Tender For equipments for electrical engineering lab.--, , rlc kit, , water analyzer, , solar energy panel - kt, , four point dc motor starter, , single phase transformer, 230/230v, 230/115v, 3kva with tapping at 10%,25%,50% and 75% housed in steel box with educational type terminals provided with control panel (for oc and sc test) consisting of following accessories, , dc compound motor, , single phase, , electrodynamometer wattmeter, , digital portable lcr meter, , single phase variac, , three phase variac, , phase sequence indicator, , synchroscope, , rheostats of various ranges, , meggar (two of each rating), , different types of overhead line insulators(each one), , different types of underground cables, , parallel inverter using scr's (memurray bedford), , step up chopper trainer kits with required capacity of (30v/2a and 220v/5a ratings), , battery charger experimental kit using scr, , experimental kit for speed control of dc series motor (scr based), , synchronous motor, , dc servo motor speed torque characteristics kit, , ac servo motor speed torque characteristics kit, , ac position control system kit, , dc position trainer kit, , synchro transmitter and receiver kit, , linear system simulator (open loop & close loop system of first order & second order systems), , cut sections and charts, , hrc fuse, , d.o.l.. starter (for induction motor) trainer kit with overcurrent relay, , three phase power factor meters, , insulation tester, , single phase wattmeter, , clamp ammeter kit, , dso, , sr, d, jk and t flip-flop (each two), , common emitter transistor set, , analog to digital converter interface card, , 4 digit seven segment display interface card, , dac kit, , temperature measurement & controller card, , 8086 microprocessor trainer kit for study, , intel 8051 microcontroller kit with data card, , nd converters experimental kit (adc 0800 series), , led display kit with card, , lcd display kit with card, , monkey wrench/pipe, , wrench, , chisel (farmer chisel & cold chisel), , wire stripper, , hand drill, , drill bits-metal bit reamer, carpentry bits, flat wood bit and masonry bit., , tumbler switch, , dpic switch, , main switch, , sub mail 1 switch, , 2 way 6a switch, , 1 way 6a switch, , single pole double throw, , single pole single throw, , triple pole switch, , metal conduit pipe with junction box, , metal bend, , pvc casing and capping, , pvc bend, , batten lamp holder, , switch boards with socket outlets, , 7/20 swg power wire, , 3/20 swg phase wire, , 3/22 swg neutral wire, , 1/18 swg earthing wire, , flexible cable, , try square, , coil winding machine, , card dynamo for the purpose of armature winding, , 3- phase squirrel cage 2hp induction motor for the armature winding purpose, , small battery charger for assembly and testing purpose, , alarm bell for assembly and testing purpose, , inducting relays for assembly and testing purpose, , coil winding varnish coated wire of suitable gauge
Tender For corrigendum : purchase of sports exercise physiology lap equipments - cardiopulmonary exercise testing system system should be compact can be used in laboratory operation and low maintenance costs and easy servicing. system should be state of the art computerized telemetry breath test analyzer for on-line breath by breath measurement of exercise test of respiratory system to measure following parameter: time, ve, bf(rr), hr, feo2, feco2, peo2, peco2, vo2, vco2, ve/vco2(eqco2), ve/vo2(eqo2), rq(rer), vd/vt, vo2/kg, vo2/kg/hr, met, watt(work), hr, ttot, ti, te, ti/te, ti/ttot, pef, pif, br, vet, sum, tv/te, o2 kinetics, oxygen deficit, oxygen debt parameters and indirect calorimetric. wireless hr recording system, indirect cardiac output by wassermann algorithm system should comply ats and ers guide line and it should be ce certified., iso certified system should have automatic ambient conditions measuring system. system should work under temperature range 0 to 50 celsius. system should have facility for automatic calibration of analyzers. volume transducer calibration with precision calibration syringe. system should meet following technical specification flow rate measurement: measuring headpiece should be either through turbine /dvt/ pneumotach and dead space less then 40 ml, it should not be affected by humidity , flow range +/- 18 l/s and accuracy 2% oxygen analyser : should be either electrochemicalcell/paramagnetic and measurement range 0- 100 %,response time t90 100 ms and accuracy +/-0,04 % and- resolution 0,02 %carbon dioxide analyser : should be ndir (infraredabsorption) and