Web Analytics Made Easy - StatCounter

Lt Cables Tenders

Get complete information related to latest Lt Cables Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lt Cables Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lt Cables Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :44853110 Due date: 09 May, 202609 May, 2026 48.00 Lacs
Tender For corrigendum : repair maintenance of high mast lights, street lights street lights, lt cables, garden lights and other miscellaneous works in the area of golf view enclave, 4 para, 4, 3 gr and other locations under ge utilities udhampur

Central Government/Public Sector

CTN :42424475 Due date: 04 May, 202604 May, 2026 NA
Tender For bid to ras supply of flexible copper trailing cables d d - item 10 , item 20 , item 30 , item 40 , item 50 , item 60 cable,trg,atc,3.3kv gr,3.5cx50mm2,is9968 size & tvpe 3.5cx50 sq. mm 3.3 kv grade flexible atc conductor of class-s, epr le-3, insulated &black hofr nbr pvc type se-4 sheathed flexible trailing cable suitable for reeling/un-reeling operation. cable type- flexible, standard: is 9968(part 2) 2002 d.c. resistance at 20deg. c (ohms/km) power core max- 0.393 earth core max - 0.795. annealing test in %- (before stranding) 13.5 %. per sulphate test in g/m2- max. 5.00. conductor screeninq power core only material approx thickness mm - extruded semiconducting compound/ extruded semi conducting tape- 0.80. conductor material: annealed tinned copper, 6.6 klv grade, cable type: flexible, standard: is 9968(part 2) 2002 tests on insulation thickness (nom) mm core ldentification - power core-2.20 colour rpct red, yellow & blue for power cores & green for earth core tensile strength before ageing n/mm2- min.4.20 % variation after ageing (air oven)- max. +-30% % variation after ageing in (air-bb)- max. +- 30%. elongation before ageing in % - min.200% % variation after ageing (air oven)- max. +- 30% % variation after ageing in (air-bb)- max. +- 30%. hot set test hot set elongation- 175% permanent set 15%. lnsulation resistance constant (min.) m ohm km. at 27deg.c- min. 3670 at 90 deg.c-min 3.67. thick of lnner sheath min 2.00 mm. rein forcement- open braid of textile material physical test on outer sheath thickness (nom) / min mm- 3.50/ 2.60 colour black, over all diameter of cable mm- 52.00+-3.00. tensile strength ) /bid number : gem/2025/b/6811700 * /dated: 24-10-2025 & & / bid document 1 / 22 before ageing n/mm2 - min. 11.0 at 2oo elongation 4n/ sq. mm. % variation after ageing in (air-bb)-max. +- 50% elongation before ageing in %- min.250% % variation after ageing in (air-bb)- max. + 50%. hot set test hot set elongation- max.175% permanent set- max 15. oil resistance test variation in % in tensile strength- max. +-40% variation in % in elongation-max. +-40%. tear resistance in n/mm - min.5.0. flammability test period of burning after removal of flame- max. 60 sec. min unaffected portion from the lower edge of the top clamp - min 50 mm. test high voltage at room temp- 10 kv ac for 4 hours. water absorption test increase in capacitance 1 to 14 days max- 6% 7 to 14 days max- 2.5%., control trailing cable 12 c x 2.5 3 p x 1.5 (pair screened) 2 voltage grade 1.1 kv 3 reference standard generally confirming to is: 9968 (part- 1)1998 4 conductor a. material to is:8130/84 annealed tinned copper b. nominal area of cross section(sq. mm) i)-unscreened core (sq. mm.) 2.5 ii) - screened pair (sq. mm.) 1.5 c. flexibility class as per is:8130/84 class-5 d. maximum dc resistance of conductor at 20 deg. c i)-unscreened core (ohms/km) 8.21 ii)- screened pair (ohms/km) 13.7 5 insulation i) material epr type ie-2 to is:6380/84 ii) nominal thickness (mm) 1.0 6 two cores of 1.5 sq. mm. size twisted together to form a pair yes. 7 individual pair screening each pair of 1.5 sq. mm. size taped with rpct, screened with 0.2 mm nom dia of annealed tinned copper wires braid, taped with melinex tape. yes. 8 no of cores / pair i)-unscreened cores 12 ii)-screened pairs 3 9 identification of power cores by number printing on cores. 10 laying up (i) three screened pairs laid up together, taped with rubber proofed cotton tape to form group as "a" (ii) 12 unscreened control cores laid up together around group as "a" of screened pairs and taped with rubber proofed cotton tape applied with open spiral. 11 inner sheath a) material to is: 6380/84 hd hofr csp type se-4 b) minimum thickness (mm) 1.6 12 an open braid of nylon cord reinforced in between inner and outer sheath. yes. 13 outer sheath a) material to is: 6380/84 hd hofr csp type se-4 b) nominal thickness (mm) 2.5 14 nom. overall diameter of cable (mm) 33.0 tolerance on nom. overall dia

