Tender For corrigendum : rep replacement of existing unsv ltdistributionpanel ug cables and other connected works at bharatpur line tirah line and charri camp and rep of existing unsv lt poles oh conductor ug cables and and other connected works at mil stn dharamshala
Tender For corrigendum : supply of ea set repair at wtr panwadi te bhavnagar - attending fault easet , bcheckservice of dg set 100 to 160 kva , calibration of fuel pump and nozzle 110kva ea , replacement electronic avr 110 to 250 kva ea , sf 10amp 24v smps battery charger , repair of 12 to 24v starter 100 to 250 kva , sf 12v 110ah mf battery , replace faulty part in ea set v belt , replace faulty part in ea set steel braided fuel pipe , replace faulty part in ea set lub pressure pipe , replace faulty part in ea set starter with with key , replace faulty part in ea set ac ammeter , replace faulty part in ea set pla relay , replace faulty part in ea set brass battery terminal , replace faulty part in ea set 16a hrc fuse , replace faulty part in ea set water hose pipe set , replace faulty part in ea set stop solenoid , replace faulty part in ea set minor joint gasket set , replace faulty part in ea set major joint gasket set , replace faulty part in ea set temp guage , replace faulty part in ea set frequency meter , control panel wiring by authorised service technician , service of engine radiator with chemical wash , repair water pump with service at authorised workshop
Tender For supply of ltdistributionpanel consisting of 400a mccb 4 pole 50 ka as incoming microproces sor based and 2x250a, 36 ka, 2x100a, 36 ka, 2x63a, 36 ka, mccb, 4 pole, 2x32a dp mcb 10 ka as out goin g complete with hrc back up fuse with locking arrangement. ltpanel shall be as per cege/grc's specificati on ser/elec/gs/description/lt/panel/1/rev-0/mar 2024. note:- tenderer shall submit tentative gad & te chnical particulars, type test report of same range of ltpanel from nabl accredited laboratory along with th eir bid offer. make of acb/mccb: havells/l&t/ abb/ legrand/ siemens/bch & c&s electric only. [ warranty period: 30 months after the date of delivery ]
Tender For item description- 160 kva, 415 v, 3 phsae, liquid cooled acoustic dg set with electronic gov erner,6 nos cylinder,4strokesrated engine speed 1500 rpm, class of governer a2 or better,brushless altern ator with voltage regulation grade vg3 and class of insulation h ,with amf control panel, ip-55 or higher. di splayed parameters / features - engine speed, lube oil pressure, coolant /cylinder head temparature, engi ne running hours, engine battery voltage,. engine running status , generator voltage (phph), generator vol tage (phn) , generator current (r,y,b)generator apparent power (kva), generator active power (kw), power factor frequency, fuel level, event log, control supply voltage. temperature scanner (rtd, btd) etc. install ation including installation testing and commissioning with foundation making, necessary cabling for conne cting between dg set amf panel conforming to cpwd general specification for electrical works, part-vii or l atest. warranty-24 months. [ warranty period: 24 months after the date of delivery ]
Tender For procurement and installation of a new microprocessorbased electronic governor in place of the existing aseamake turbine governor and runner blade controllerhpc600 including its design manufacture supplyinspection and testing at manufacturer s works beforedispatch delivery along with mandatory spares erectioncabling termination testing and commissioning and itsintegration with the existing mechanical electro hydrauliccontrol unit e40m duly dis-assembling of existingcomplete ehgc governor control panel i e electronicpanel only in the control room along with its old cablesfor unit-2 at nslcph nagarjunasagar telangana
Tender For supply of digitization of driver panel tank d d - k type temperature senssor with modified adopter , pressure sensor with modified adopter , bridge diode circuit speed measurement , encoder circuit rpm measurement , 5w 10k resistor circuit circuit volt measurement , pulse sensor engine hours , microcountroller board electronic control unit , memory card 128 gb micro sd memory class 10 , surge current protection circuit for mother board , mp3208 analog to digital converters , signal amplification circuit , xl 4015 ic dc to dc buck convertor circuit , 4 core shielded cable , soldering lead 250 gram , metal box fabrication , metal connector , capacitor 1000uf 25v , resistor , raspberry pi circuit board with all accessories , lcd display with display driver card 7 inch , warning lamps , interactive software
