Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c-423; l006 during boat davit operation smoke observed from control transformer in controlpanel of boat davit and abnormal noise observed from hoisting gearbox lim..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c-423; l013 port blower of water jet compartment is not getting start zero insulation measured suspected winding burnt defect to be identified and rectified and sys..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c-423; l022 smoke observed from ac controlpanel during operation di dr carried out by ss and observed contactor coil and no nc switch burnt out contactor coil and..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c-423; l 023 main engine control battery charger is non operational defect identification carried out by ss and observed that control pcb is burnt same to be repair..
Tender For repair replacement and improvement of existing ltpanel sub panelcontrol cables dbs mccbs mcbs contactor timer voltmeter ammeter armoured cable and earthings with connected accessories and allied works of e/m-ii ac plant installation un
Tender For auction sale of rolling stock - condemned bg 8 wheeler- ac coach with all available ferrous-non ferrous-wooden fittings thereon but excluding the following reclaimable items-mechanical rc items:1)buffer plunger with buffer pads and buffer causins,2)bio-toilet complete set.3)distributor valve complete. electrical items: 1)all type of batteries,2)rmpu unit if,3)regulator,4)ac controlpanel if. coach number- 1) special repair ce 79890,2) special repair re 94152= 2 coaches, pl.no. 98111061, ds8 no: 232841 (101021 &101017 ) dt.20.04.2024. location: tondiarpet marshalling yard, custodian: sse/c&w/tnpm, note: 1) at the time of delivery all items including zero value items such as rexene, rubber, frp etc., should be removed and cleared by the purchaser from railway premises and should be disposed as per the existing norms of central/state government.d and cleared by the purchaser from railway premises and should be disposed as per the existing norms of central/state government,2) all rc items should be handed over to custodian at respective locations,3) screw couplings to be defaced before delivery. rate per number should be quoted,4)coaches are in grounded condition (bogies and wheel sets removed ). 5) ac coaches converted into inspection car & mobile training car and compartments & berths were removed, 6) coach no.sr re 94152 = ac units removed. . 7)rate per number should be quoted, 8)cutting permitted to loadable sizes only, 9) crane/jcb loading is permitted. (10) purchaser should take safety precaution while cutting/delivery of coaches.
Tender For mecgale make ash handling spares from oem - ## mecgale make dome type valve assembly complete with pn. accessories but excluding pn. controlpanel. model no. 3/12/4##, 300 nb assembly, 300 nb assembly (w/c top plate & dome), * 300 nb dome type valve*, dome shaped head, dome shaped head (water cooled), inflatable seal (neoprene), inflatable seal (silicon), top plate, top plate (water cooled), insert ring, spigot piece, o ring for spigot piece, shaft, shaft (water cooled), shaft seal, shaft seal spacer, shaft bush, external lip seal, dowel pin inner, dowel pin outer, shaft boss with torque arm, shaft boss with striker arm, shaft boss with torque arm (w/c), shaft boss with striker arm (w/c), set of gasket, set of pneumatic fittings for valve assly., rotary joint for w/c inlet valve, neoprene rubber seal, * pneumatic panel *, single solenoid valve (rotex, 230vac), coil for single solenoid valve (230vac), seal kit for single sol.valve, 1/2 single solenoid valve , (rotex, 230vac), coil for 1/2" single solenoid valve , (230vac), seal kit for 1/2" single sol.valve, seal pressure gauge, warree, vessel pressure gauge, warree, pressure switch(seal pressure) rt116, indfos, pressure switch (vessel low pressure) rt112, pressure switch (vessel high pressure), * others *, air limit switch 1/4 (nucon), seal kit for air limit switch, air lubricator for pn. panel (1/2" / shavo norgen), air filter for pn. panel (1/2" (shavo norgen), air filter for vessel pressure (1/4" (shavo norgen), blow valve 50nb, seal kit for blow valve 50nb, repair kit for blow valve 50nb, pneumatic cylinder 6 x 12 , seal kit for 6" x 12" pneumatic cylinder, front clavish for 6" x 12" pneumatic cylinder, front clavish for 4" x 8" pneumatic cylinder, flexible hose 3/4" x 1000mm, flexible hose 1/2" x 1000mm, conveying nrv 50 nb, seal kit for conveying nrv 50 nb, repair kit for conveying nrv 50 nb, conveying nrv 20nb, seal kit for conveying nrv 20nb, repair kit for conveying nrv 20nb, pneumatic nrv 1/2" (schrader), pneumatic nrv 1/4" (schrader), quick exhaust valve 3/4", diaphragm for quick exhaust valve 3/4", quick exhaust valve 1/4", diaphragm for quick exhaust valve 1/4", bleed nipple 1/4" x 1.5mm (for inlet valve ), bleed nipple 1/4" x 0.5mm (for vessel pressure), * spares for reverse pulse jet bag filter *, filter bags 144 x 2000mm (pnf), cages 2m long, ventury 144, pulse valve (size 1"),230v ac, diaphragm fo pulse valve1", coil for pulse valve 1", 230v ac, * ash conditioner *, spray nozzle 1/2", adjustable paddles, fixed paddles
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - office space; 2 hp submersible slr no 01; service provider,repair, maintenance, and installation of plant/ systems/equipments (version 2) - office space; controlpanel of 15 hp submersible pump slr no 02; service provider,repair, maintenance, and installation of plant/ systems/equipments (version 2) - office space; 4 kva stabilizer of ac slr no 03; service provider