Get complete information related to latest Load Break Switch Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Load Break Switch Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Load Break Switch Tenders.
Tender For replacement of old and damaged 400 sq.mm x 3.5 core al service cable, supplying and fitting of 630a tpn main switch with din type fuse link, supplying and fitting of wash motor with all fitting, repairing and servicing 630 amp. panel board with fasd - replacement of old & damaged 400 sq.mm x 3.5 core al service cable, supplying and fitting of 630a tpn main switch with din type fuse link, supplying and fitting of wash motor with all fitting, repairing and servicing 630 amp. panel board with fasd starters for operating of 167 h.p. motor pump set, rewinding, repairing and re-conditioning of 167 hp ,440 volt,50 c/s star delta 3-phase sq. cage induction motor and repairing, overhauling & servicing of 167 hp pump -01 set complete at clear water p/plant, repairing and servicing of 200 amp. panel board for operating of 25 h.p. vt motor pump set, special repairing overhauling of 25 hp vt pump and allied works at intake well rajpara of haroraidih group of village rural pipe water supply scheme.
Tender For corrigendum : repairing of defective/faulty 11 kv rmus, including replacement of loadbreakswitch, filling of sf6 gas, replacement of faulty bushing, etc., installed at various locations of indore and ujjain city under mppkvvcl indore.
Tender For automatic star delta starter control panel for 10 hp submersible pump, fully automatic with digital ammeter and voltmeter, power supply suitability is three phase/415 v/ 50hz, thermal bimetallic relay for protection against overload or single phasing and severe unbalanced load, non compensate type capacity is 20 a, overload relay range 13.2 - 20 a, contactor rating current (a) is 20 a, overall dimension (lxwxh) is 175mm x 150mm x 90mm, material and thickness of ms sheet used is m.s sheet 1.6mm thick, color of paint finish is grey, auto manual switch position selection switch type is 3 position(auto-manual), availability of test report from central govt/nabl/ilac accredited lab to prove conformity to specification. similar to bch 10 hp starters control panel forsubmersible pump model: cpsdeynbl2. preferrable make: l&t, havells, subtech, siemens, bch and crompton. ]
Tender For bid to ras bid to ras bid to ras supply of rrc for repairs overhauling di dr of starters fitted onboard in ships and yard crafts at nsry kar b b -repair renewal of main contractor assembly , repair renewal of olr , repair renewal of auxiliary contactor , repair renewal of control circuit cabling , renewal of lugs and sleeves , repair renewal of star delta timer relay , buffing and painting of panel box , repair replacement of four way push release rotary hand change over , removal refitment of panels , repairs renewal of mccbs , refurbishment of panel box with closing butterfly nut gland plate renewal , stw and final trails of repaired overhauled starters
Tender For tender for supply of periodical maintenance and operation of electrical and mechanical installations involving operation , repairs and maintenance , attending to complaints/faults/ breakdowns and taking rectification action , ensuring serviceability/satisfactory working condition of the systems , carrying-out preventive maintenance , maintenance of records/ documents etc. under this contract on all working days including saturdays , sundays and holidays as per tender specifications , terms & conditions by providing/engaging following minimum number of man power i/c reliever. (a) highly skilled (sr. supervisor) - 1 nos. (b) highly skilled (supervisor) - 1 nos. (b) skilled data entry operator - 1 nos. (c) skilled technician - 14 nos. i/c relievers (d) unskilled helper - 14 nos. i/c relievers total minimum manpower i/c reliever- 31 nos. note- relievers shall do duty of electrician//helper as per site requirement. , carriage of diesel (4 drums 200 ltr each) from petrol pump (any petrol pump among located in kushinagar as decided by eic-aai) to the sub station (dg set room) which includes hiring of vehicle loading & unloading of empty and oil filled drums at site. note - empty drum will be provided by aai. , servicing of l&t make , model u-power omega air circuit breaker 630/800 a through l&t service engineer / l&t authorized service engineer including carrying out of following works- racking out & removal of acb from electrical panel , cleaning all parts for dust deposits foreign particles etc , degreasing the various parts of acb. cleaning all parts with cleaning agents such as crc 2-26 checking the various relay/protection settings and other setting of acb contacts , releases etc , checking the hardware for wear & tear , checking of termination & tightness , checking for all hardwares for its presence , replacement of spares / accessories for defective / worn out items (supply of spares / accessories required for healthiness of acb are in aai scope) , regreasing of the acb parts as recommended by oem , refixing the acb , testing and observance for normal operation of acb complete as required. note - service report to be submitted in l&t letterhead / l&t authorise service dealer letter head. , one time servicing , maintenance , testing , overhauling of complete out door type package/ compact sub-station of m/s c & s make through oem service er. or oem authorised dealer /service er.only as per the oem recommendation and scope of work of tsc/ scc of the contract. pss is comprising of following- ht panel - 12kv , 630 a , 21ka/3sec , 2way non extensible sf6 insulated rmu comprising of 01 nos. 630a manual loadbreaker switch and 01 no. 630a manual vaccum circuit breaker. transformer - 11kv/0.433kv , 400 kva oil type transformer -01 nos. lv componenet - 4 p , 630a , drawout acb - 01 no. 3p 400a mccb for capacitor panel capacitor panel - apfc 200kvar capacitor panel- 01 nos. pss is comprising all above i/c metering , relay etc complete. oem service er. has to submit the relay calibration report along with service and maintenance report of transformer , rmu , ht & lt panel and capacitor panel i/c healthiness report after service and other report if any as per oem recommendations complete. , carriying out the dehydration of transformer oil of 400 kva transformer (make - kotson) in 400 kva c &s pss at site i/c transportation of dehydration machine , di-electric strength test (bdv value) of oil before and after dehydration at site and submisstion of report as per requirement. note - the transformer having capacity of 330 ltrs of tranformer oil. , supply of new transformer oil conforming to is-335 in non-returnable barrel as per requirement. , one time servicing , maintenance , testing , overhauling of complete outdoor type package/compact sub-station of m/s sudhir power make through oem service er or oem authorised dealer /service er.only as per the oem recommendation and scope of work of