Web Analytics Made Easy - StatCounter

Load Resistor Tenders

Get complete information related to latest Load Resistor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Load Resistor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Load Resistor Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :44231929 Due date: 13 Jul, 202613 Jul, 2026 NA
Tender For corrigendum : supply of various consumable material at emd -1 lighting dept. stps. - flat cable 3 corex4 sqmm with copper conductor for submersible motor, flexible copper wire 1 corex2.5 sqmm (36/0.3 mm)1100v(1 coil is equal to 90 meter), flexible copper wire 1 corex1.5 sqmm (22 / 0.03) voltage grade up tp 1100 volt conf to is- 694, copper cable 2 cx1.5 sqmm, pvc twin wire 2.5mm sqr., self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm width x 7.5 mtr length x 0.125 mm thickness, of red colour, self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm width x 7.5 mtr length x 0.125 mm thickness, of yellow colour, self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm width x 7.5 mtr length x 0.125 mm thickness, of blue colour, self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm width x 7.5 mtr length x 0.125 mm thickness, of black colour, self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm width x 7.5 mtr length x 0.125 mm thickness, of green colour, porcelin kit kat fuse 16 amp, porcelain kit kat fuse 63 amp, 415 v , ac, porcelain kit kat fuse 100 amp, 415 v , ac, porcelain kit kat fuse 200 amp, 415 v , ac, din rail mounting channels, ring spanner set model 1812 taparia make, double ended spanner set dep 12, adjustable screw spanner size 8" (200 mm) p.no.1171-8 p, screw driver (tester) taparia product no: 818.special with neon bulb, generally confirming to is 5579-1985 grade - ii, yellow handle,, taparia combination plier, product no.1621-8,210 mm, digital insulation tester, range-0-2000 m-ohm, selectable test voltage-250/500/1000 v dc with rechargeable battery, digital clamp on meter lcd display with backlight, 3-3/4 digit., alluminium ladder self supported a type having 05 feet length, long nose plier insulated with thick c.a. sleeve,165 mm length, taparia make tool, allen key set, product no aki 10, allen key set mm size (09 piece) 1.5,2,2.5,3,4,5,6,8,10 mm, hand drill machine size 13mm, hand grinder machine., aluminium tube terminals10.0 mm2, m.6, aluminium tube terminals16.0 mm2, m6, aluminium tube terminal 35 sqmm,m 8, aluminium tube terminals50.0 mm2, m10, aluminium tube terminals70.0 mm2, m8, aluminium tube terminals95 .0 mm2, m10, pin terminal 1.5 mm2, pin terminal 2.5 mm2, aluminium in line connector25.0 mm2,, 35mm alluminium in line connector als-2"dowell", aluminium in line connector 70 mm2, 95 sqmm crimping alluminium type in-line connectors cat no: hai-15 hex make, crimping tools capacity: 10 mm2 to 185 mm2., crimping tools, capacity: 6 mm2 to 50 mm2., alluminum ring type lug 25 sq. mm, pvc saddle 10 mm, pvc saddle 15 mm, pvc saddle 20 mm, pvc saddle 32 mm, multistrend copper flexible wire 1 core x 4.0 mm2, (7 strendes) pvc (double) insulated, without armourr, 1.1kv grade (100m/coil)

CTN :45664072 Due date: 28 Jul, 202628 Jul, 2026 NA
Tender For supply of load resistor to primary voltage transformer to spec. clw/es/3/0024 alt.- a, and str no. clw/2022/eldo/e/str/0139 rev- 0 [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

