Get complete information related to latest Lt Bus Duct Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lt Bus Duct Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lt Bus Duct Tenders.
Tender For air cooled ducted 16.5 tr ac unit , air cooled ducted 5 tr ac unit , unloading lifting and shifting of 16.5 tr ducted package ac unit at site , unloading lifting and shifting of 5 tr ducted package ac unit at site , installation n2 pressure testing vacummising and commissioning of 16.5 tr ac , installation n2 pressure testing vacummising and commissioning of 5 tr ac , supply and charging of r 410 gas , supply and inst of floor mounted ms stand fabricated out of ms channel , supply and inst of floor mounted ms stand fabricated out of ms angel , hard copper refrigerant piping between indoor and outdoor units , supply and installation of gss ducting as 24g , supply and installation of gss ducting as 22g , acoustic insulation of plenum initial ducting with 10mm thick armasound , supply and fixing of 13mm thick nitrile rubber al foil faced insulation class i , supply and installation of ai powered jet nozzles with volume control damper , supply and inst of ai powered return air grills without volume control dampers , supply and installation of gi opposed blade duct dampers, qty 1.5 sqmtr , supply and fixing of canvas connection , supply and laying of 32mm dia pvc drain piping , electrical cabling 6 c x 1.5 sqmm cu flexible , electrical cabling 3 c x 1.5 sqmm cu flexible , electrical cabling 1 sqmm cu flexible double earthing * /bid number : gem/2026/b/7581741 + /dated: 11-06-2026 ' ' / bid document 1 / 24
Tender For supply of supply of 1.5tr inverter ductable ac as per bsnl specifications , itc of 1.5 tr inverter ductable ac as per bsnl specifications , supply and fixing copper piping of 0.25 inch and0.5inch with nitrite foam insulation as required , supply and fixing powder coated heavy duty ms stand , supply and fixing upvc pipe 25mm dia, 2mm thick , supply and fixing upvc pipe 40mm dia, 2mm thick , supplying and laying pvc insulated frls copper cable 3x1.5sqmm , supplying and laying pvc insulated frls copper cable 3x2.5sqmm , supplying and fixing dp enclosure with dp mcb , supply and fixing 5a to 32 a sp mcb in extg db as required , supplyinstalling,balancingand commissioning gss sheet ducting 0.63mm thick , supplyinstalling,balancingand commissioning gss sheet ducting 0.80mm thick , providing and fixing supply air grills powder coated , providing canvass connection
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, ltbusduct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp
Tender For tender for supply of ducting - pvc ducting for auxiliary fan as per tech specs pdf attached , as per tech specs pdf attached , as per tech specs pdf attached , as per tech specs pdf attached , as per tech specs pdf attached
Tender For providing of facility management services - lumpsum based - government bank; supply of 2 nos 11 tr ductable air conditioner; consumables to be provided by service provider (inclusive in contract cost),facility management services - lumpsum based - government bank; installation and commissioning charges; consumables to be provided by service provider (inclusive in contract cost),facility management services - lumpsum based - government bank; gi ducting with insulation; consumables to be provided by service provider (inclusive in contract cost),facility management services - lumpsum based - government bank; 40 mtr copper refrigerant piping with insulation; consumables to be provided by service provider (inclusive in contract cost),facility management services - lumpsum based - government bank; 40 mtr drain piping (pvc); consumables to be provided by service provider (inclusive in contract cost),facility management services - lumpsum based - government bank; electrical cabling & wiring; consumables to be provided by service
Tender For supply, installation, testing and commissioning of air washer unit consists the following : (i) air cooling machine of capacity 51,000 cmh with 2 nos. centrifugal fans (1 no. working & 1 no. stand by), 2 nos. 15 kw electric motors (1 working one standby), v-belt drive for both the fans, celdek pads, 4 bend pvc eliminators, water pump 0.75 kw (1w+1s), water distribution system with pumps, piping?s, valves etc., air intake filters, g.i. air intake louvers,fan outlet electrically operated actuator dampers and complete in all respect as per spec. (ii) supply with erection of of g.i. ducting- supply air-(a) 0.8 mm ( 22 swg )-160 sq. metre (b) 0.6 mm ( 24 swg )-175 sq. metre (iii) supply, erection and commissioning of supply air grill with vcd of size : 450 x 250 mm-21 nos (iv) supply, installation and commissioning of volume control dampers-2 sq.metre. (v)supply and erection of structural m s support for ducts -500 kg. (vi) supply and erection of gravity air louver size: 300 x 300 mm for exhaust system-21 nos. (vii)supply, erection and commissioning of starter panel drivers -01 set [ warranty period: 36 months after the date of delivery ]