Web Analytics Made Easy - StatCounter

Lt Distribution Panel Tenders

Get complete information related to latest Lt Distribution Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lt Distribution Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lt Distribution Panel Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45726505 Due date: 20 Jul, 202620 Jul, 2026 45.00 Lacs
Tender For repair/maintenance of diesel generator set with central panel and other connected items at zone 5 and 1(a,b,c) zone 1, 3 (a and b), zone 2 and zone 4 under ge (s) tezpur - maint and servicing of dg set 320-400 kva conopy type with amf panel (if installed ), through authorise service agency of oem , including replacment of defective/wornout parts with new spares such as filters, gaskets, v belts, engine oil, coolant for radiator rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner , including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water and cleaning of pol tank and radiator etc complete all as specified and directed.note:- 1. spares required for above maint will be measured and paid separately under relevent items of schedule. 2. all breakdown calls should be attended., all as per item no-1 above but for dg set of capacity 180-250 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 125-160 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 40-100 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 10-35 kva complete all as specified and directed, supply only fuel filter for 300-400 kva dg set, complete all as specified and directed, supply only fuel filter for 125-250 kva dg set,complete all as specified and directed complete all as specified and directed, supply only fuel filter for 10-100 kva dg set,complete all as specified and directed, supply only lub oil filter for 300-400 kva dg set,complete all as specified and directed, supply only lub oil filter for 125-250 kva dg set,complete all as specified and directed, supply only lub oil filter for 10-100 kva dg set,complete all as specified and directed, supply only air cleaner filter ( inner and outer ) for 300-400 kva dg set, complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 125-250 kva dg set,complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 10-100 kva dg set,complete all as specified and directed, supply only bypass filter for 300-400 kva dg set, complete all as specified and directed, supply only bypass filter for 125-250 kva dg set,complete all as specified and directed, supply only bypass filter for 10-100 kva dg set,complete all as specified and directed, supply only v belt for 300-400 kva dg set, complete all as specified and directed, supply only v belt for 125-250 kva dg set, complete all as specified and directed, supply only v belt for 10-100 kva dg set, complete all as specified and directed, supply only coolant for radiators complete all as specified and directed., supply only engine oil multi grade 15w40 complete all as specified and directed., s & f in repair display control panel ( base card) for 10 to 100 kva dg set complete all as specified and directed ., s & f in repair display control panel (base card) for 125 to 250 kva dg set complete all as specified and directed., s & f in repair display control panel (base card) for 300 to 400 kva dg set complete all as specified and directed., s & f in repair fuel actuator with o ring for 300 to 400 kva dg set complete all as specified and directed., s & f in repair key switch for 10 to 400kva dg set complete all as specified and directed., s & f in repair coolant temperature sensor (coolent control safety) for 10 to 400kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 10 to 100 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 125 to 250 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 300 to 400kva dg set complete all as specified and directed., s & f in rep

Central Government/Public Sector

CTN :45450690 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For corrigendum : repair repl of intl elct wks incl rewdg of clg fan exh fan w/m fan lt ftgs sub main wirg geyser and oth allied wks incl ot lts at ph i of mh kke repair maint of diesel generator set amf pnls synch pnl and allied wks at mh kke range hls area hq 41 arty div and aund - repair replacement of internal electric works including rewinding of ceiling fan, exhaust fan, wall mounted fan, light fittings, sub main wiring, geyser and other allied works including ot lights at phase-1 of mh khadki including 41 arty div and repair and maintenance of dg set, amf panels, synchronising panel and allied works at mh khadki, range hills area, hq 41 arty div and aundh military complex under ge (mh & rh) khadki

CTN :45705023 Due date: 03 Jul, 202603 Jul, 2026 10.02 Lacs
Tender For repair maintenance of various e&m services (ei, fans, lifts, fas) in b block, block no.9 to 14 at cgo complex, lodhi road, new delhi. (sh: routine comprehensive maintenance of 620 kva & 400 kva kirloskar make diesel generator set with amf panel)

Central Government/Public Sector

CTN :45365872 Due date: 06 Jul, 202606 Jul, 2026 44.50 Lacs
Tender For corrigendum : repair/ maint of lt distribution panel, feeder panel box, apfc panel, lt isolation transformer and other connecting allied works at af stn mohan bari, alg along walong under ge (af) mohanari