Central Government / Public Sector

CTN :45056821 Due date: 06 May, 202606 May, 2026 NA
Tender For supply, installation, testing and commissioning of hvls fan 8 feet sweep with bldc/pmsm motor with gearless drive. down rod (1.5 to 2 mtrs long), hub, aero foil magnalium blades,vfd control panel.metal guy wires (4 pot.) as safety ropes, no. of blades: 6, air volume: 270000 cubic meter per hour, maximum fan speed: 135 rpm, mounting type: ceiling,motor rating: not more than 400 watts, power supply: 220 volts 50 hz ac of make.bharat brayan or similar. [ warranty period: 30 months after the date of delivery ]

Central Government/Public Sector

CTN :45019885 Due date: 19 May, 202619 May, 2026 49.00 Lacs
Tender For ges/pkt/04/2026-27 special repair to replacement of lt cables, junction boxes, lt street light poles, led security lights, lt panels and bus bar of perimeter security light of dhangu mil complex under ge south pathankot

State Government

CTN :44845190 Due date: 15 May, 202615 May, 2026 NA
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - thermal power plant; works contract for digging work for various types of underground ht lt cables as job based activity at gtps colony area including plant inside out..

Central Government/Public Sector

CTN :44816384 Due date: 07 May, 202607 May, 2026 45.00 Lacs
Tender For corrigendum : cwe/chm(u)-140/2025-26 repair and maint of central air conditioning system of capacity 5 x 225 tr, 2 x 48 tr and 3 x 50 tr including lt panels, lt cables, heating system, ahus, fcus and ductings including all connected items at command hospital (wc)

Central Government/Public Sector

CTN :44983724 Due date: 14 May, 202614 May, 2026 45.00 Lacs
Tender For maintenance of lt cables and panels at sapper enclave, mes colony and other locations under ge (utilities) udhampur

Central Government/Public Sector

CTN :44987538 Due date: 15 May, 202615 May, 2026 59.86 Lacs
Tender For special repair for replacement of lt cables at vd road new cantt under ge (west) prayagraj.

Central Government/Public Sector

CTN :45038252 Due date: 22 May, 202622 May, 2026 NA
Tender For supply fiiting fixing of 25 watts all in one solar street light (led based) consist of white led luminaire (led + driver) rating as per configuration along with solar pv modules and lifep04 battery of given capacity, necessary control elecronics, enterconnecting wires/ cables, module mounting structures, etc. to operate from dusk to dawn . the tenderer must provide the led street light that confirm to the technical specification sa per annexure i ( enclosed) [ warranty period: 30 months after the date of delivery ]

corporations/Associations/Others

CTN :45022285 Due date: 06 May, 202606 May, 2026 9.97 Lacs
Tender For laying of 1.1kv lt cables of various sizes in d/s division
 Loading, Please wait...

Connect us via What's Up