Tender For corrigendum : tender for supply of tree branch trimming along the ht overheadline pole erection and laying of lt cable in narwapahar - tree branch trimming along 6.6kv overheadlines within the plant & township boundary area of narwapahar , laying of one no. of pvc insulated & pvc sheathed / xlpe power cable of 1.1kv grade of following size direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. upto 35sqmm. (16mm2 25 mm2 &35 mm2) , laying of one no. of pvc insulated & pvc sheathed / xlpe power cable of 1.1kv grade of following size direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. above 95 mm2 & upto 185 mm2. (120 mm2.) , supply & making end termination with brass compression gland & al. lugs of pvc insulated & xlpe al. conductor cable of 1.1kv grade for size 2 x 16 sqmm , supply & making end termination with brass compression gland & al. lugs of pvc insulated & xlpe al. conductor cable of 1.1kv grade for size 3.5 x 25 sqmm , supply & making end termination with brass compression gland & al. lugs of pvc insulated & xlpe al. conductor cable of 1.1kv grade for size 3.5 x 120 sqmm , supply & making end termination with brass compression gland & al. lugs of pvc insulated & xlpe al. conductor cable of 1.1kv grade for size 3.5 x 35 sqmm , supply & erection of octagonal pole 9 mtrs long in cement concrete foundation including excavation and refilling and secured with holding clamps , bolts and nuts as required , supply & embeding following dia gi pipe 32mm dia (medium class) in pole collar / founding (during casing) for cable entry including beding in the pole to the required shape complete as required , installation of gi wire 8 swg for ground wire , installation of complete stay set incl. supply of necessary fixing materials , installation of gi wire 7/10 swg for stay set in existing o/h line , installation of insulating sleeves in ryb phases of o/h line
Tender For work of substation earthing, overhauling of power tf installation of double-circuit underground cables, and construction/strengthening of 11k ht/ltlines within the industrial area(phase-2) under the jurisdiction of edd-mughalsarai bp 2026-27.
Tender For towards extension of 6.6kv(feeder no.50)grade overheadlines 5 pit substation to works(asbnc),loyabad colliery to provide 6.6kv power to workshop for testing of motors,breakers and starters after repairing used for different colliery under sijua area
Tender For : for the work of replacemnet of 33 kv poles / conductor , guarding of lines ,interlinkng of 33 kv lines etc. under 33 kv vertical, bareilly for system strengthening for providing uninterrupted 24*7 power supply under the head of (b.p. 2026-2027).
Tender For purchase of equipments for materials testing lab for civil department - spring testing machineload & displacement sensing load cell capacity: 0 10 kn accuracy: 1% fs (better if 0.5%fs) displacement sensor lvdt / digital encoder accuracy: 0.5 mmmachine design frame: rigid steel frame with crosshead movement type: mechanical screw with hand wheel (simple & robust) or electromechanical actuator (for smoother, controlled motion) crosshead travel: ~150 200 mm safety guards: transparent shields around moving partsfixtures & accessoriesspring testing compression plates (ground & parallel) tension hooks / eyelets for extension springs set of spacers / adapters for small springs tensile testing standard tensile grips wedge or screw type calibration certificate for load cell standards complianceensure compliance with basic material test standards such as: astm e4 / iso 7500-1 calibration of force measurement astm e8 / iso 6892 tensile performance & accuracy load accuracy: 1% fs displacement accuracy: 0.5% repeatability: 0.5%, rockwell cum brinell hardness testing machine min initial test force :10kgf, total test force range : 60kgf,100kgf,150 kgf, max. height of specimen :215 mmmin distance from indenter center tomachine wall :132 mm accessories : steel ballpreferred indentor 1/16" preferred steel ball: 1/16"and with all standard accessories to run the machine, direct shear machinestandard compliance:the equipment shall confirm to bureau of indian standards is 2720 (part 13) and equivalent astm international astm d3080.technical specifications:shear box size: 60 mm 60 mm 25 mm specimen size (complete with grid plates, porous stones, and specimen cutter).normal load capacity:minimum 5 kn with loading yoke and calibrated loading hanger set.shear load capacity:minimum 2.5 kn or 5 kn with calibrated proving ring (with calibration certificate).rate of strain (shear displacement):variable speed drive with controlled displacement ranging from 0.01 mm/min to 1.25 mm/min (motorised model preferred for uniform rate control).displacement measurement:horizontal displacement dial gauge: 0.01 mm least countvertical displacement dial gauge: 0.002 mm or 0.01 mm least countloading frame:rigid, heavy-duty loading frame with corrosion-resistant finish.drive system:motorised with single phase 220 230 v, 50 hz power supply.accessories (to be supplied complete):shear box assembly, proving ring with calibration chart, two dial gaugesloading weights and hanger, porous stones (2 nos.), specimen cutter, tool kit, flow table test apparatusdimensions and specifications as per is 9103, table top made from flat metal plate, minimm thickness 1.5 mm. table top size: 700 mm 700 mm, with flatness tolerance of 1.5 mm. table top marked with: scribed cross at centre, lines parallel to table edges and central circle of 200 mm diameter underside of table top reinforced to prevent distortion. total mass of table top: 16 1 kg. table top, base frame front and upper stops provided as per is 9103. lower front edge fitted with two rigid stops to transfer load directly to base frame. base frame designed to transfer impact load directly to supporting surface, minimizing bounce. stop watch digital - 2 nos scale 1 mtr 2 nos mounting wooden platform 300 mm height amc for 3 years inclusive.