Central Government/Public Sector

CTN :45447246 Due date: 03 Jul, 202603 Jul, 2026 43.54 Lacs
Tender For corrigendum : special repairs to lt distribution panels and allied works at icgs kavaratti under ge navy lakshadweep - special repairs to lt distribution panels and allied works at icgs kavaratti under ge(navy) lakshadweep

CTN :45690396 Due date: 02 Jul, 202602 Jul, 2026 25.59 Lacs
Tender For annual maintenance contract of installed e&m equipments in central drug standard control organization, gothapatna, bhubaneswar for financial year 2026-27. - & minor repairs of cctv & including, & minor repairs of kone lift i/c, (standard deviation colour matching), (standard deviation colour matching), (t.c.). manufactures word mark/, (unified glare rating) < 19, flicker, / 6500°k (as per ansi bin), sdcm, /6500°k (as per ansi bin),sdcm, <3,, <5, maximum power consumption, >85%, input voltage: 140-270 volt ac,, >85%, operating voltage ac 140-270, >85%, operating voltage ac 140-270, >85%,thd < 10% as per iec 61000-, 1 2,22,718.00 job 2,22,718.00 mr, 1 no 13 passenger lift,, 1.5 sq. mm frls/hffr, pvc, 10% , p. f.≥0.95, ip20, cri ≥80, ugr, 10.1 18 watt 10 618.00 each 6,180.00 mr, 10322 with driver as per the, 11.1 36 watt 10 2,103.00 each 21,030.00 mr, 12 13,877.00 month 1,66,524.00 mr, 12 16,961.00 month 2,03,532.00 mr, 12 21,586.00 month 2,59,032.00 mr, 12 24,086.00 month 289032 mr, 12 24,128.00 month 2,89,536.00 mr, 12 31,890.00 month 382680 mr, 12 4,490.00 month 53,880.00 mr, 12 53,452.00 month 6,41,424.00 mr, 125 kva dg set with amf and, 15u rack 1 13,330.00 nos 13,330.00, 2 x 6 sockets 16a power distribution, 2.5 kv with short & open circuit, 3-2, p. f.≥0.95, ip-66,ik-10, cri >70,, 39.23.3, 4000°k/ 5700°k /6500°k (as per ansi, 61000-4-5, driver efficiency, 70% of initial lumen maintained till life, 70% of initial lumen maintained till life, 90°c)., 90°c)., above 90°c)., aluminium body including trim, aluminium body with driver as per the, and earthing etc. as required with, annual comprehensive maintenance, annual comprehensive, maintenance, annual comprehensive, maintenance, approved by engineer-in-charge as, approved by engineer-in-charge as, approved by engineer-in-charge as, as required, as required., at gothapatna as required, attached & following staff., basis as per terms & conditions, basis) including servicing, preventive, bin), sdcm (standard deviation, bis standard complete in all respect, bis standards and trade mark, body material with pmma and, cable and earthing etc. as required, cable and earthing etc. as required, cables, nvr, switch, cctv camera,, cct 3000°k / 4000°k / 5700°k, cdtl building etc. as reqd., centigrade, internal surge protection of, certificate (t.c.). manufactures word, circuitry) of minimum 50000 burning, colour matching) <3,, commissiong of pa, rectification and, comprehensive and repair, comprehensive and repair, comprehensive and repair, condition at cdtl office building etc, contract (as inspection on monthly, copper conductor single core cable, day electrical complaints, complaint, distribution pane, 250 kva substation,, down lighter (round/ square/, driver & electrical circuitry), of, dsr-25, efficacy ≥105 <120 lm/watt) supplying, ends , cct 3000°k / 4000°k / 5700°k, ends as per lm80 extrapolation ies, entire lift , etc in cdtl office building, etc in cdtl office at gothapatna as, extrapolation ies tm-21-11 report,, fixture shall be confirming to relevant, fixture shall be of relevant bis, fixtures as per bis shall be submitted., fixtures as per bis shall be submitted., fixtures as per bis shall be submitted., free, (flicker should be below 5 %), life, frequency 50/60 hz, operating temp, general shift) at cdsco on monthly, hours with70% of initial lumen, housing such that led, housing such that led junction, housing such that led junction, i/c external connections with 1.5, in all respect i/c external connections, inspection on monthly basis) including, inspection on monthly basis) including, insulated copper conductor single core, insulated copper conductor single core, internal surge protection of 2.5 kv with, ip surveillance systems i/c maintance, ip20, cri ≥80 , ugr (unified glare, junctiontemperature shall not rise, knocked-down condition (ckd) shape,, led panel light 2x2 ft. (system lumen, lenses for beam angle asper iesna, life time (led, driver &

Central Government/Public Sector

CTN :45397531 Due date: 01 Jul, 202601 Jul, 2026 33.00 Lacs
Tender For corrigendum : repair/maint of dg sets, amf panels, lt panel and allied wks at lms under ge 869 ews.

