Get complete information related to latest Louver Shutter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Louver Shutter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Louver Shutter Tenders.
Tender For corrigendum : certain repair to b/r and e/m items in zone c under ge roorkee - demolition of brickwork or stone boulder masonary built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed., m&l for brick work, with class b brick straight or curved on plan to any radius built in cement mortar (1:6) as in raising of manholes and septic tanks complete all as specified and directed, taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed, m&l for rendering 15 mm thick on fair faces of brick surfaces or concrete surfaces and finished surfaces even & smooth in cm 1:4 complete including mixing water proofing compound complete all as specified and directed, supply only water proofing compound complete all as specified and directed., m&l for rendering 15 mm thick on other than fair faces of brick surfaces or concrete surfaces and finished surfaces even & smooth in cm 1:6 complete all as specified and directed, m&l for preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of primer complete all as specified and directed, m&l for preparing newly plastered surface of wall and applying two coats of oil bound distemper complete all as specified and directed, m&l for complete removal of existing treatment from walls (any number of layers) by scrapping with steel scrappers or any other means, including filling depressions of scrapped surfaces and applying two coats of oil bound distemper, over and including a coat of 1 mm thick wall care putty with preparation of plastered surfaces complete all as specified and directed., m&l for preparation of old decorated wall surfaces by complete removal of existing treatment on walls including cornices by broming down with steel brush, scrapping down smoke soot, moulds moss and efflorescent salts and trading oil and grease spots and applying two coat of cement base paint inluding one mm thick cement base putty complete all as specified and directed., m&l for preparation of old decorated wall surfaces by complete removal of existing treatment on walls including cornices by broming down with steel brush, scrapping down smoke soot, moulds moss and efflorescent salts and trading oil and grease spots and applying two coats of 100% premium acrylic emulsion paint having voc less than 50 gm/litre and uv resistance as per is 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces inluding one mm thick cement base putty all as specified and as directed. (note: painting of overhead tank min height 18 to 25 meter), m&l in repair for built in steel cup board with pressed steel frame of size 75 mmx45mmx1.25 mm thick with pressed steel shutter 1mm thick godrej pattern fixed to masonry wall by hold fast made out of 25x3 mm flat iron including ms hanging rod of 10 mm dia with bracket fixed on inner side of one leaf of shutter and on other leaf provision of ms peg set of 3 pegs including spray including locking arrangement spray painting with two coats of synthetic enamel paint over one coat of red oxide primer with two coats of synthetic enamel paint over one coat of red oxide primer all around on steel surface of frame & shutter and making good disturbed portion in cm (1:3) or pcc (1:2:4) type b-0 complete all as specified and directed., s&f in repair 110 mm dia pvc (swr) bends any radius with oval access door complete all as specified and directed, s&f in repair 75 mm dia pvc (swr) bends with access door any radius complete all as specified and directed, s&f in repair 75 mm dia pvc (swr) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed to w
Tender For supply of and f of gi box with modular plate and cover including p and f modular 3 pin 5 or 6 amps socket outlet and 5 or 6 amps switch , s and f of gi box with modular plate and cover including p and f modular 6 pin 5 or 6 and 15 or 16 amps socket outlet and 15 or 16 amps switch , s and f of 5 or 6 amp modular switch , s and f of 3 pin 5 or 6 amp modular socket outlet , s and f of 15 or 16 amp modular switch , s and f of 6 pin 15 or 16 amp modular socket outlet , s and f of rj 45 computer socket cat 6 , s and f of 4 module or 125mm x 75mm size modules gi box with base and cover plate , s and f of 8 module or 125mm x 125mm size modules gi box with base and cover plate , s and f of 3 module or 100mm x 75mm size modules gi box with base and cover plate , s and f of 1 or 2 module or 75mm x 75mm size modules gi box with base and cover plate , s and d of 1 run of utp 4 pair cat 6 lan cable , s and d of 2 run of utp 4 pair cat 6 lan cable , s and d of 3 run of utp 4 pair cat 6 lan cable , s and d of 4 run of utp 4 pair cat 6 lan cable , s and d of 6 run of utp 4 pair cat 6 lan cable , s and d of 8 run of utp 4 pair cat 6 lan cable , s and d of 16 run of utp 4 pair cat 6 lan cable , s and d of 20 run of utp 4 pair cat 6 lan cable , s and m end termination with rj45 plug , s and f modular blanking plate , s and f of 450mm heavy duty exhaust fan along with louvershutters , s and f of 225mm heavy duty exhaust fan along with louvershutters , sitc of recess mounting type 36w led cool white luminaire of 2 ft x 2 ft size modular fitting , s and installation of 22 watt led batten, 4 feet light fitting , s and f two module stepped type electronic fan regulator on the existing modular plate switch box , itc of ceiling fan including wiring the down rod , sitc of 1 phase 400 mm sweep, high speed wall mounted bldc motor fan , sitc of round led down lighter recess mounting fitting of 15w, 230 volts, 50 hz , s and f of control contactor for emergency lighting of rating 4 amp, having coil voltage 230 volts, 50 hz, with 2no plus 2nc contacts , s and l of 75mm x 38 mm size one compartment gi raceway , s and l of coupler for 75mm x 38 mm size gi raceway , s and f of jb 150mm x 150mm x 50m mm with 50_70 mm size gi height adjustable junction box with base and cover plate , supplying and installing 300mmx50mmx1. 6mm thick perforated prepainted ms cable tray , supplying and installing 300mmx50mmx1. 6mm thick perforated prepainted ms cable tray bend , supplying and installing 300mmx50mmx1. 6mm thick perforated prepainted ms cable tray tee , supplying and installing 300mmx50mmx1. 6mm thick perforated prepainted ms cable tray cross member , s and f of 8 way 4plus24 ways double door horizontal type tpn sheet steel mcb db_415v , s and f of 8 way double door vertical type 415v tpn sheet steel mcb db suitable for mounting mccb as incomer 8 plus 8 plus 8 ways for outgoings , s and f of 8 way double door spn sheet steel mcb db_240v , p and f of 100 a 4 pole mccb , s and f of sp 5 amps to 32 amps rating 240 v c curve mcb , s and f of spn 5 amps to 32 amps rating 240 v c curve mcb , s and f of tp 5 amps to 32 amps rating 415 v c curve mcb , s and f of tpn 5 amps to 32 amps rating 415 v c curve mcb , s and f single pole blanking plate in the existing mcb db , p and f 6 swg dia gi wire along with existing surface or recessed conduit or submain wiring or cable , p and f 4 mm dia cu bare wire along with existing surface or recessed conduit or submain wiring or cable , supplying of 4 core 35 sq. mm aluminium conductor pvc insulated and pvc sheathed or xlpe armoured cable , //bid details2 / 77supplying of 3. 5 core 95 sq. mm aluminium conductor pvc insulated and pvc sheathed or xlpe armoured cable , laying and fixing of one number upto 35 sq. mm size cable on wall surface , laying and fixing of one number above 35 sq. mm and upto 95 sq. mm size cable on wall surface , laying and fixing of one number upto 35 sq. mm size cable on cable tray , laying and fixing of one numbe
Tender For supply of exhaust fan gravity louvershutter suitable for 300 mm size wall mounted exhaust fan , exhaust fan gravity louvershutter suitable for 450 mm size wall mounted exhaust fan , exhaust fan gravity louver (shutter) suitable for 230 mm size wall mounted exhaust fan