CTN :45608455 Due date: 25 Jun, 202625 Jun, 2026 NA
Tender For procurement of lab equipments for electrical and electronics engineering department - procurement of lab equipments for electrical and electronics engineering department., single phase tranformer: single phase transformer rating: 1 kva, 50 hz input: 230 v ac output: 115 v ac type: air-cooled, single-phase step-down transformer properly insulated input and output terminals brought out for safe operation, three phase transformer: rating: 3 kva input voltage: 415 v ac, 3-phase output voltage: 230 v ac, 3-phase frequency: 50 hz winding material: copper wound insulation class: class b or higher duty: continuous duty suitable for laboratory use bench/floor mounted suitable for laboratory operation. all winding terminals shall be brought out to insulated terminals and enclosed within a protective outer cover for safe laboratory operation , acidity test kit ethyl alcohol sodium carbonate solution universal indicator solution laboratory-grade test tubes droppers colour comparison chart for test result comparison chemicals supplied in labelled containers with safety instructions suitable for laboratory educational and testing applications, loading rheostat 3 phase: rating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided , loading rheostat 01 phase: type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability , single phase resistive load type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability , three phase resistive load: rating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided , three phase capacitor bank: 3-phase capacitor bank rating: 2 kvar voltage: 440 v ac frequency: 50 hz heavy duty self-healing capacitor units powder coated ms enclosure compact panel mounted/floor mounted construction proper ventilation arrangement to be provided capacitor duty contactor/switch to be provided fuse/mcb protection to be provided discharge resistors to be provided for safety proper earthing arrangement provided , on / off control of lamp using solid state relay kit type : solid state relay (ssr) trainer kit control/input voltage : 12 v / 24 v dc or up to 30 v dc output load voltage : 230 v ac, single phase load control : on/off control of ac lamp load solid state relay based switching circuit opto-isolated input control built-in ac lamp load manual on/off switching arrangement led indication for input and output status

Central Government And Public Sector

CTN :45597647 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For supply of load resistor to primary voltage transformer as per specification. no. clw/es/3/0024/a or latest specn: clw specification. no. clw/es/3/0024/a or latest [ warranty period:30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

CTN :45541202 Due date: 23 Jun, 202623 Jun, 2026 NA
Tender For purchase of tanche - lab equipments for eee and ece department - purchase - lab equipments for eee department electronics lab, single phase to single phase cyclo converter kit single-phase bridge cycloconverter power devices: scr/triac based input supply: 230 v ac, 50 hz step-down isolation transformer 230 v / 12 v output: 12 15 v ac, frequency: 0 25 hz (adjustable),firing angle control circuit and frequency control circuit to be provided built-in resistive load, terminals to be brought on ms panel with necessary symbols and circuits, pwm based step down dc chopper using mosfet/igbt kitpwm based step-down dc chopper (buck converter) power device : power mosfet / igbt based switching circuit input supply : 24 v dc to 110 v dc or derived from 230 v ac mains through rectifier unit output voltage :(0 to vin) variable dc output current : up to 5 a dc maximum with suitable load resistor (r load) pwm duty cycle control provided pwm generation and control circuit inbuilt gate driver circuit provided, single phase single pulse / sinusoidal pwm inverter using mosfet/igbt kittype : single phase pwm inverter trainer power device : mosfet / igbt based inverter circuit input supply : 12 24 v dc output voltage : 30 v rms ac output phase : single phase output frequency : 0 50 hz variable output power : 100 w single pulse pwm operation sinusoidal pwm (spwm) operation variable frequency control pwm generation and firing control circuit inbuilt gate driver circuit provided test points provided for waveform observation and analysis built-in resistive load provision, on / off control of lamp using solid state relay kittype : solid state relay (ssr) trainer kit control/input voltage : 12 v / 24 v dc or up to 30 v dc output load voltage : 230 v ac, single phase load control : on/off control of ac lamp load solid state relay based switching circuit opto-isolated input control built-in ac lamp load manual on/off switching arrangement led indication for input and output status, speed control of ac motor using vfd drive module with ac motortype : variable frequency drive (vfd) module input supply : 415 v ac, three phase, 50 hz output : three phase variable voltage and variable frequency ac output 1 hpthree phase squirrel cage induction motor415 v ac 50 hz &1440 rpm control technique : pwm / spwm based control frequency range : 0 50 hz variable digital display for frequency and operating parameters start / stop and forward / reverse control, acceleration and deceleration control facility powder coated ms control panel tabletop / floor mounted laboratory type setup clearly labelled circuit diagram and control switches proper insulated terminals and earthing arrangement, purchase - lab equipments for eee department electrical machines lab, three phase transformertype: three phase transformer, rating: 3 kva input voltage: 415 v ac, 3-phase, output voltage: 230 v ac, 3-phase frequency: 50 hz winding material: copper wound insulation class: class b or higher duty: continuous duty suitable for laboratory usebench/floor, dc stepper motor drive kit with stepper motorinput supply : 230 v ac, 50 hz stepper motor : permanent magnet / hybrid type with suitable driver circuits. motor operating voltage : 12 24 v dc variable speed control forward and reverse direction control full step and half step operation manual / automatic pulse generation facility built-in regulated dc power supply led indication for phase sequence and status test points provided for waveform observation start / stop control switches to be provided overload and short circuit protection to be provided mounted on compact powder coated cabinet with printed circuit diagram proper insulated terminals and interconnecting leads to be provided patch chords for interconnection., dc servo motor drive kit with servo motorinput supply : 230 v ac, 50 hz servo motor type : dc servo motor with feedback arrangement motor operating voltage : 12 24 v dc controller type : microcontroller based servo drive contr

