Get complete information related to latest Lt Conductor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lt Conductor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lt Conductor Tenders.
Tender For corrigendum : replacement of existing 1st circuit coyote acsr conductor by htls (equivalent to drake acsr) and stringing of 2nd circuit with htls conductor on exisitng dc towers of 66kv anekal-attibele line from 66/11kv anekal sub-station to 66/11kv attibele sub-station for a distance of 6.545kms.
Tender For corrigendum : supply of conductor poles and associated work in daviya aapda edsd jaithra c c - safe carriage of 8.5 m pcc pole , safe carriage of 11 and 13 m stp , safe carriage of 9 m stp , safe carriage of line material , opening binding dog raccon rabbit conductor , opening binding weseal conductor gi wire , opening binding of ab cable , erection of 8.5 m pcc as single support , erection of 9 m stp as single support , erection of 11 and 13 m stp as single support , erecton of 8.5 m pcc double section pole , erecton of 9 m stp double section pole , laying stringing dog raccon rabbit , laying stringing acsr weseal gi wire , laying stringing ab cable , straightening of tilted pcc stp single support , straightening of tilted double pole , opening of ht lt 25 kva 63 kva tf connection , opening of ht lt 100 kva tf connection , dismantelling of old material , re sagging of ht ltconductor , re sagging of ab cable , replacement of brocken damaged accessories , retightening of stay rod , providing and fixing of stay rod , earthing of pcc rs joist stp , carriage of old material , mounting of 25 kva 63 kva tf , mounting of 100 kva tf , chopping of tree branches , repairing resagging new guarding ht line
Tender For corrigendum : supply of safe carriage of 8.5 m pcc pole , safe carriage of 11 and 13 m stp , safe carriage of 9 m stp , safe carriage of line material , opening binding dog raccon rabbit conductor , opening binding weseal conductor gi wire , opening binding of ab cable , erection of 8.5 m pcc as single support , erection of 9 m stp as single support , erection of 11 and 13 m stp as single support , erecton of 8.5 m pcc double section pole , erecton of 9 m stp double section pole , laying stringing dog raccon rabbit , laying stringing acsr weseal gi wire , laying stringing ab cable , straightening of tilted pcc stp single support , straightening of tilted double pole , opening of ht lt 25 kva 63 kva tf connection , opening of ht lt 100 kva tf connection , dismantelling of old material , re sagging of ht ltconductor , re sagging of ab cable , replacement of brocken damaged accessories , retightening of stay rod , providing and fixing of stay rod , earthing of pcc rs joist stp , carriage of old material , mounting of 25 kva 63 kva tf , mounting of 100 kva tf , chopping of tree branches , repairing resagging new guarding ht line
Tender For corrigendum : supply of 50 nos. of drake to drake wedge connectors and 50 nos. of 4 hole paddles for connecting acsr drake conductor required for sharavathy generating station, kpcl, jogfalls - 577435
Tender For estimate for shifting of lt line applied by smt. kamlesh shukla w/o shri kushal shukla near rawatpura phase-i bhatagaon, raipur under rawanbhata zone under city dn. south raipur. 78-035-5156-26-0003 dt. 05.05.26. r56035260055 (d/w-20-i)estimate for conversion of 1 span ltconductor to ab cable applied by shri bajendra pratap singh, near sai nagar professor colony zora raipur under purena zone of city dn. south, raipur. 78-035-5156-26-0005 dt. 13.05.26. r56035260110. (dw-19-i)
Tender For corrigendum : strengthening of existing 220kv dc line from 220/66/11kv bidadi r/s to 220/66/11kv somanahalli r/s by replacing drake conductor to aaac moose conductor.
Tender For a. establishing 2 x 150 mva and 1x12.5mva, 220/ 66/11 kv substation at hanur (mangala) limits.b. construction of 220 kv dc line from 220 kv madhuvanahalli sub-station to the proposed 220 kv hanur sub-station with 220 kv drake conductor for a distance of 13.458 kms.c. construction of 2 nos. of 220 kv terminal bays at 220kv madhuvahalli substation for the proposed 220 kv madhuvanahalli-hanur(mangala) dc line.d.construction of 66kv sc lilo of the proposed 66kv doddinduvadi-hanur line with 110kv dc narrow based towers from proposed 220/66/11kv substation at hanur for a distance of 2.217kms e. construction of 66kv sc lilo of kothanur-bandally line in mc/dc tower from proposed 220/66/11kv substation at for a distance of 2.332kms.f. construction of 66kv sc radial connectivity on mc/dc tower from proposed 220/66/11kv substation at hanur to existing 66/11kv sub-station at ramapura for a distance of 27.428kms.g. construction of 66kv sc radial connectivity on mc/dc tower from proposed 220/66/11kv substation at hanur to existing 66/11kv sub-station at ajjipura for a distance of 19.116kms.h. construction of 66 kv sc radial connectivity from the proposed 220 kv hanur sub-station to 66/11 kv lokanahalli sub-station with 66 kv coyote conductor for a distance of 7.640kms.i. providing 1 no of 66kv terminal bay at existing 66/11kv ajipura sub-station.j. providing 1 no of 66kv terminal bay at existing 66/11kv ramapura sub-station.k. providing 1 no of 66kv terminal bay at existing 66/11kv lokkanahalli sub-station.along with dismantling portion of line tbs on ptk basis.