessories as required , supply and laying of utp cat 6 cable in existing conduit tray with accessories including termination with wall surface mount box as required , supply of power distribution panel complete as per specifications for flds system. , excavation soft digging back filling as per site requirement , supply of rj45 io face plate gang boxback box with standard length of patch cable for fid system as per site requirement and specifications , training and documentation as per tender , charges for installation testing and commissioning of the complete system including integration of existing 24 nos , cids with new fids system.