CTN :45500330 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For supply of voltmeter - analog (panel meter) as per is 1248 (q3) , digital clamp meter , blower side fan belt assly , pannel rust remover , terminal plate motor centrifugal pump , motor vt pump 100 hp , terminal plate vt pump 50 or 80 hp , terminal plate centrifugal pump 20hp , transformer starter assly 30kw , copper parts long 63amp 440v , h.k mini auto protection , control panel assly single phase 3hp comp , control panel 20hp , tin coated fuse wire , amp meter 96x196 amp , volt meter 100x100 volt , amp meter 100x100 amp , amp meter 100x100 volt , oil starter 380 volt , rust remover , digital clamp meter 1000m2 , digital clamp meter , pvc tape roll , kachha rubber , kitkat grip parts 63amp , kitkat grip copper 100amp , kitkat grip 32amp , single phase motor protection , main switch 32amp , power capacitor isi 2kvar , ampmeter 4 30amp , voltmeter 4 500v , starter bentex 2 button , starter spares kit star 20 hp , electrical panel backlight , main switch 100amp 3 phase , main switch 63amp 3 phase , oil starter 3 phase 20hp 3 , exlents make grip kit kat 100amp , indicator lamp led bulb , power capacitor 6kvar , copper lugs 10 sq.mm , copper lugs 2.5sq.mm , bracket assly , amp meter 65x65 30amp , submersible cable 2.5 sqm , submersible cable 4.00 sqm , transformer oil , spare park kit mnx 110 , spare park kit for mnx 140 , electronic timer or 225 star delta , capasitor 120x150 mtr , digital meter double display , magnet coil 440v , capasitor 36 mtr , capasitor 72 mtr , round volt meter , round amp meter , eco panel dry stater 1.5 hp , eco panel dry stater 2hp , oil stater 5 hp dol , oil stater 7.5hp dol , single phase preventer , over load reley 13a 21a , waterproof rubber kacha , over load reley 9a 14a , alluminium wire 16 mm 4 core , copper wire 2.5 sqmm , mcb 32 amp , cutout 32 amp , cutout 63 amp , cutout 100 amp , 110mm pvc d joint , 90 mm pvc d joint , 75 mm pvc d joint , 65 mm pvc d joint , 110 mm threded pvc socket , 90 mm threded pvc socket , 75 mm threded pvc socket , 65 mm threded pvc socket , 110 mm threded cupling socket , 90 mm pvc cupling socket , 75 mm pvc cupling socket , 65 mm pvc cupling socket , 110 mm pvc elbow , 90 mm pcv elbow , 75 mm pvc elbow , 65 mm pvc elbow , 90 mm pvc pipe , 75 mm pvc pipe , 65 mm pvc pipe , 21 or 2 x1 or 2 , 3x1 or 2 nut , c.i. foot valve assly 100 , d.i. mechanical joint gaskit , d.i. mechanical joint 600mm , d.i. cast steet sluice , d.i. mechanical joint 150mm , d.i. flange , d.i. gaskit 150mm for joint , d.i. cast steel sluice , d.i. mechanical joint 450mm , d.i. mechanical joint 300 , d.i. socket tail piece 450mm , d.i gaskit 300mm for joint , cast steel long plug 50mm , cast steel long plug 65mm , cast steel long plug 80mm , mild steel flange , c.i non return valve 200mm flange , butter fly valve 200mm 8 , m.s flange 12mmx150mm , m.s flange 12mmx200mm , gun metal gate valve 50mm , gun metal gate valve 65mm , gun metal gate valve 80mm , g.i socket size 50mmx100mm , g.i pipe 1 1 or 4 x10 long , g.i socket size , pvc cloumn pipe 32mm digital clamp meter 0 to 2000 cm2 imported , blower side fan belt assly c-84 size fenew/anchor , pannel rust remover solution bottle for control panel use, terminal plate motor centrifugal pump 100 hp with 6 connection brass, terminal plate motor vt pump 100 hp with 6 connection brass, terminal plate vt pump 50/80 hp with brass connection, terminal plate centrifugal pump 20 to 30 hp crompton, //bid details 2 / 88