Tender For purchase of electronics and communication engineering practices (equipment) - equipments for electronics and communication engineering practices:, 8051 micro controller kit operating voltage: +5 v dc. flash memory: 4 kb (at89c51) / 8 kb (at89s52). ram: 128 bytes internal ram. 16 2 alphanumeric lcd display. push buttons / tactile switches. dip switches for digital input. inbuilt adc interface: ldr, potentiometer. inbuilt dac interface. inbuilt stepper motor driver with stepper motor. inbuilt dc motor driver with dc motor. 1 4 led array, 1 4 keypad, 1 relay. 1 buzzer, 16 2 lcd display, 1 pwm driver. 1 hardware interrupt key, inbuilt rtc. inbuilt eeprom and uart module. 4 7-segment display. supports both assembly and c language programming. pc interfaceable., embedded trainer kit (using lpc2148) cpu -lpc2148, core -16/32 bit arm7tdmi-s speed -max 60 mhz, flash -512kb, ram (on-chip) 40kb, 46 general purpose i/opins, usb2.0 one 10bit a/d converterwith 14 analog inputs, one 10bit d/a converter, six pwm &watchdog two uarts (16c550), two i2c (400kb/s), two spi eight bit digital output, eight bit digital input,16x2 characters lcd and 4x4 matrixkeypad one potentiometer for giving analog input, relay & buzzer interface i2c devices: rtc, eeprom and seven segment display, on board stepper motordriver lm35 temperature sensor, one rs 232 lines are terminated at 9 pin d type connector and usb interface board has inbuilt power supply and mounted in sturdy cabinet accessories usb cable with utility software to download programs from pc to target board power cord, user manual, ask modulation and demodulation kit message signal1:8-bit variable data,amplitude 5v. message signal 2:debounced data, amplitude low (0) and high (5 v). message signal 3:fixed data 25 khz, 12.5 khz, 6.25 khz, 3.12 khz, amplitude 5 v. carrier signal: sine wave, frequency 200 khz, amplitude 5 v. modulator type: switching modulator using analog switch / transistor switching ic. demodulator: envelope detector and lpf. comparator: lm311 based. supply voltage (board): +12 v, +5 v dc. supply current: 100 ma minimum. input voltage: 230 v ac, 50 hz. interface connectors: 2 mm banana socket., dth trainer kitpower supply: 200 v to 240 v ac, 50 hz.dish antenna: 1.5 ft aluminium steerable dish antenna.lnb (low noise block down converter):input frequency: ku-band. output frequency: 950 mhz to 1450 mhz. conversion gain: 65 db. noise temperature: 35 k (max).set-top box receiver in trainer form: if frequency: 70 mhz. video bandwidth: 50 hz to 5 mhz. video output level: 1 vpp at 75 load. video polarity: normal/inverted, switch selectable. audio subcarrier frequency: tunable from 5.0 mhz to 8.0 mhz. remote control provided. hdmi cable: 10 m.controls: channel selection. volume control.fault simulation: five built-in simulated faults for troubleshooting experiments. if signal disconnected. video output fault. audio mute fault. tuner misalignment. rf output interruption.pcb size: 15" 12" with multicolour section-wise block diagram.standard accessories: 1.5 ft dish antenna. lnb. trainer pcb. dish connecting wire. audio-video cable. user manual. acrylic cover. hardware materials for assembly of dish antenna.additional features: dth subscription connection with doordarshanfree channels. free-to-air channel demonstration.
Tender For operation and maintenance of 33 11 0440 kv sub station overhead transmission lines within the mining lease and acquired land area and power supply systems to various installations therein at kasnau matasukh lignite mines district nagaur
Tender For operation &amp maintenance of 33/11/0.440 kv sub-station, overhead transmission lines within the mining lease & acquired land area and power supply systems to various installations thereinat kasnau-matasukh lignite mines, district nagaur
Tender For under the business plan 2026&27, under the business plan 2026&27, to increase the capacity of the distribution transformer under the sub-centre jaila in the jurisdiction of budhana, at various places to separate the 33 kv line of the sub-centre budhana town from the power lines of other sub-centres. work related to laying of x-l-p cable] work related to strengthening of various ul-t-lines in the area of power sub-station mindakali] habibpur] luhsana] shahdabbar and shahpur and providing trolley changer at power sub-station jaila.