measurement range 0 - 10 %,-response time t90 90 ms , accuracy +/- 0,04 %, andresolution 0,02 % software should support latest windows or latest andin corporate customized predicted normal equations.software should be capable of changing graphics displays during real time testing. system should have facility for automatic treadmill or bicycle ergo meter control. should be supplied with software, standard accessories for operation manual carrying case for field use. system should be supplied with latest data acquisition system, deskjet printer and ups. system should comply en iso 13485:2003, en iso 9001:2000, ec certificate93/42/eec, programmable treadmill running machine with user terminal (display &keyboard) stand- alone and remote control via rs232 running surface: l:170 cm (minimum), w: 65 cm (minimum) maximum possible load: 200 kg (440 lbs) speed range: 0-40 km/h elevation: 25% (14 maximum elevation) motorized adjustment, reverse belt rotation. motor system 3.3 kw, single phase ac motor, maintenance free and brushless power transmission: frequency inverter, poly v- belt, very quiet operation safety system: emergency-off safety stop switch (safety lanyard with actuator, pull cord and clip); potential equalization bolt; transformer for potential-isolation from the mains ambient condition: temperature: +10to +40 degrees c, humidity 30 to 70% display (resolution): lcd display heartrate monitoring: wireless transmitter; the treadmill should be able to interface with well-known compatible metabolic gas analyzer as per standard and custom exercise protocols different programs safety harness-1. indispensable accessory for stress testing, accident prevention and for the general safety of athletes.2. safety arch with different heights and widths to fit all running machines.3. an emergency stop at the crossbar of the safety arch allows automatic stop of the running belt in the moment a fall occurs.4. the harness and chest belt (available in 5 sizes: xxs, s, m, l, xl) secure the subject and prevents falling over to the front.5. chest belt straps do not pinch or restrict the athlete", programmable ergometer functional design and excellent stability, load up to 160kg. easy to use saddle, handle bar and pedals speed independent and dependent power control handle bars are easy to change to suit different tests, rotatable by 360 degrees. mechanical/motor-a
Tender For corrigendum : purchase of biomechanical lab - force platedimensions (w x d x h) in mm : 600 x 400 x up to 50 number of axes for force measurement: all 3 axes. x,y,z plate should be portable in naturesensor type: piezoelectricsampling frequency-(hz) =1000 hz or more force measured on each axis-fx,fy: 2,000 newton or more, fz: 10,000 newton or more hysteresis- (%fso): 0.5 linearity (%fso) 0.5 crosstalk (%) : 2water resistance rating: ip 50 or better.should be inclusive of installation.should be supplied with carrying case for 2 plates and noise free ups for on-ground assessment. the carrying case should be strong and sturdy.should be able to accommodate portable force plate 9286 ba, daq box 5695 and connecting cablesshould be able to protect the equipment from rain, impact and dust, should have rollers to move easilyshould be able to accommodate an ups also., isokinetic dynamometershould be able to access/test various joints in isolation should be able to meet requirements to test sports personsshould be able to test in different resistance modes such as isokinetic (concentric-concentric, concentric-eccentric ,eccentric, concentric ,and eccentric-eccentric), isotonic, isometric, and passive protocols should include options for angles, hold-times, rest period, repetitions, and sets. the system should be able to test all the major body segments and joints such as shoulder, forearm, elbow, wrist, hip, knee, and ankle.should have adjustable range of motion stops in full 360 degrees.should have 360-degree rotation for the force arm (connecting dynamometer to the pedal) to have wide range of motionshould be able to accommodate different athletes with varying height and weight with provision for seatbelt harness for better stabilitythe dynamometer or chair should be movable to accommodate different athletes for quick set-up and better usability with locking clamps for securing the system in place for testingshould be able to do gravity correction when the limbs are positioned with the lever arm on the dynamometerthe software should be provided to analyze the raw data and export the raw and processed data in different file formats such as excel, text, etc. the