CTN :45404153 Due date: 09 Jun, 202609 Jun, 2026 NA
Tender For supply of equipment for electrical and electronics engineering department - supply of equipment forelectrical and electronics engineering departmen, loading rheostat 3 phase :specification :rating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided , loading rheostat 1 phase :specification :type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability , single phase resistive load :specification :type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability , three phase capacitor bank :specification :3-phase capacitor bank rating: 2 kvar voltage: 440 v ac frequency: 50 hz heavy duty self-healing capacitor units powder coated ms enclosure compact panel mounted/floor mounted construction proper ventilation arrangement to be provided capacitor duty contactor/switch to be provided fuse/mcb protection to be provided discharge resistors to be provided for safety proper earthing arrangement provided , plc tranier kit:specification :plc make :allen-bradley / delta electronics / siemens orequivalentdigital inputs : 8 20 nos.digital outputs : 6 12 nos. (led / relay type indication)communication port : rs232 / usb / ethernet (if available)programming method : ladder logic programmingtoggle switches for digital input simulationled indicators for output status indicationanalog potentiometers for analog input experimentsproximity sensor interface providedrelay output interface providedinput supply : 230 v ac, 50 hzbuilt-in regulated 24 v dc power supplyladder diagram programming software to be providedcompatible programming software license to be providedsuitable for basic plc programming and automationexperiments

