Get complete information related to latest Load Tap Changer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Load Tap Changer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Load Tap Changer Tenders.
Tender For research based pilot project [dynamic feeder voltage manager (dfvm)] for turnkey based work of design, development, supply, installation, testing & commissioning of 3-ph, 50 hz, 4000 kva, 12/12kv outdoor onan auto/power transformers equipped with on-loadtapchanger (oltc) with necessary infrastructure and protections, master controller and around 100 modems, control circuits with comprehensive maintenance contract for 05 (five years) after handing over the project
Tender For supply & testing of 500 kva, 11kv/750v, 3-phase, 50 hz. outdoor type power transformer conforming to 15 2026 (part 1): 2011 (reaffirmed 2021), plinth mounted, copper wound, mineral oil immersed with freely breathing system (also called conservator system) as per clause 8.2 (a) of is 2026 (part 1), primary winding in delta and secondary winding in star (vector symbol-dyn11), onan cooled transformer, minimum short circuit impedance of 5% as per is 2026 (part 5), with all fittings specified in annexure a to this description, terminal arrangement: the transformers shall be fitted on high voltage and low voltage sides with outdoor type bushings of appropriate voltage and current ratings. the high voltage bushings (3 nos.) shall confirm to is/iec 60137. the low voltage bushings (4) nos.) shall conform to 15.7421. suitable cable-end box is to be provided as follows: a) for outdoor type: l.t. side tapchanger: on-loadtapchangerfor variation of hv voltage from -+5% to -5% in steps of 1.25% make- andrew yule/aeg/crompton greaves/kirloskar electric co./abb/siemens/schneider or similar. [ warranty period: 30 months after the date of delivery ] ]
Tender For distribution transformer of rating 250 kva, 11kv/415v-240v, 3-phase, 50hz, outdoor type, plinth mounted, the type of tapchanger: off-loadtapchanger for variation of hv voltage from +5% to -10% in steps of 2.5%, energy efficiency level 3 or better, oil immersed, non-sealed type (transformer tank body and cover are bolted), copper wound, primary winding in delta and secondary winding in star (vector symbol- dyn11), onan cooled transformer, conforming to is 1180 (part 1):2014 with amendment nos. 1,2,3,4 or latest, and supplied with all standard fittings mentioned in clause 20.1 of is 1180 (part 1) latest withcondition that drain-cum-sampling valve will be applicable for all capacity of transformers. oil temperature indicator & winding temperature indicators will be provided as per clause 20.2 f) of is 1180 (part 1). terminal arrangement: the transformers shall be fitted on high voltage and low voltage sides with outdoor type bushings of appropriate voltage and current ratings. the high voltage bushings (3 nos.) shall conform to is/iec 60137. the low voltage bushings (4 nos.) shall conform to is 7421. suitable cable-end box along with cable entry hole glands is to be provided at l.t. side. following has to be submitted by supplier along with supply of material: (i) type test report of transformer having same rating, make (& model if any) and design from nabl accredited lab as per is: 1180 (part 1) latest. (ii) routine test certificates as per is: 1180 (part 1) latest. (iii) special test certificates as per clause 21.4 sl. no. (a), (c), (d) & (e) of is: 1180 (part 1) latest. detailed specification attached as annexure a. [ warranty period: 30 months after the date of delivery ]]
Tender For technical bid for supply of hvac operational spares , bearing (6206) size: od, 60 mm x id 50 mm ball bearing desig: 6001-z, ball bearing desig: 6307/2z c3 universal hvac/r controller, armoured 4 core x 6 sqmm xlpe copper cable. 1 sqmm frls multi stranded copper cable (single wire), 10 sqmm frls multi stranded copper cable (single wire) 4 sqmm frls multi stranded copper cable (single wire), fibre glass insulated copper wire for heater size: 6 sqmm, alkaline battery volt: 9vf sealed maintenance free (smf) lean-acid battery 7ah 12v, brush width: 3 inch for painting work. loctite 495 adhesive, kiwi drain cleaner heavy duty industrial safety gloves - cut-resistant (mechanical work), spray foam insulation (pfu) can qty: 750 ml wd 40 multipurpose spray size: 500 ml, green paint (bus green synthetic enamel black paint (synthetic enamel), ms flat bar size: 40 x 5 mm ms l- angle size: 25 x 25 x 5 mm, ms l- angle size: 40 x 40 x 5 mm metal primer (red oxide), black color spary paint 400 ml thread repair helicoil insert ss-m18 x 2.5mm x 1.5d, thread repair helicoil insert ss-m20 x 2.5mm x 1.5d thread repair helicoil, insert ss-m24 x 3mm x 1.5d thinner for oil-based paints, wire type buffing whee bench grinder wheel -heavy grade, dial test indicator (dti) gauge with flexible stem magnetic base stand, digital clamp meter capacity: 600a ac trms heavy duty exhaust fan, size: 9 inch backward curved fan with motor size: 355, mm dia ventilation fan for electrical panel sweep, dia: 12 cm induction motor fan, blade shaft size: 20 mm & blade dia: 130 mm, induction motor fan blade shaft size: 25 mm, & blade dia: 110 mm gi 6 mm