Web Analytics Made Easy - StatCounter

Lt Pole Tenders

Get complete information related to latest Lt Pole Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lt Pole Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lt Pole Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45488694 Due date: 18 Jun, 202618 Jun, 2026 9.88 Lacs
Tender For shifting of ht/lt poles and lines exists in the alignment of plots in various sectors u/e karnal. (including one year free maintenance and defect liability period free of cost) (rates taken in dnit exclusive gst).

Central Government/Public Sector

CTN :45491043 Due date: 30 Jun, 202630 Jun, 2026 43.42 Lacs
Tender For special repair / replacement of external electrification, lt panels, lt poles, street lights, flood lights and connected work at civ lines nagpur and provision of bollard lights, post top latern and building seurity lights at mdc kamptee under ge kamptee.

Central Government/Public Sector

CTN :45475154 Due date: 30 Jun, 202630 Jun, 2026 30.00 Lacs
Tender For repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and getting out in an

Central Government/Public Sector

CTN :45481992 Due date: 23 Jun, 202623 Jun, 2026 45.00 Lacs
Tender For repair and maintenance of external lt power distribution networks including replacement of ug cables, pole painting, mccbs, lt panels and other associated components at altinho, bambolim and other locations within the aor of age e/m under ge panaji

State Government

CTN :45484048 Due date: 24 Jun, 202624 Jun, 2026 NA
Tender For providing of custom bid for services - for the work undergrounding of overhead/ht/lt lines and shifting of lt poles on turn key basis for sadar bazar under 11 kv ghantaghar feeder supplied from 33/11 kv substation gandhi park under the jurisdiction of eudc firoza..

CTN :45344777 Due date: 11 Jun, 202611 Jun, 2026 10.00 Lacs
Tender For corrigendum : :work of replacment / strengthening of lt cbale & replacement of damaged lt pole in the different area of under 11 kv & lt vertical, bareilly for strengthening of electrification system under 11 kv & lt vertical, bareilly under business plan-2026-27 bareilly

State Government

CTN :45441269 Due date: 17 Jun, 202617 Jun, 2026 13.71 Lacs
Tender For stringing of 1.1 kv 3ph lt abc 70sqmm 6730 meter sph lt abc 25sqmm 5761 meter and erecting 107 no. lt poles.

State Government

CTN :45428792 Due date: 16 Jun, 202616 Jun, 2026 NA
Tender For tender for ht/lt pole upgradation work at various location

State Government

CTN :45402092 Due date: 08 Jun, 202608 Jun, 2026 8.20 Lacs
Tender For shifting of lt poles, ht poles and transformers from main gates of plots in various sectors under hsvp electrical sub division no-1 faridabad.(idc) - shifting of lt poles, ht poles and transformers from main gates of plots in various sectors under hsvp electrical sub division no-1 faridabad.(idc) a/cost rs.8.21 lacs e/money rs.16420.00 time limit : 8 months

Central Government/Public Sector

CTN :45417883 Due date: 17 Jun, 202617 Jun, 2026 38.00 Lacs
Tender For repair/ replacement of earthing , lt panel , mccbs, bus bar, changeover, painting of pole and other e/m miscellaneous work at bb cantt, srinagar
 Loading, Please wait...

Connect us via What's Up