CTN :45386599 Due date: 15 Jun, 202615 Jun, 2026 NA
Tender For purchase of lab equipments for eee dept - purchase of lab equipments for eee dept, single phase transformer.itemcode:b002 single phase transformer,rating: 1 kva, 50 hz, input: 230 v acoutput: 115 v ac,type: air-cooled, single-phase step-down transformer properly insulated input and output terminals brought out for safe operation)., acidity test kit itemcode:b005specifications:ethyl alcohol sodium carbonate solution universal indicator solution laboratory-grade test tubes droppers colour comparison chart for test result comparison chemicals supplied in labelled containers with safety instructions suitable for laboratory educational and testing applications, dc stepper motor drive kit with stepper motoritemcode:b010specifications:stepper motor : permanent magnet / hybrid type with suitable driver circuits. motor operating voltage : 12 24 v dc variable speed control forward and reverse direction control full step and half step operation manual / automatic pulse generation facility built-in regulated dc power supply led indication for phase sequence and status test points provided for waveform observation start / stop control switches to be provided overload and short circuit protection to be provided mounted on compact powder coated cabinet withprinted circuit diagram proper insulated terminals and interconnecting leads to be provided patch chords for interconnection, dc servo motor drive kit with servo motor itemcode:b011specifications:input supply : 230 v ac, 50 hz servo motor type : dc servo motor with feedback arrangement motor operating voltage : 12 24 v dc controller type : microcontroller based servo drive controller speed control : variable speed control to be provided position control : angular position control facility to be provided direction control : forward and reverse operation feedback device : encoder / potentiometer based feedback system built-in regulated dc power supply led indications for power and status test points to be provided for signal observation and analysis start / stop control switches provided overload and short circuit protection to be provided mounted on powder coated cabinet with printed circuit diagram proper insulated terminals and interconnecting leads to be provided, three phase resistive load itemcode:b013specifications:rating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided, single phase single pulse / sinusoidal pwm inverter using mosfet/igbt kit itemcode:b028specifications:type : single phase pwm inverter trainer power device : mosfet / igbt based inverter circuit input supply : 12 24 v dc output voltage : 30 v rms ac output phase : single phase output frequency : 0 50 hz variable output power : 100 w single pulse pwm operation sinusoidal pwm (spwm) operation variable frequency control pwm generation and firing control circuit inbuilt gate drivercircuit provided test points provided for waveform observation and analysis built-in resistive load provision, on / off control of lamp using solid state relay kit itemcode:b029specifications:type : solid state relay (ssr) trainer kit control/input voltage : 12 v / 24 v dc or up to 30 v dc output load voltage : 230 v ac, single phase load control : on/off control of ac lamp load solid state relay based switching circuit opto-isolated input control built-in ac lamp load manual on/off switching arrangement led indication for input and output status, speed control of ac motor using vfd drive module with ac motor itemcode:b030specifications:type : variable frequency drive (vfd) module input supply : 415 v ac, three phase, 50 hz o

CTN :45346460 Due date: 04 Jun, 202604 Jun, 2026 NA
Tender For supply of eee lab items dept use - three phase transformer rating: 3 kva input voltage: 415 v ac, 3-phase output voltage: 230 v ac, 3-phase frequency: 50 hz winding material: copper wound insulation class: class b or higher duty: continuous duty suitable for laboratory usebench/floor mounted suitable for laboratory operation all winding terminals shall be brought out to insulated terminals and enclosed within a protective outer cover for safe laboratory operation , dc stepper motor driver kit with stepper motorinput supply : 230 v ac, 50 hz stepper motor : permanent magnet / hybrid type with suitable driver circuits. motor operating voltage : 12 24 v dc variable speed control forward and reverse direction control full step and half step operation manual / automatic pulse generation facility built-in regulated dc power supply led indication for phase sequence and status test points provided for waveform observation start / stop control switches to be provided overload and short circuit protection to be provided mounted on compact powder coated cabinet with printed circuit diagram proper insulated terminals and interconnecting leads to be provided patch chords for interconnection. , dc servo motor driver kit with servo motorinput voltage 12 - 24v, dc, 5a, 10-60rpminput supply : 230 v ac, 50 hz servo motor type : dc servo motor with feedback arrangement motor operating voltage : 12 24 v dc controller type : microcontroller based servo drive controller speed control : variable speed control to be provided position control : angular position control facility to be provided direction control : forward and reverse operation feedback device : encoder / potentiometer based feedback system built-in regulated dc power supply led indications for power and status test points to be provided for signal observation and analysis start / stop control switches provided overload and short circuit protection to be provided mounted on powder coated cabinet with printed circuit diagram proper insulated terminals and interconnecting leads to be provided , three phase resistive loadrating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided , single phase induction motor with load arrangement 5hp ,230v, 1400 rpmsingle phase, 2hp,230v,1440 rpm with dol starter loading arrangement and electrical workbench mechanical rope with aluminum brake drum loading with adjustable wheels - 2 no s 0-50 kg spring balance - 2 no s electrical panel board with workbench -cupboard with door. panel board- with proper internal wiring& terminals insulated necessary symbols of motor and starter, fuse, supply indicators to be provided and printed on panel board -digital rpm indicator with proximity sensor to be provided -required number of digital ammeter , three phase synchronous motor with electrical workbench 3-phase synchronous motor with electrical workbench and loading arrangement , rating: 5 hp voltage: 440 v ac, 50 hz speed: 1500 rpm (synchronous speed), induction start using damper winding, suitable starter panel, dc supply (0 220 v dc adjustable (variable dc control) within the panel),and necessary workbench electrical panel board with workbench -cupboard with door. panel board- with proper internal wiring& terminals insulated necessary symbols of motor , starter, exciter, fuse, supply indicators to be provided and printed on panel board -digital rpm indicator with proximity sensor to be provided -required number of digital ammeters and voltmeters for motor to be provided on panel board. , synchronizing panelthree phase, 415v, 15a synchronizi