Tender For supply of electrical protective devices - electrical protective devices ( l & t / legrand / indoasian), mcb single pole, a) 1 a, b) 2 a, c) 3 a, d) 6 a, e) 10 a, f) 16 a, g) 20 a, h) 25 a, i) 32 a, j) 40 a, k) 63 a, mcb double pole, a) 1 a, b) 2 a, c) 3 a, d) 6 a, e) 10 a, f) 16 a, g) 20 a, h) 25 a, i) 32 a, j) 40 a, k) 63 a, mcb tpn , a) 10 amp, b) 16 amp, c) 20 amp, d) 25 amp, e) 32 amp, f) 40 amp, g) 63 amp, mcb triple pole three phase, a) 10 amp, b) 16 amp, c) 20 amp, d) 25 amp, e) 32 amp, f) 40 amp, g) 63 amp, mcb single pole iron box (mds/l&t/indo asian/havel s/siemens/legrand), mcb d.p. iron box (mds/l&t/indo asian/havel s/ siemens/legrand)), mcb tp iron box, mcb four pole iron box, mcb 6 way box (mds/l&t/indo asian), mcb 8 way box (mds/l&t/indo asian), mcb 12 way box (mds/l&t/indo asian/ siemns), mcb tpn db 12 way box (mds/l&t/indo asian), icdp main switch 16 amp. fuse type, icdp main switch 32 amp. fuse type, ictp main switch 32 amp. fuse type, ictp main switch 63 amp. fuse type, ictp main switch 100 amp. fuse type, ictp main switch 200 amp. fuse type, kit-kat 15 amp. 250 volt, kit-kat 30 amp. 440 volt, kit-kat 63 amp. 440 volt, kit-kat 100 amp. 440 volt, kit-kat 200 amp. 440 volt, motor protection circuit breaker . as per is/iec : 60947-4-1 (l&t/indo asian/siemens/legrand), a) 0.4 to 0.63 amp, b) 0.63 to 1.6 amp, c) 1.6 to 2.5 amp, d) 2.5 to 4 amp, e) 4 to 6 amp, f) 5.5 to 8 amp, g) 7 to 10 amp, h) 10 to 13 amp, i) 13 to 18 amp, 1) star delta starter 10 h.p. (l&t/ siemens), 2) dol starter(0.5 hp to 5hp), 3) 4 pole contactors 16 amp, 4) 4 pole contactor 25 amp, 5) 4 pole contactor 40 amp, 6) 4 pole contactor 95 amp, 7) 4 pole contactor 125 amp, 8) contactors for 10 hp motors (mk), 9) on delay timer (eletx), 10) off delay timer (eletx), 11) timer (3-10 sec), a) c - channel for mounting mcb & contactor within panel, b) d rail channel for mounting mcb, mpcb & contactors, relay within panel., hrc fuse, a) 4a, b) 6 a, c) 10 a, d) 16 a, e) 20 a, f) 25 a, g) 32 a, h) 40 a, i) 63 a, j) 100 a, k) 200 a, m) 400 a, fuse wires, a) 5 a;, b) 10 a;, c) 16 a;, d) 25 a;, e) 32 a;, f) 63 a;, over load relay as per is/ iec : 60947-4-1 ( l& t, siemens, legrand, indoasian), a) 0.4 to 0.63 amp, b) 0.63 to 1.6 amp, c) 1.6 to 2.5 amp, d) 2.5 to 4 amp, e) 4 to 6 amp, f) 5.5 to 8 amp, g) 7 to 10 amp, h) 10 to 13 amp, i) 13 to 18 amp, mccb four pole ( l& t, siemens, legrand, indoasian), a) 32 amp, b) 40 amp, c) 63 amp, d) 100amp, e) 125amp, f) 200 amp, g) 250 amp, h) 400 amp, elcb ( l& t, siemens, legrand, indoasian), a) dp 16 amp, b) dp 25 amp, c) dp 40 amp, d) fp 16 amp, e) fp 25 amp, f) fp 40 amp, g) fp 63 amp, h) fp 125 amp, rccbconforms to is : 12640 & iec 61008-1,degree of protection : ip 20,sensitivity rating : 30ma / 100ma / 300ma short circuit with stand capacity of 10ka with scpdon-off indication,test button t is provided for periodic check up, a) dp 25 amp, b) dp 40 amp, c) dp 63 amp, d) fp 25 amp, e) fp 40 amp, f) fp 63 amp, switch fuse unit three phase, hrc type (l & t, indoasian, siemns), a) 125 amp, b) 200 amp, c) 400 amp, level cotroller (l & t, siemens, gic, ), a) for single tanks control, b) for two tanks control, level sensing probes (ss), level monitoring switches, floating switch with two contacts (no+ nc), magnetic level sensing probe, electronic timer chrono (radix, gic, siemens, schnider), electronic timer astrological (radix, gic, siemens, schnider), vertical tpn db with provision for mccb upto 125 aas incomer (indoasian /havells/siemens), a) 4 way, b) 6 way, c) 8 way, earthing plate, 1) copper 300x300x3, 2) copper 600x600x3, 3) g.i. plate 600x600, 4)g.i. bare conductor, 5)copper bare conductor (10swg), 6)g.i. strip, 7)copper strip
Tender For tender for ltdistributionpanel of 630 kva,11/0.4 kv pungh-ist in electric section local-ii under esd sundernagar ch. to:- estimate for providing sop to lwss gp chowk,mahadev , chambi, upper behli, palota jaidevi & bhalana in tehsil sundernagar having pump house at village dhamol gp lower behli, village shilnu gp jaidevi & near forest rest house in gp chambi under esd/sssd sundernagar. (ts. no:- 08/2022-23 circle s. amount:- 77,18,725/- ) ( wbs no_ d-22-0797)