Web Analytics Made Easy - StatCounter

Load Tap Changer Tenders

Get complete information related to latest Load Tap Changer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Load Tap Changer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Load Tap Changer Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45488637 Due date: 23 Jun, 202623 Jun, 2026 NA
Tender For purchase of 3 phase auto transformer starter lab equipment for eee department

CTN :45476989 Due date: 18 Jun, 202618 Jun, 2026 NA
Tender For procurement and installation of eee lab equipments - procurement and installation of eee lab equipments, dc series motor with starting and loading arrangement with electrical work bench motor rating: 5 hp , 220 v , 1500 rpm, loading arrangement : mechanical rope with aluminum loading with adjustable wheels - 2 no s 0-50 kg spring balance - 2 no s workbench: with back side lock 1. 2 point starter 2. ammeter ( 0 - 30a) dc 3. voltmeter ( 0- 300v) dc 4. rheostat - 1 no., single phase transformer step dwon, single phase, 2kva , 230/115 v , 4a / 8a, 3 phase transformer step down three phase, 2kva, 440/220v., transformer oil bdv test kit single phase, 230v, output voltage 60kv with timer, acidity test kit single phase, ac 230v,50hz, astm d974, rating scale, ,color chart, required, test tunes & solutions, three phase auto transformer three phase variac, 415 / (0-470)v, 15a, linear variable differential transformer measurement trainer input voltage : 230 v ac / 50 hz lcd display, digital voltmeterlvdt stroke length : 25mm potentiometer includedoperating temperature :10 c to 50 c, dso bandwidth: 50 mhz channels: 2 (dual trace)sampling rate: 1 gsa/s time base & voltage controls: variable display: color lcdprobes: 2 nos supplied interface: usb

CTN :45479514 Due date: 25 Jun, 202625 Jun, 2026 NA
Tender For distribution transformer of rating 250 kva, 11kv/415v-240v, 3-phase, 50hz, outdoor type, plinth mounted, the type of tap changer: off-load tap changer for variation of hv voltage from +5% to -10% in steps of 2.5%, energy efficiency level 3 or better, oil immersed, non-sealed type (transformer tank body and cover are bolted), copper wound, primary winding in delta and secondary winding in star (vector symbol- dyn11), onan cooled transformer, conforming to is 1180 (part 1):2014 with amendment nos. 1,2,3,4 or latest, and supplied with all standard fittings mentioned in clause 20.1 of is 1180 (part 1) latest withcondition that drain-cum-sampling valve will be applicable for all capacity of transformers. oil temperature indicator & winding temperature indicators will be provided as per clause 20.2 f) of is 1180 (part 1). terminal arrangement: the transformers shall be fitted on high voltage and low voltage sides with outdoor type bushings of appropriate voltage and current ratings. the high voltage bushings (3 nos.) shall conform to is/iec 60137. the low voltage bushings (4 nos.) shall conform to is 7421. suitable cable-end box along with cable entry hole glands is to be provided at l.t. side. following has to be submitted by supplier along with supply of material: (i) type test report of transformer having same rating, make (& model if any) and design from nabl accredited lab as per is: 1180 (part 1) latest. (ii) routine test certificates as per is: 1180 (part 1) latest. (iii) special test certificates as per clause 21.4 sl. no. (a), (c), (d) & (e) of is: 1180 (part 1) latest. detailed specification attached as annexure a. [ warranty period: 30 months after the date of delivery ]]

CTN :45470987 Due date: 29 Jun, 202629 Jun, 2026 NA
Tender For supply & testing of 500 kva, 11kv/750v, 3-phase, 50 hz. outdoor type power transformer conforming to 15 2026 (part 1): 2011 (reaffirmed 2021), plinth mounted, copper wound, mineral oil immersed with freely breathing system (also called conservator system) as per clause 8.2 (a) of is 2026 (part 1), primary winding in delta and secondary winding in star (vector symbol-dyn11), onan cooled transformer, minimum short circuit impedance of 5% as per is 2026 (part 5), with all fittings specified in annexure a to this description, terminal arrangement: the transformers shall be fitted on high voltage and low voltage sides with outdoor type bushings of appropriate voltage and current ratings. the high voltage bushings (3 nos.) shall confirm to is/iec 60137. the low voltage bushings (4) nos.) shall conform to 15.7421. suitable cable-end box is to be provided as follows: a) for outdoor type: l.t. side tap changer: on-load tap changerfor variation of hv voltage from -+5% to -5% in steps of 1.25% make- andrew yule/aeg/crompton greaves/kirloskar electric co./abb/siemens/schneider or similar. [ warranty period: 30 months after the date of delivery ] ]

Central Government And Public Sector

CTN :45192273 Due date: 15 Jun, 202615 Jun, 2026 NA
Tender For corrigendum : providing services overhauling and testing of on-load tap changer (oltc) make ctr and high voltage circuit breaker on-site at hbl plant sugauli

corporations/Associations/Others

CTN :45440937 Due date: 15 Jun, 202615 Jun, 2026 27.66 Lacs
Tender For providing & constructing np3 pipe line for under ground draiange line and open drain to convert / fixing d.i , ms pipe line & monoset sub. pump 3phase,auto transformer starter , pvc insulated round submersible cable for water supply various areas @ tharad nagarpalika . dist : vav-tharadgrant: - sjmmsvy-udp-88- 2025-26

CTN :45449765 Due date: 15 Jun, 202615 Jun, 2026 NA
Tender For supply of bearing ball , pinion starter , bearing ball 30 mm , variac auto transformer , bearing 32307 , v belt a68 , oil seal , avr lci

CTN :45275851 Due date: 10 Jun, 202610 Jun, 2026 80.0 Thousand
Tender For corrigendum : providing, installation and testing of 60 hp capacity fully automatic auto transformer starter and allied works for lis yechinambal.

CTN :45418480 Due date: 12 Jun, 202612 Jun, 2026 NA
Tender For purchase of lab equipment for eee - acidity test kit, synchronizing panel, 3 phase auto transformer starter

CTN :45048307 Due date: 30 Jun, 202630 Jun, 2026 NA
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp
 Loading, Please wait...

Connect us via What's Up