CTN :45351357 Due date: 04 Jun, 202604 Jun, 2026 NA
Tender For supply of lab equipments - purchase of lab equipments, acidity test kitspecifications:ethyl alcohol sodium carbonate solution universal indicator solution laboratory-grade test tubes droppers colour comparison chart for test result comparison chemicals supplied in labelled containers with safety instructions suitable for laboratory educational and testing applications, single phase resistive loadspecifications:type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability, three phase resistive load specifications:rating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided, three phase capacitor bank specifications: 3-phase capacitor bank rating: 2 kvar voltage: 440 v ac frequency: 50 hz heavy duty self-healing capacitor units powder coated ms enclosure compact panel mounted/floor mounted construction proper ventilation arrangement to be provided capacitor duty contactor/switch to be provided fuse/mcb protection to be provided discharge resistors to be provided for safety proper earthing arrangement provided, 3 phase auto transformer starter specifications: 3-phase variable autotransformer input: 415 v output: 0 470 v ac (continuous) current: 15 a copper wound, carbon brush type heavy duty toroidal/core construction mounted in powder coated ms/crca enclosure front panel mounted voltage control knob with scale indication proper insulated terminals provided floor/bench mounted type suitable for laboratory use input / output terminal arrangement provided mcb/fuse protection provided proper earthing terminal provided ventilation arrangement for heat dissipation, 3 floor lift interfacing model specifications: type: table-top lift model floors: 3 levels structure: transparent acrylic / ms frame cabin: moving lift car with guide rails drive: dc geared motor / stepper motor motion: up/down movement, floor indication leds (1, 2, 3) direction indicators (up/down), start & stop atevery stage, over load limit control three-floor lift operation plc interfacing and programming floor selection logic automatic stopping at floors direction indication system educational demonstration of elevator automation, mcb elcb trainer kit specifications: 1 phase/3 phase, 2/3/4 pole, 3a-16a single pole mcb 2-5amps two pole elcb 30ma lamp load single phase 5amps panel enclosure and terminal outlets, signal generator specifications: frequency range: 0.1 hz to 5 mhz. display: 4 to 6 digit led display output waveforms: sine, triangle, square, pulse, ramp. amplitude: 0 20 vp-p. rise time: 100 ns. distortion, dso specifications: bandwidth: 50 - 100 mhz. sampling rate: 1gs/s. channels: 2 (minimum) power supply: 100v 240v ac, 50-60 hz automatic measurement: vpp, vavg,rms, frequency, period, vmax, vmin, rise time, fall time, + width, - width, +duty, - duty etc., horizontal scale: 5 ns/div 50 s/div or equivalent vertical resolution: 8 bits (2 channels simultaneously) vertical sensitivity: 1 mv/div 10 v/div (at input) waveform math: +, -, x , , invert, fft etc., waveform storage: 16 waveforms or equivalent communication interface: usb host, usb interface. 7-inch color display or equivalent input impedance - 1 m 2%, // 20 pf 2 passive probes (1x/10x), pwm based
 Loading, Please wait...

Connect us via What's Up