x 25 mm bolt & nut with washer, anchor bolt with nut & washer size: 10 mm anchor bolt with nut &, washer size: 8 mm anchor fastner size: 10, mm for threaded rod gi self tapping screw, size: 3/4 inch (20 mm) head type: truss, pop screw size: 1 inch (25 mm) head type: flat (csk). ss self tapping screw size: 2 inch (50 mm), head type: hex din rail size: 35 x 7.5 mm, add on auxiliary contact block (1 no +1 nc) casing and capping size: 20mm (3/4 inch), casing and capping size: 50mm (2 inch) copper strip for electrical motor size: 25 x 3 mm, current transformer (for mfm/ammeter), ratio: 10/5a current transformer (for mfm/ammeter), ratio: 15/5a, current transformer (for mfm/ammeter), ratio: 20/5a current transformer (for mfm/ammeter), ratio: 30/5a, current transformer (for mfm/ammeter), ratio: 5/5a emergency stop switch, metal enclosure electrical junction box, size: 200mmx200mmx150mm, metal enclosure electrical junction box size:, 300mmx300mmx200mm three pole neutral (4p), 32 amps miniature circuit breaker (mcb) 4-way mcb metal enclosure, 2- module surface mounted pvc box. thermal overload relay, range: 14-23 amps electronic fan regulator, single module porcelain heater insulators or terminal. blocks, led indicator color: amber pin type lug size: 1.5 sqmm, pin type lug size: 2.5 sqmm pin type lug size: 4 sqmm, pin type lug size: 6 sqmm spade type lug size: 1.5 sqmm, spade type lug size: 2.5 sqmm metal flexible conduit size:19, motor protection circuit breaker (mpcb) range: 6.3-10 amps (rotary) motor protection circuit breaker (mpcb) inst trip rating: 2.5 amps (rotary), motor protection circuit breaker (mpcb) inst trip rating: 25 amps (rotary) motor protection circuit breaker (mpcb) inst trip rating: 50 amps (rotary), ms conduit size: 25 mm motor terminal block range: 10 hp/7.5 kw, motor terminal block range: 40 hp/30 kw thermal overload relay(olr) range: 20-33 amps, thermal overload relay(olr) range: 42-69 amps plug top 3 pin capacity: 5 amps, 4 pole power contactor capacity: mnx 12 4 pole power contactor capacity: mnx 18, 4 pole power contactor capacity: mnx 9 push button (illuminated) color: green, push button (illuminated) color: red plugable interface relay (4 c/o, 230 vac) with base, plugable interface relay (4 c/o, 24 vac) with base analog timer controller for split ac's, terminal block range: 0.2-2.5 sqmm,
Tender For corrigendum : providing services overhauling and testing of on-loadtapchanger (oltc) make ctr and high voltage circuit breaker on-site at hbl plant sugauli
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - repair/rewinding of 07 nos. cooling fan motors of interlinking transformer installed at 220 kv switchyard bhakra left bank power house along with replacement of its old parts such as bearings, glands, o-rings, etc.
Tender For corrigendum : supply of service 11 kv ht panel as per sepcifications , sf new mineral oil for panel etc as per sepcifications , calibration relay etc as per sepcifications , replacement digital ammeter for ht panel , replacement digital voltmeter for ht panel , replacment ryb ind lamp led type in ht panel , sf 2a hrc fuselink in ht panel , servicing 1500kva dry type transformer as per sepcifications , servicing 2 runs 2500a tpn bustrunking as per sepcifications , service mv lt panel with 2500a 4p acb 3 nos as per specifications , service mvlt panel with mccb incoming as per specifications , checking and repair of em intelocking , dismentaling 3.5 sq mm 240 or 300 sq mm al cable as required , pf adaptor box aprx 1.5 ft x 1.5 ft x 1.5ft of 16swg ms sheet as reqd , pvdg panel module door key as reqd , pvd and fixing operating handle for 250a 4p changeover as reqd , replacement 160a hrc fuse with base in extg cap panel , replacement 3p 50kvar cap duty contactor in extg cap panel , replacement 25sq mm cu lead wire 1ft length in extg cap panel , checking etxg 2no 25kvar cap bank and fault repair reinstallation , dismentaling uv protection connections as reqd , replacement digital ammeter for lt panel , replacement digital voltmeter for lt panel , replacment selector switch in lt panel , replacment ryb ind lamp led type in lt panel , sf 2a hrc fuselink in lt panel , sf 32a hrc fuseling incl removing faulty item from lt panel as reqd , sf 63a hrc fuseling incl removing faulty item from lt panel as reqd , sf 100a or125a hrc fuseling incl removing faulty item from lt panel as reqd , sf 250a hrc fuseling incl removing faulty item from lt panel as reqd , sf new 5 or 6 amp piano switch in replacement of faulty item , sf new 5 or 6 amp 3pin socket outlet in replacement of faulty item , sf new 15 or 16 amp piano switch in replacement of faulty item , sf new 15 or 16 amp 6pin socket outlet in replacement of faulty item , rewinding ceiling fan motor , sf 4ft 20w led fitting against faulty fitting , service of 750kva dg set as per specification , service dgset control panel 1250a 4p acb as per specification , repacement ryb ind lamp in dg set panel , repacement digital ammeter in dg set panel , earthing testing in existing earth pits and report submission
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off loadtapchanger on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp