Get complete information related to latest Lt Breaker Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lt Breaker Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lt Breaker Repair Tenders.
Tender For supply of isolator 200 amps_ 3_3kv on_off_ht_100 , isolator fixed contact set_ht_100_1 , isolator moving contact set_ht_100_2 , vaccum contactor 400 amps_ 3_3kv_ht_200 , vaccum contactor closing coil 110v dc_ht_203 , vaccum contactor holding coil 110v dc_ht_204 , ht control fuse 3_3kv_ 2 amps_ht400 , copper terminal bar_ht701 , e_l_ unit complete without transformer_ht_800 , 3 pole magnetic o_l relay_ht900 , ct operated thermal overload relay with kit 4 to 6a or 405 to 7_5a_ht900b , hrc fuse base and carrier for control_ht_1200 , hrc fuse link 4 amp for control_ht_1201 , push button with element for start_ stop_ test and reset_ht_1300 , lamp holder with lamp for starter_ht_1400 , power hrc fuse_ht_1500 , brass cable gland complete with ci clamps_ stud_ht1600 , isolator limit switch_ht_1700 , single phase preventor _cop_20_ pfr make_ht_2001 , under voltage relay_ht_2000 , pilot relay 12v dc_ht_2200 , timer pneumatic 10 to 180 sec_ or _1 to 3_ sec_ht2004 , bottol for vacuum contactor 3_3kv_6_6kv_ 400 amps_ht_202 , vaccum contactor rectifier_bridge_ht_201 , static type idmtl over current and short circuit relay_ht 900a ) /bid number : gem/2026/b/7359256 * /dated: 16-03-2026 & & / bid document 1 / 28
Tender For corrigendum : supply of emergency push button switch (q3) , led based indicating lamp for panel cut outs (q2) , auxiliary switch for vacuum contactor part no ht205 or equivalent , potential transformer 50va part no ht206a or equivalent , resin cast potential transformer 750 va part no ht300a or equivalent , resin cast moulded cbct suitable for earth leakage relay part no ht800 make nflp dol starter 6. 6kv, inner dia 65 mm, circular shape, part no ht500a or equivalent , current transformer resin cast moulded part no ht600a or equivalent , current transformer resin cast moulded part no ht650a or equivalent , voltmeter72mm2 part no ht1100a or equivalent , hrc fuse base and carrier f control, part no ht1200 or equivalent , hrc fuse link 10a for control 110v ac, part no ht1201 or equivalent , isolator limit switch1 no plus 1 nc, thermal current 16a, rated insulation voltage 600v, part no ht1700 or equivalent , copper busbar 400 amps,6. 6 kv set of three, part no ht101a or equivalent , auxiliary contactor 3no plus 1nc, 110v ac, rated insulation voltage 600v, as per is iec 60947, part no ht208 or equivalent
Tender For supply of overhauling & maintenance of cp transformer rectifier units , ac amp. meter, for detailed description refer price breakup sheet , ac volt meter, for detailed description refer price breakup sheet , dc volt meter, for detailed description refer price breakup sheet, dc amp. meter, for detailed description refer price breakup sheet, voltmeter ( psp meter ), for detailed description refer price breakup sheet, main rectifier diodes, iav 150 amp, piv - 1200 v , type- 150 lf 120 , "lightning arrestor( la) both input and output side, rms voltage rating - 500v ,rms current rating - 1.5 ka, type- lt 0.5 oe eqv", thyrister module (scrm) consisting two antiparrallel thyrister, for detailed description refer price breakup sheet, auxiliary transformer for control circuit power supply, for detailed description refer price breakup sheet, filter capacitor bank in dc output , 2500 micro farad , 150v x 6 electrolytic capacitors, relay for providing remote contacts for mcb tripped & ac supply fail faults , coil - 240 v ac coil resistance 10 k contacts 2no+2nc , 8 pin plug in type, relay for providing remote contacts for oil tank or instrument , chamber high temp. fault. coil - 240 v ac coil resistance 10 k contacts 3no+3nc , 11 pin plug in type, thermostate with adjustable temp. setting with nc contacts ( 30 to 110 setting ), indicator lamp , housed in 22.5 mm dia, 240 v, led type red colour, auto or manual mode selector rotary type, 4 pole , 2 way ,63 amps, 240 v, ac type srpm 5417b or pa 17463b, coarse manual output control switch , rotary type, 1 pole , 6 way ,63 amps, 240 v, ac type pa7163f, fine manual output control switch rotary type, 1 pole , 4 way ,63 amps, 240 v, ac type srpm 615dor pa 5163 d, coarse current limit settor switch cam type, 2 pole ,6 way ,6 amps, 240 v, type s6-61072, fine current limit settor switch, cam type, 2 pole ,6 way ,6 amps, 240 v, type s6-61072, reference electrode selector switch, cam type 2 pole ,4 way ,6 amps, 230 v, type s6-61070, local or remote control mode selector switch,toggle type 2 pole , 2 way ,6 amps, 240 v, , on or off toggle switches in various lamp and meter circuits. 1/2 pole , 2 way ,6 amps, 240 v, , current transformer for ammeter a1 ratio - 50/1, burden - 5 va ,class - 1, contactor 32 amp.bch make 3p +(1p no) with add on 240 v ac coil , breather ( 19.45 mm dia), output voltage setter potentiometer in local auto mode 2.5 k ohm 3 watt ww, output current setter potentiometer in local auto mode 1 k ohm 3 watt ww, oil temp. indicator range ( 0 to 150 o c ), 4-20ma converter module for dc output voltage signal input - 0-75v dc , output - 4 to 20 m a , max load - 600 ohm , accuracy - +-0.5 %, aux supply - 240 v, ac type-520 t, base or channel mounting type , 4-20ma converter module for dc output current signal input - 0-75a (75 mv) dc , output - 4 to 20 m a , max load - 600 ohm , accuracy - +-0.5 %, aux supply - 240 v, ac type-520 t, base or channel mounting type , "auto transformer with coarse and fine tappings for manual control dc of output, input -265 v , coarse taps- 7 nos. fine taps- 04 nos. capacity - 8000 va, insulation - class -a (oil cooled ) ", "main transformer with shield double wound primary- 240 +/- 10 %, secondary- (0-110 v), capacity - 10,000 va, insulation - class -a (oil cooled )", filter choke in dc output , 7.5 mh at 100 amp., control box for card fixing ceco-108 & ceco 105 d1 (and extra card connector having 40 slots), current or voltage control firing card control card , type- ceco- 105d1 , "remote control interface card control card ,type- ceco -108 ", "current limit setter card control card , type- ceco -35a- 2.5 v , 75a/75mv -33.33", "voltage current sensor card control card , type -ceco -19c ", pulse driver card ceco - 118 c, surge suppressor r-c network across scrs 75 ohm, for detailed description refer price breakup sheet, "fuse fail indicator module for diodes and output fuses six channel type with led indicators and 1 common no+nc contacts ,sensing
Tender For work for supply of electrical spare parts for various maintenance under jurisdiction of phed city division ii - udaipur - mcb of breaking capacity not less than 10 ka isi marked is 8828 (1996) conforming to iec 60898 hpl/ indo asian , single pole mcb 6 to 32 amp. , double pole mcb 6 to 32 amp. , triple pole mcb 6 to 32 amp. , triple pole mcb 40 amp , triple pole mcb 63 amp , triple pole and neutral mcb 6 to 32 amp. , triple pole and neutral mcb 40 amp. , triple pole and neutral mcb 63 amp , four pole mcb 25 amp , four pole mcb 32 amp , four pole mcb 40 amp , four pole mcb 63 amp , mccb 16 ka 100 amp 4 pole hpl/ indo asian , mccb 25 ka 200 amp. 4 pole hpl/ indo asian , enclosure for mcb , 4 pole enclosure for mcb , 63 amp tpn din type sdf w/o fuse enclosure , 100 amp tpn din type sdf w/o fuse enclosure , 200 amp tpn din type sdf w/o fuse enclosure , enclosure for mccb , 4 pole mccb hpl / indo asian for tabi , current transformer 10/5 ratio, sv1a class 1 accuracy , current transformer 75/5 ratio sva1 , class 1 accuracy , current transformer 105/5 ratio, sva1 class 1 accuracy , selector switch for volt meter ( 4 position ) as required , ci linked selector switch of 10 a for ampere meter ( 4 position ) , 240/220v , led ( 22.5 mm dia) pilot lamp , red / yellow / green colour , blue colour , heavy duty 230/440 volt power contactor confirming to is 13947-4-1/iec : 947-4-1 having provision of mechanical inter locking din rail mounting type as required , 3 pole ac 3 rating contactor , 4 pole ac 1rating contactor , push button actuator and integral contact block of 22.5 mm dia , abb over loaded relay , abb contactor complete , magnet coil abb , time ctrl. electronic relay on delay timer 0 to 30 sec. abb , "tp&n 415 ac 23 a front handle operated switch disconnector fuse unit, cubical type as required without hbc fuse as required" , 240/415 porcelain kit kat fuse ( hbc type ) as required , hbc links fuse of 80 ka breaking capacity confirming to is : 13703 as required , capacitor , hrc fuse isi marked din type , hrc fuse base isi marked , copper lugs heavy duty (crimping type ) , ampere meter round 4 size , voltmeter round 4 size 0- 500 volt , armored aluminium cable isi marked , ct operated square ampere meter isi marked 96 mm 0 to 100 amp , ct operated square volt meter isi marked 96 mm 0 to 600 amp. , pvc insulated tape inch size , single phase preventor mini gelco , ambari rope 1 size , tyton rubber gasket , pvc copper wire , ci foot valve 5 , ci foot valve 6 , led bulb
Tender For supply of control transformer, type-ii, dry type, class h insulated, 200va, 750v/415v for lhb power cars and ac coaches duly fitted with 4a, 1.2kv fuses link with fuse base for primary side, duly fitted with 2a 500v fuse link with fuse base for secondary as per rdso specification rdso/pe/spec/ac/0203-2020 (rev-0) or latest and as per drawing rdso/pe/sk/ac/0223-2020 (rev-0) sheet-2.