Get complete information related to latest Load Cell Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Load Cell Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Load Cell Repair Tenders.
Tender For custom bid for services - repair of mps 12 unit part no mkld 466229 050 tu sl no 050100745; details of items. (a) description (b) part no mps-12 unit mkld.466229.050 tu (c) make russia (d) si no. 050100745 (e) year of purchase 2016. 2. purpose. the mps-12 unit, pt. no. mkld.466229.050 tu is microcomputer based equipment designed to display aircraft radar data and status of radar equipments on the screen. 3. defects. mps-12 unit, pt. no. mkld.466229.050 tu, si no. 050100745 has been loaded on repair order vide repair order k/ro/k31/2024/2148 dated 06 apr 24 by mo (goa). during function checks of the unit found display becomes white after 5 minutes of operation. further unit confirmed defective during workshop test. 4. repair. (a) identifying the defect utilising the standard electrical and electronic tests/ fault analysis techniques available in the industry. the work is required to be undertaken by qualified technicians. support document for qualified technicians be submitted by the firm. the repair methodology/ repair process undertaken to identify defective component be submitted. (b) replacement of defective bds by utilising mil standard serviceable spares supplied by oem/ oem authorised vendors. suitable certificate of conformity from firm be submitted. further, colour photographs/ video recordings of components replaced during the repairs be submitted with old items replaced. (c) submission of report regarding details of testing, if any, carried out for mps-12 unit in the firm premises. in case such test has been undertaken at firm nromioca thon details of the equipment utilised for testing and qa clearance/ ca applicable) of the test set be submitted. (d) association of firm's engineers for functional, integration anu user acceptance trials at nay (goa). (e) certificate of origin from firm be provided (if imported spares are used). (f) warranty certificates from firm be provided (as applicable). (g) inspection by the yard qa would be undertaken post completion of repairs during user acceptance trials which includes functional checks on aircraft, inspection for transit damage/ visual checks for abnormalities, correctness and completeness of item along with valid documents as per repair order. (h) the item will be tested on sk-801 radar test bench at workshop. if the item fails during testing, the firm agrees to undertake repairs of the item on foc basis irrespective of time elapsed since supply of item to indian navy..
Tender For short refit (sr 26) of ins tarangini (o/l) - summary of quotation, servicestotal cost of dry dock hire charges and other admin & general services quoted in the boq, cost of repair part :-(a) total cost of hull work package, (b) total cost odf engineering work package, (c ) total cost of electrical work package, gst on serial 1.01 to 1.04, total budgeary cost of spares, gst applicable for 1.06, any other taxes & duties, miscellaneous (not included in any of the serial above), gst if any on serial 1.09
Tender For supply of periodical repair maintenance and operation of power supply , operation and maintenance of roof top solar plant , repair of earth pits , supply of transformer oil , dehydration and filtration of transformer oil , provision of silica gel , service charges for locating pin pointing of fault in lt cable , service charges for locating pin pointing of fault in ht cable , supplying and making indoor cable end termination 35 sq mm , supplying and making indoor cable end termination 185 sq mm , supplying and making straight through cable jointing 35 sq mm , supplying and making straight through cable jointing 185 sq mm , servicing checking and testing of lt circuit breakers upto 1600 amps , servicing checking and testing of lt circuit breakers above 1600 amps and upto 3200 amps , servicing checking and testing of 11 kv ht circuit breakers upto 800 amps biecco lawrie make , servicing checking and testing of 11 kv ht circuit breakers 630 amp rmu with sf6 insulating medium , supply of the following spares jaw contacts 1 set upto 1600 a , supply of the following spares pole assembly include 1 fixed contact upto 1600a , supply of the following spares jaw contacts 1 set above 1600 a and upto 3200 a , supply of the following spares pole assembly above 1600 amps and upto 3200 amps , inspection servicing testing and calibration of idmt relays , inspection servicing testing and calibration of idmt relay , inspection servicing testing and calibration of protection relays , inspection servicing testing and calibration of digital protection relays , transformer oil leakage repair of lv side of transformer upto 500 kva , transformer oil leakage repair of lv side of transformer above 500 kva upto 2000 kva , servicing checking and testing of the following 250 kva servo for mssr , complete item of cpwd schedule of rates electrical 2022 ) /bid number : gem/2025/b/6662944 * /dated: 09-09-2025 & & / bid document 1 / 23