Get complete information related to latest Load Indicator Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Load Indicator Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Load Indicator Tenders.
Tender For supply of twin path round endless polyster sling with covemax cover, fiber optic & over loadindicator having full signal part anti abrasive protective 1/2 mtrs. 2 nos. fitted on single part cap=3 tons,effective length=2.5mtrs., cir length=5mtrs.,width=50mm.along with proof load certificate issued by agency/competent person approved by directorrate of industrial safety and health maharashra state.slingest,slingmax,e.e.karachiwalla&co. and eletech [ warranty period: 30 months after the date of delivery ] ]
Tender For comprehensive annual maintenance contract of mechanica make safe loadindicator (sli)system of gottwald new design 140t break down crane based at gondia for 03 years
Tender For corrigendum : tender for the supply of various equipments - muffle furnace, "al2o3 sample plate, al2o3 furnace door block, protection glove, crucible clip, crucibles, karl fischer titrator, "titration vessel, detector electrode with lead, generator electrode (with frit) with lead, desiccant tube and cap, injection septa (pack of 10), gas tight syringe 1.0ml , luer needle 17-gauge, dust cover, results manager software, main power pack, fuse, karl fischer titration reagent(s), nist calibration standard, refrigerated centrifuge (bench top), bottles/falcon tubes/adapters for 0.2ml tubes, one set of other items (adapters) required for improving the applicability/system performance should to be quoted, nitrogen evaporator, evaporation tubes, gas fuse , water purification system including water softner, cartridges, filters etc. for , bomb calorimeter, "ignition wire, cotton thread, combustion crucible, bomb, nist certified benzoic for calibration, any other accessories required for analysis of food samples., gas chromatograph with ecd, tcd, fid with autosampler, "pesticide column (30 m x 0.250mm x 0.25m (5ms (95% dimethyl-, 5% diphenyl-polysiloxane / 1ms (100% dimethyl polysiloxane or equivalent) 100 mm column for fatty acid profiling with main concern of trans fatty acid application, column for cholesterol application, stationary phase: 95% dimethyl-, 5% diphenyl-polysiloxane (30 m x 0.250mm x 0.25m),, "vial sets (1, 2 ml, crimp type, amber and clear glass), vials (10, 20ml crimp type with cap & septa), 300/500 l recovery vials, septa ptfe/silicone (for 1, 2 ml vials), septa ptfe/silicone (for 10, 20 ml headspace vials), ergonomic crimping tools for different vial types, ergonomic decapping tools for different vial types, head space vials 10,20 ml capacity, suitable syringes for quoted autosampler, suitable headspace syringe /valve/loop, quechers kits for pesticides and herbicides in following matrices:, matrices with high fat, matrices with high water content, matrices with high pigmented, spe cartridges for water., ultra performance liquid chromatography (uplc) with photodiode array (pda), fluorescence (fld) and refractive index detector (rid), sample vials with 1.5 ml or greater, stainless steel ultra sonic bath with the capacity of 5 l or more, with time setting (min) 1-30min or continuous operation with led and push button (should be ip 33 protection class) for sonication of spare parts as well as solvents, fittings, frits, ferules and tubings, tubing cutter, solvent bottles (1000 ml capacity), solvent filters (glass & ss both, compatible manual syringes -10 l, 20 l, 50 l, standards for hplc calibration for pda, ri and fluorescence detector, consumables required for each detector must be provided., "hplc columns: one each of, c8 = 250 4.6 5m c18 = 250 4.6 5m, cyano = 250 4.6 5m. amino = 250 4.6 5m, phenyl = 250 4.6 5m. silica = 250 4.6 5m., all columns must be supplied with respective guard column and holder. ", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate., uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate., ft-ir with atr & liquid cell, " hydraulic press with kbr die and pellet holder, suitable mortar pestle (dia 5-6 cm), suitable portable de humidifier to maintain 30- 60% rh, temperature and relative humidity digital indicator with calibration certificate from iso 17025 accredited lab., reference nist standard polystyrene film (0.3 mm) over the range of 3800 cm-1 to 650 cm-1., abbes r
Tender For supply of set of toh kit for maintenance of kbil make air dryer. one set consisting of 12 items, qty/ ad= 24 nos. sr. no. description kbil part no. qty. / ad 01- final filter element i.3.3085/6 01 drg. no. 1.4.3093 02- knorr k ring a54953 02 03- o ring a40125/13 02 04- o ring a52320 01 05- o ring a91453 02 06- scraper ring a97200/5 02 07- o ring b44910 02 08- knorr k ring 462422 02 09- sealing ring 459633 01 10- o ring b55436 04 11- o ring 0124266/1 04 12- humidity indicator 13685 01 repair kit (06 items) [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply, erection, testing and commissioning of hydraulic spring testing machine (coil scragging and load deflection testing machine) for compression/deflection testing and cycle testing of helical spring with respective load for all size of helical spring of electrical loco bogies of wap1/wap4/wag5/wag7/wap7 and wag9 locomotive along with digital loadindicator and length measurement device (digital linear scale c/w read out console) and data retrievable and storage unit as per els/ed technical specification no: sr/els/ed/m1/spring testing/002, dt:16.08.24. warranty is 24 months from date of successful commissioning of the machine. ]consignee sr.dee/rs/els/ed, srtamil nadu1.00 numbersinspection details stage inspection not required2 650306610055amc (y) non stock--- yesconsigneeinr description :camc : post warranty comprehensive annual maintenance charges ( after 2 years of free warranty period ) : annual maintenance contract rates for the next five years after completion of warranty period to be given in the offer. firm to quote separately for individual year ie year 1. tab ( for 3 rd year). year 2 tab ( for 4 th year) , year 3 tab ( for 5 th year) ,year 4 tab ( for 6 th year) and year 5 tab ( for 7 th year) - clause no. 1.11 of els/ed technical specification. firm should quote actual rate of camc in the bid. discounted rate as per npv will be generated by the ireps system for ranking purpose. the rate mentioned in the po will be considered for annual maintenance contract by the consignee after completion of warranty. firm will be bound to accept the annual maintenance contract if consignee desires to go with annual maintenance contract after warranty period else wbg will be encased. annual maintenance contract charges will beprocessed as per the regular procedure through revenue allocation. [ warranty period: 2 years, annual maintenance contract period: 5 years, rate of discounting: 10 % ] [ warranty period: 2 years, annual maintenance contract period: 5 years, rate of discounting: 10 % ] ]