Central Government/Public Sector

CTN :45633936 Due date: 16 Jul, 202616 Jul, 2026 59.67 Lacs
Tender For maint and repairs to lt distribution panels, lt ug cable network and associated works for various units under ge (a) jaisalmer

State Government

CTN :45558226 Due date: 24 Jun, 202624 Jun, 2026 34.31 Lacs
Tender For corrigendum : tender for prov. and fixing of equipment / material , design, erection, testing , commissioning for sop to jsv for inspection hut at cheel bangla chowari by prov. 11/0.4 kv 100 kva dtr along ht, lt line in es chowari-ii (u) esd chowari ed dalhousie - (a) supply part-11/.4 kv 100 kva distribution sub station, 11/.4 kv 100kva dtr (rec sep. ord 11/1976, prov. st pole pole 9 mtr. long w/l 220kgs, muff for steel tubular pole with concrete filling, x-arm: [channel iron (100x50x5 mm), length : 2800 mm x 2 nos] for incomer line, ms a.i.(50x50x6 mm), length: 2800 mm x(2 nos for las ), x-arm: [channel iron (75x40x5 mm), length : 2800 mm x 4 nos] for supporting do fuse unit & go switch, x-arm: [channel iron (100x50x6 mm), length : 2800 mm x 2 nos] for transformer bed, x-arm [channel iron (100x50x6 mm), length : 460 mm x 2 nos for supporting main channel of transformer], ms a.i.(50x50x6 mm), length: (2800 mm) x 1 no., ms a.i.(50x50x6 mm), length: (950 mm) x 2 nos. of bed knee bracing, ms angle iron (50x50x6 mm), length : (2800 mm) x2 nos for transformer lt distribution box and g.o switch fixing assembly, g.i. wire for earthing, ms angle iron (50x50x6 mm), length : (450 mm)x1 nos for transformer lt distribution box and g.o switch fixing assembly, g.o. switch handle supporting: [c.i. (75x40x6mm), length: 460mm for transformer lt distribution box and g.o switch fixing assembly, g.o ab switch unit (11kv,400,663ka) tripple pole o/d type, d.o fuse unit, surge arrester, 9 kv station class, discs insulator sets (comp. 1 no. disc: ^^(porcelain, bs, 12 kv, 90 kn) i/c dead end clamps etc.), stay set complete, stay wire (7/3.15mm)( 10 kg per stay set), pipe earthing with gi,charcoal & salt, prov. lt distribution panel with mccb (160 a, 10 ka, 4p,1 no.) & sfu (32 a 5 no. rewireble) for 100kva trf. as per specification, half clamp (m.s. flat 50x6), full clamps (m.s. flat 50x6), m. s. nuts & bolts off sizes (galvanised coated) [prefarably 16mm or more (with flat and spring washer), aluminium thimbles 300 mm sq., copper thimble 200 mm sq., danger plate, barbed wire (rec sp f 3/1981), lt cable 3-1/2 core-185mm sq., alluminium paint, prov.acsr, 6/1/3.35 mm, chain link fencing , angle iron, gate etc. for transfromer fencing, prov. transformer bed plinth for 1x400kva s/stn structure complete with cc 1:6:12 r.r. massonery & plastering etc. a/w chain link fencing, angle iron gate etc. for dtr fencing., lt switched caapcitors 36-kvar for 100 kva dtr, trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure)., supplying and stacking of good earth at site including royalty and carriage upto 5 k m lead complete (earth measured in stacks will be reduced by 20% for payment)., fine dressing of the ground., spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately)., supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) : screened through sieve of i.s. designation 20 mm, filling mixture of earth and sludge or manure in the desired proportion in trenches, flooding with water and leveling (cost of supplying earth and sludge or manure and mixing excluded)., providing and fixing korean grass turf superior qualitywith earthy 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden (dhurmos) and than rolling the surface with light roller make the surface smoothen and light, watering with sprinkler and maintenanc

Central Government And Public Sector

CTN :45632377 Due date: 11 Jul, 202611 Jul, 2026 NA
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; electrical system or installation, repairing and servicing of amf panel; service provider
 Loading, Please wait...

Connect us via What's Up