software should provide detailed report for various testing protocols such as individual test for joints, data/graph overlay for comparing pre and post testing, repeatability, progress, multi-session.should be provided with latest compatible workstation/laptop of reputed brand like hp, dell (latest generation) processor, minimum16gb ram, windows os 11, and laser printerconcentric speed: 500 deg/sec or more eccentric speed: 500 deg/sec or more concentric torque: 500 ft-lb (678nm) or more eccentric torque: 500 ft-lb (678 nm) or more isometric torque: 500 ft-lb (678 nm) or more isotonic torque: 500 ft-lb (678 nm) or more isotonic torque as low as .5 ft-lbfeedback formats: roadway, interactive line, interactive path, reaction training, proprioception training, breakout, and pong.torques. time, torques. angle, torque bars, work bars, power bars. it should be possible to use mechanical stops even with custom patterns (important for safety in research)the same attachment should be usable for left and right side of subject for consistencies in data.should be certified and approved by ce/eu medical devices directives or usfda, nord boardit should be portable and should have 2 load cell sensors per unit with easy to attach hooks pivoting 360 degrees joint improving sensor accuracy it should have knee position indicator for replication of test position in each time. should have sample rate per sensor: upto 400hz, capacity per sensor: 100 kg/980-1000n safe over load per sensor: 150kg/1500n, max over load per sensor: 200kg/ 2000n, resolution: 1n and sensitivity: 22.0+/-mv/v. should have rechargeable battery & battery life should be100 active hours approx. should have working temperature range 5-40 c. (all weather proof) latest upgradable software should have both wired & wireless conne
Tender For supply of separately excited motor with electrical load arrangement , 3dc series motor with mechanical load arrangement , 33 ph induction motor squirrel cage with mechanical load arrangement , 33 ph induction motor slip ring with mechanical load arrangement , 33 ph induction motor slip ring with slip power energy recovery arrangement , 33 ph induction motor with electrical load arrangement , 33 ph synchronous motor with electrical load arrangement, 3 ph virtual grid , 31 ph induction motor squirrel cage with mechanical load arrangement , 31 ph synchronous motor with mechanical load arrangement , 3digital storage oscilloscope , 3lpf upf wattmeter , 31 ph transformers isolation transformer , 31 ph transformers step down transformer , 31 ph transformers step down transformer with additional tap at 86 6 , 31 ph transformers auto transformer 2kva , 31 ph transformers auto transformer 5kva , 3kelvin s double bridge , 3wheatstone bridge , 3schering bridge , 3maxwell s bridge , 3hay s bridge , 3wien s bridge , 3lvdt arrangement , 3 power diode schottky diode diac triac scr thyristor mosfet igbt , 31ph half wave scr thyristor rectifier r r l load freewheeling diode , 31 ph full wave full bridge scr thyristor rectifier rrl freewheeling diode , 31 ph full wave scr thyristor rectifier with centre tapped transformer , 31 ph full wave scr thyristor semi controlled rectifier , 33 ph half wave scr thyristor rectifier and freewheeling diode arrangement , 33 ph full wave scr thyristor rectifier with freewheeling diode arrangement , 31 ph half bridge igbt inverter , 31 ph full bridge igbt inverter , 33 ph full bridge igbt inverter rrl load freewheeling diode arrangement , 33 ph 3 level diode clamped igbt inverter with variable r r l load , 33 ph 5 level diode clamped igbt inverter with variable r r l load , 31 ph to 1 ph igbt cycloconverter with variable r r l load , 33 ph to 1 ph igbt cycloconverter with variable r r l load , 33 ph to 3 ph igbt cycloconverter with variable r r l load , 3igbt based buck converter with variable r r l load , 3igbt based boost converter with variable r r l load , 3igbt based buck boost converter with variable r rl load , 4aiot autocar ii , 4ai mavin , 4ups 1 , 4ups 2 1function generator, 1power supply, 1digital storage oscilloscope, 1lead lag compensation network experiment setup, 1synchro transmitter receiver as error detector, 1dc motor speed control with software, 1control system lab basic experiment setup , 1linear variable differential transformer lvdt , 1test and measurement,data acquisition daq tariner kit, 1digital lab work bench , 1floating carriage diameter measuring micrometer, 1mild steel flapper nozzle trainer, 1process control trainer setup with plc interface, 1speed sensing transducers: , 1temperature sensing transducers min 5 tranducers with signal conditing , 1control valve characteristis quick opening, liner and equal percentage trainer, 1daq device multifunc i o usb 2, 1ultrasonic digital distance meter trainer kit, 1platform for the study of load cells their application for weight measurement, 1dc ac potentiometric error detector, 1robotic arm completely programmable and controllable through pc, 1alloy rotary inverted pendulum motion control interface with matlab scilab , 1tachometer digital analog, 1supervisory control and data acquisition scada , 1dead weight tester, 1pressure transducer test set, 2laurents half shade polarimeter with source , 2gm counter , 2newtons ring apparatus with travelling microscope , 2sodium vapour lamp with transformer and lamp box, 2hall effect experimental set up, //bid details 2 / 71
Tender For supply of 8051 microcontroller development board single board system , 8051 microcontroller development kit 1 , 8051 microcontroller development kit 2 , basic robotic components kit , calibration of pressure guage dead weight , cro 0 20 mhz dual trace, dual beam with component tester1 , cro 0 20 mhz dual trace, dual beam with component tester2 , cro 0 20 mhz dual trace, dual beam with component tester3 , different types of pressure measuring , different types of transducers , dual power supply , educational programmable robotic arm for inspection 1 , educational programmable robotic arm for inspection 2 , electro hydraulic trainer kit 1 , electro hydraulic trainer kit 2 , electro hydraulic trainer kit 3 , electro hydraulic trainer kit 4 , electromagnetic flow meter 1 , electromagnetic flow meter 2 , electromagnetic flow meter 3 , flow measurement kit , force measurement kit , function generator with ttl output 2 mhz 1 , function generator with ttl output 2 mhz 2 , measurement of temperature kit , measurement of vaccum by mcleaod guage , potentiometer as an error detector trainer kit. , programable raspberry pi microcontroller kit 1 , programable raspberry pi microcontroller kit 2 , programable microcontroller 8051 kit , programable raspberry pi microcontroller kit for 4 digit 7 segment led display , programable raspberry pi microcontroller kit for smart street light system. , programmable logic controller trainer kit 1 , programmable logic controller trainer kit 2 , prototype microcontroller raspberry pi kit for agriculture application 1 , prototype microcontroller raspberry pi kit for agriculture application 2 , shaft power measurement trainer , sound measurement trainer , synchro transmitter receiver trainer kit , torque measurement kit , trainer kit of ac position control system. , trainer kit of dc position control system. , trainer kit of first order and second order system. , trainer kit of measure level by using capacitive transducer. , trainer kit of measure flow using ultrasonic electromagnetic rotameter , trainer kit of measure himidity using hygrometer. , trainer kit of measure presure using burdon tube pressure guage. , trainer kit of measure resistance using wheastone bridge. , trainer kit of measure sound level by using sound meter. , trainer kit of measure speed using stroboscope. , trainer kit of measure temperature using rtd etc , trainer kit of measure weight using strain guage load cell , trainer kit of on off, pi, pd, pid temperature controller system 1 , trainer kit of on off, pi, pd, pid temperature controller system 2 , trainer kit of plc based pulse counting using limit switch 1 , trainer kit of plc based pulse counting using limit switch 2 , trainer kit of potentiometer as an error detector , trainer kit of standard test signal generator , trainer kit of stepper moter , trainer kit of syncro transmetter, control transformer , trainer kit of temperature control system 1 , trainer kit of temperature control system 2 , trainer kit of test performance of r 2r resistive , trainer kit of traffic light control system , trainer kit of verify truth table of gates. //bid details 2 / 53
Tender For tender for supply of remote monitoring and protection panel for 4 da sets rmpp , maint free battery , backup power supply sub system , signal conditioning module , logic controller module for me lcp , logic controller module for mer , logic controller module for da lcp , temp signal conditioning module for thermo couple , light bar pcbs for shaft rpm , speed control pcb , main control pcb , temp measurement pcb , over load relay 3-5a , rpm indicator 72 sq mm 4-20 ma with dial , pressure transmitter 4-20ma dc 0-6 bar , rotary switch , battery 12v