Get complete information related to latest Load Balance Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Load Balance Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Load Balance Tenders.
Tender For providing of annual maintenance service -data center assets - network optimization / wan optimization appliance; network security appliance or network management software; oem authorised service provider,annual maintenance service -data center assets - loadbalancer or virtual loadbalancer software; loadbalancer / application delivery controller; oem authorised service provider,annual maintenance service -data center assets - backup & recovery solution / backup server; backup and replication software backup; oem authorised service provider,annual maintenance service -data center assets - servers / storage / data center infrastructure; storage system / enterprise storage / storage server; oem authorised service provider,annual maintenance service -data center assets - firewall / network security appliance; firewall---ngfw; oem authorised service provider,annual maintenance service -data center assets - virtualization infrastructure / hypervisor management; virtualization & cloud software; oem authorised service provider,
Tender For supply of servers (v2) (q2) , rack server type2 , rack server type3 , blade server , blade chassis solution , san switch 48 port 32g fc , network switch l3 48-port 25g sfp28 , management switch l2 48-port 1g baset , server loadbalancer , installation and configuration cost including all required accessories and connecting cables such as optical fiber cables, ethernet cables, connectors, and other necessary materials
Tender For supply of proposal for annual maintenance contract for pm10 analyzer cmc, filter tape with online data transmission on jspcb/cpcb for hld goods shed for 03 years. a) scope of work:- i) system alarm check (ii) gas flow check (iii) communication check (iv) filter tape replacement (v) pm heads cleaning (vi) check historical abnormal data (vii) calibration of analyzer (viii) replacement of consumables & spares if any (ix) record and report or mom of current maintenance (x) data uploading to spcb for 3 years. c) visit schedule- four visits per year and emergency visits in case of breakdown. the bidder/contractor shall comply with the complete scope of work as mentioned above. submission of offer shall be treated as unconditional acceptance of all scope activities. ]
Tender For supply and installation or urs at various areas of zone south, jodhpur - providing & laying xlpe insulated & p.v.c. sheathed armoured aluminium cable confirming to is :7098 p - i of 1.1 kv with h4- grade electrolytic aluminium conductor confirming to is 8130 of purity >99.6 %, round / flat strip armouring of cables, inner / outer sheath confirming to is:5831 in existing rcc / hume / stoneware / pvc pipe/ open duct/cable trench / cable tray(with cable tie) including testing commissioning etc. as required of following size.10.0 sq. mm x 4 core, supply & installation of unified regulation system (urs) for existing street light that meets the following specification.the system must feature a 240mhz dual core processor with gsm/gprs communication capabilities and support for ota firmware updates.it should come with an internal class 1.0 energy metering system that can provide real time data of crucial electric load parameters along with fault and theft alerts.the urs must include remote load scheduling and control functionalities with a feedback time of less than seconds.the enclosure confirms to ip55 standards,and be fire retardant,weatherproof,and rustproof. the system should use a lightweight protocol for secure ,real-time communication and include cloud based software for comprehensive device management and remote control. it should be able to control single phase 5.5kw and 3 phase street light load upto 8.5kw and should come with 2pole/4pole mcb upto 25a/40a at output for short circuit protection .having a 2-year warranty urs will be installed at site as per direction of engineering incharge. (size 570*520*190mm)
Tender For invitation quotation for data rates of electrical items. - releasing and refixing of 30 mtr polygon highmast pole includes mechanical accessories and lighting arrestor,labour charges, hiring of crane and transportation charges. (excluding foundation work), releasing and refixing of 12/16/20 mtr polygon highmast pole includes mechanical accessories and lighting arrestor,labour charges, hiring of crane and transportation charges. (excluding foundation work), releasing and refixing of tubular/ octagonal/conical poles of height 5 mtr to 10 mtr height. including labour, crane and transportation charges. (excluding foundation work), amc chagres for 180 to 200 kva dg set including a. draining of lubricating oil sump, clean sump, strainer, and filter gauge. b. renewal of lubricating oil filter element. c. refilling the sump with new oil and prime the lubricating oil system.d. check and adjust fan belt tension. e. checking and adjustment of tappet clearance. f. checking and tightening engine breather cap screws. and all materials included, amc chagres for 125 to 160 kva dg set including a. draining of lubricating oil sump, clean sump, strainer, and filter gauge. b. renewal of lubricating oil filter element. c. refilling the sump with new oil and prime the lubricating oil system.d. check and adjust fan belt tension. e. checking and adjustment of tappet clearance. f. checking and tightening engine breather cap screws. and all materials inclueded, amc chagres for 63 to 100 kva dg set including a. draining of lubricating oil sump, clean sump, strainer, and filter gauge. b. renewal of lubricating oil filter element. c. refilling the sump with new oil and prime the lubricating oil system.d. check and adjust fan belt tension. e. checking and adjustment of tappet clearance. and other all material included, hire charges for servicing & maintaining of 3 ton cassette type air conditioner includes fillling of gas, checking of electrical wiring connection for tightness. straighten up to normal position coil fins using