Tender For stage/rate contract for supply of key material/equipments required for operation/maintenance of 33kv lines and 33/11-6.6 kv receiving stations valid for the financial year 2026-27 or till finalization of next stage contract - power transformers, supply of transformer oil as per is: 335-1993 with latest amendments thereof, supply of buchhloz relay for 33/11-6.6 -6.6 kv transformer protection (10mva / 6.3 mva/ 5mva) as per is 3637:1966, supply of winding temperature indicator (wti) for 33/11-6.6 kv power transformer (10 mva / 6.3/ 5 mva ) as per relevant is 5561 standard., supply of oil temperature indicator (oti) for 33/11-6.6 kv for power transformer (10 mva / 6.3/ 5 mva )as per relevant is 5561 standard., supply of cork sheet 6 mm as per relevant is 5561 standard., supply of old sarees/dhoti cloth, supply of gaskets suitable for power transfomers, 33kv ct&pt, supply of 33/11-6.6kv power transformer (10/6.3/5 mva)bush rods with copper washers as per relevant is 3347 standard., hv side, lv side, supply of 33/11-6.6kv power transformer (10/6.3/5 mva)bushes as per relevant is 3347 standard., hv side, lv side, supply of 11 kv spout bushes (indoor type) conforming to relevant standards ammended up to date, supply of mechanical plunger (conforming to relevant standards ammended up to date ) for, 11 kv breakers (both incoming & outgoing), 33 kv vcbs both indoor & outdoor type, supply of 11 kv partition insulators/ bushes with inbuilt studs of required size conforming to relevant standards ammended up to date as per directions of site engineer, supply of dc connector for 11 kv panels conforming to relevant standards ammended up to date, supply of breather conforming to latest is 3202 (ammended up to date) for 10mva/ 6.3mva/ 5/ 3.15 mva., supply of silica gel as per is :3202, supply of o-ring oil sealing of sizes for power transformer bushes (hv/lv) as per is 3202., supply of galvanised iron angle/channel/flat per is :2062 grade "a" of sorts and sizes, g i channel 100x50x50x6 mm, g i channel 75x40x40x6 mm, g.i angle iron 65x65x6 mm, g.i angle iron 50x50x6 mm, g.i flat iron 40x6/ 50x6 mm, supply of arching horns (set of three pieces) for power transformer, supply of g.i bolt full thread of sorts and sizes with washers and nuts of different sorts and sizes, supply of 33kv current transformer (3-core) of reputed make,outdoor oil cooled, single phase (comprising of 3 no.) (as per is 2705 -1992 having ratio of is (is 2165, is 2705(i-iv), is 2099, is 5621, is 2071, is 335, is 13947(part i), iec 185,iec 270, iec 44(4), iec 171, iec 60, iec 8263, iec 815, indian electricity rules 2010), 400-200/5-5-5 a, 300-150/5-5-5 a, 250-125/5-5-5 a, 200-100/5-5-5 a, supply of 11 kv c.t.(2-core/3-core) of reputed make suitable for 11kv vcb panels (comprising of 3 no.) as per is (is 2165, is 2705(i-iv), is 2099, is 5621, is 2071, is 335, is 13947(part i), iec 185,iec 270, iec 44(4), iec 171, iec 60, iec 8263, iec 815, indian electricity rules 2003) having ratio:-, 800-400-200/5-5a, 750-375-187.5/5-5a, 600-300-150/5-5a, 400-200-100/5-5a, 200-100/5-5a, 150-75/5-5a, 100-50/5-5a, 50-25/ 5-5a, 33kv and 11kv outdoor type potential transformer, supply of 33kv potential transformer (comprising of 3 no.) of ratio 33kv/ 3 / 110v / 3 ,single phase,outdoor oil cooled, dead tank type pt as per is:3156 -1992, supply of 11kv potential transformer 11kv/ 3 / 110v / 3 three phase box type (combo unit) as per is :3156-1992, supply of 11kv potential transformer (comprising of 3 no.) 11kv/ 3 / 110v / 3 single phase seperate type as per is :3156-1992, 11kv and 33kv vcbs, supply of master trip relay 24-50 v rel 615 abb ied suitable for 11kv vcb switch gear panels (compitable for electric feild, pascal, scheinder, abb, essan l&t or any other equilant make), supply of digital protection relay adr 141c, rel 615 /abb ied,model no. er113 2 o/c + 1 e/f with high trip (mit113), auxiliary voltage = 0-36 volt conforming to iso 9001:2008 standards (compitable for electric fe