comp. inspect compressor motors for proper operation. lubricate shafts bearing and motors.inspect fan for bent blade and correct as necessary, hire charges for servicing maintaining of 2 ton split type air conditioner includes fillling of gas, checking of electrical wiring connection for tightness. straighten up to normal position coil fins using comp. inspect compressor motors for proper operation. lubricate shafts bearing and motors. inspect fan for bent blade and correct as necessary, servicing & maintaining of 10 kva ups system with battery for the period of 1 year includes (i) inspection, diagnosis, component replacement, testing and validation of functional ups units., servicing & maintaining of 5 kva ups system with battery for the period of 1 year includes (i) inspection, diagnosis, component replacement, testing and validation of functional ups units., servicing & maintaining of 3 kva ups system with battery for the period of 1 year includes (i) inspection, diagnosis, component replacement, testing and validation of functional ups units, remote control and monitoring of individual streetlight using lora communication technology a lora-based street lighting system utilizes lora (long range) communication technology to create a low-power, wide-area network (lpwan) for the remote control and monitoring of streetlights. each streetlight node is equipped with a microcontroller, a lora transceiver, and sensors such as ldrs or pir for ambient light detection and motion sensing., supply and installation of electronic timer for streetlights consisting of microcontroller based electronic timer with rtc, 2x16 lcd wit back light, 5 tactile keys, supplying and installation of intelligent three phase centralised control and monitoring system for street lights, the ccms unit should be capable of switching on & off the lights of a particular switching or networked switching points from central control system automatically
Tender For construction of trench wier with intake chamber at node 1 construction of 2 nos of disilting chambers with hopper bottom at node 2a and 2b providing laying jointing and testing of gravity main of gmserw pipe 450mm dia at rd 00 00 to rd 5825 construction of anchor blocks at various rd - remodeling of fis boktu in tehsil kalpa distt. kinnaur (h.p.)(sh:-c/o trench wier with intake chamber at node-1, c/o 2 nos of disilting chambers with hopper bottom at node-2a and 2b, providing laying jointing and testing of gravity main of gmserw pipe 450mm dia at rd 00/00 to rd 5825, c/o anchor blocks at various rd's, c/o cut covers at various rd's, c/o collection chamber at junction of pipe and open channel at node-3, c/o p.c.c. b/wall l at rd 00 to rd 45, providing and fixing electically operated gates, supplying insttalation and testing of communication cabels, supply, installation and testing of artificial intelligence based software "dizio interface" to generate the reports, data and graphical representations, supply, installation, development, testing, configuration, and commissioning of a webbased scada system and providing and constructing control room )
Tender For work contract for assisting in day to day maintenance of communication system [telephone system of plant & colony, pa (public addressing) system, walky talky system, scada (supervisory control and data acquisition), plcc (power line carrier communication) etc] at 2x500 mw, abvtps, cspgcl, janjgir-champa.
Tender For supply, installation, testing and commissioning of dcus/gateways/ allocation of sim network service provider and the arrangement of sim cards to enable reliable medium for two-way communication between smart meter & amp:, hes (head end system) over rf mesh network/cellular network. 1. the dcu/gateway shall be compatible with the smart meters mentioned above. rf mesh network should use 865-867 mhz frequency band. 2. the data acquisition (push/pull) frequency shall be configurable 15 min, 30 min or 60 minutes. it shall push events such as tamper, power off etc. to hes immediately on occurrence/receipt from meters. 3. it shall have provision for the cellular, wifi and ethernet communication for the backhaul tohes. 4. sufficient number of gateways shall be installed in such a way that all the meters are covered in the network efficiently. 5. it shall be capable to handle data of minimum 500 nos. of any type of smart meter (1ph/3ph). it shall be able to communicate with the nearest meters at a distance of at least 300 m, depending on topographical features. 6. communication of the nearest meters with other meters shall be established through appropriate mesh formation. rf mesh shall support self-forming and self-healing features. 7. rfmesh shall support at least 15 no. of hops. 8. the equipment shall be weather-proof and dust-proof (minimum rating: ip54 for indoor and ip65 for outdoor installation). it shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc. 9. it shall have passed the following emc tests from reputed lab: conducted emission, electrostatic discharge (esd), radiated immunity, electrical fast transient (eft) - burst, surge, rf conducted disturbances. 10. rf mesh network shall be established to meet the slas as mentioned in tender document. 11. replacement warranty period shall be 66 (sixty-six) months from the date of supply or 60 (sixty) months from the date of commissioning, whichever is earlier. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply, installation and commissioning of control office equipments (coe) for data retrieval and analytics system for 3 phase electric locomotives as per part 3 of clw spec.no. clw/c-d&d/es/3/0554 issued in april 2024 or latest and scope of work as per annexure- 1.sads comprising large led , daws comprise of high end , remote office communication and asset management , rack 19'' mass rack , power conditioning equipment , smart phone with sads apps with 5g connectivity , modular furniture , transportation, fitment, commissioning of all (sads, daws, furniture, wiring between all these items) including all materials required to connect i.e. electrical wiring, lan wiring, hdmi cables, switches, sockets etc