Web Analytics Made Easy - StatCounter

Lt Fuse Tenders

Get complete information related to latest Lt Fuse Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lt Fuse Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lt Fuse Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45491123 Due date: 07 Jul, 202607 Jul, 2026 10.00 Lacs
Tender For corrigendum : repair replacement of lt ug cables, poles, acb, voltage stabilizer, lt panel, earthing and connected accessories at mil stn gaya

CTN :45551266 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For w acting for and on behalf of the president of india invites e-tenders against tender no e-73-dyceekgpw-cbc-26-27 closing date/time 01/07/2026 15:00 hrs. bidders will be able to submit their original/revisedbids upto closing date and time only. manual o ers are not allowed against this tender, and any such manual o erreceived shall be ignored.1. nit headername of workupgradation of cbc overhauling section and corrosion repair shop of wagonrepair shop, kharagpur workshop.bidding typenormal tendertender typeopenbidding systemsingle packet systemtender closing datetime01/07/2026 15:00date time of uploadingtender09/06/2026 16:38pre-bid conferencerequirednopre-bid conference datetimenot applicableadvertised value 2402108.76tendering section elegenbidding style single rate for tender bidding unitabove/below/parearnest money (rs.) 48100.00validity of offer ( days) 60tender doc. cost (rs.)0.00period of completion 18 monthscontract type works - general contract category expenditurebidding start date 17/06/2026are jv allowed to bid nonumber of jv memberallowed0are consortium allowedto bidnonumber of consortiummember allowed0ranking order for bidslowest to highest expenditure typecapital (works)2. schedules.no. itemcodeitem qtyqty unitunit ratebasic value escl.(%) amount biddingunitschedule () a-cost of supply of material for electrical work1712792.421a12.00numbers383500.00 767000.00 at par 767000.00description:- supply of incoming 1x 630a,4p, 50ka mdo type microprocessor based acb withipr1+ release & outgoing (i)2 x 320a,4p, 36ka thermal magnetic release with adjustable thermal &fixed magnetic mccb (ics=100%icu),(ii)2 x 200a,4p, 36ka thermal magnetic release withadjustable thermal & fixed magnetic mccb (ics=100%icu),(iii)4 x 100a,4p, 36ka thermal magneticrelease with adjustable thermal & fixed magnetic mccb (ics=100%icu) tted in lt panel box14swg crca sheet powder coated 4way cu busbar of suitable rating, indicator lamp, digitalmultifunction meter & all other accessories. mccb & acb make:- havellls/ lk/ schneider/siemens.2a210.00numbers 400.02 4000.20 at par 4000.20description:- supply of mcb metal enclosure 4 pole3a380.00numbers 413.00 33040.00 at par 33040.00description:- supply of pyramid insulator as per drawing4a470.00numbers 531.00 37170.00 at par 37170.00description:- supply of pin type insulators as per drawing.5a550.00numbers1121.00 56050.00 at par 56050.00description:- supply of gi-angle (40 x 40 x 06 mm) bracket 4 way with porcelain insulator as perdrawing suitable for overhead light.6a610.00numbers 248.98 2489.80 at par 2489.80description:- supply of mcb metal box 2 pole7a720.00numbers1323.96 26479.20 at par 26479.20description:- supply of 16/20/25a power unit (containing 4 module plate, starter, socket and plug)for ac unit.8a85.00numbers11434.20 57171.00 at par 57171.00description:- supply and testing of oscillating type bldc pedastal fan, 230 v,400 mm sweep,multi speed, remote/button controlled make- atomberg, havells, crompton, bajaj, usha, orient.9a9 150.00 metre1150.50 172575.00 at par 172575.00page 1 of 18run date/time: 09/06/2026 16:38:46kgp-workshop-electrical/south eastern rlytender documenttender no: e-73-dyceekgpw-cbc-26-27closing date/time: 01/07/2026 15:009description:- supply of hot dip galvanized 2mm thickness perforated cable tray of size 300 mmwidth and 50 mm height and complete accessories as per is, ie rules and site requirement10a10 50.00 metre 575.25 28762.50 at par 28762.50description:- supply of cable trays 2mm thickness size 100 x 50 mm gi, perforated (rmt) withcover complete and as per is, ie rules and site requirement.11a11 10.00numbers 180.54 1805.40 at par 1805.40description:- supply of combined switch socket box - 16 a, capton 5-in-1 combined switch andsocket with isi mark,as per is:3854 or latest12a122.00numbers34700.26 69400.52 at par 69400.52description:- supply of 4 pole mccb ,release range (80-200)a, breaking capacity 36 ka,microprocessor release with inbuilt earth pr

Central Government And Public Sector

CTN :45703531 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For providing of repair and overhauling service - servicing of l&t make air circuit breaker (rating from 800a to 1600a) inclusive of maintenance kit for each acb; servicing of l&t make air circuit breaker (rating from 800a to 1600a) inclusive of maintenance kit for e..,repair and overhauling service - servicing of l&t make air circuit breaker (rating from 2000a to 2500a) inclusive of maintenance kit for each acb; servicing of l&t make air circuit breaker (rating from 2000a to 2500a) inclusive of maintenance kit for..,repair and overhauling service - servicing of l&t make air circuit breaker (rating 4000a) inclusive of maintenance kit for each acb; servicing of l&t make air circuit breaker (rating 4000a) inclusive of maintenance kit for each acb; no; buyer premise..

Central Government/Public Sector

CTN :45469070 Due date: 02 Jul, 202602 Jul, 2026 6.75 Crore
Location: Goa - Goa Goa - Goa
Tender For corrigendum : annual operation & day to day maintenance of internal & external e&m installations at goa international airport for the year 2026-2028. - servicing, testing and checking of breakers , "servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. l&t make acb of rating 800-1600 a " , "servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. l&t make acb of rating 2000 a - 2500a " , servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. l&t make acb of rating 3200a - 4000a , servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. schneider make acb of following rating , servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. ge make acb of following rating , one time servicing, checking and testing of 33kv vaccum circuit breakers (vcb) including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. make jyoti , servicing, checking and calibration of the following relays as per recommended standards and submission of calibration report complete as required through authorised agency of oem / agency approved by engineer-in-charge. , servicing of 3x 4kw grundfos make hydropneumatic pumps along with control panel which includes cleaning, safety check, motor, gear box, drive check, vfd parameters check etc. as per oem recommendation through oem or authorised service partner of oem. , servicing of 0.55 kw - 5kw grundfos make pumps which includes cleaning, safety check, motor, gear box, drive check etc. as per oem recommendation through oem or authorised service partner of oem. , dehydration & filteration of transformer oil of 1000 kva transformer of aai residential colony to improve the breakdown voltage of oil up to 50 kv by oil filtration machine and carrying out bdv test of oil, top up of transformer oil etc. by keeping the dehydration equipment out side the 33kv yard including transportation of filtration machine up to site etc. complete as required (excluding the cost of transformer oil). , "the execution of items mentioned in cpwd, delhi schedule of rates (e&m) 2025 for electrical repair and maintenance of electrical e&m installations as and when required as per direction of engineer-in-charge at goa airport for period of two years. agency will quote against basic rate of rs. 5,00,000.00 (say x) (including gst) in ""rate column"" for examples : (i) if bidder is quoting rs. 4,00,000.00 (including gst) (y1) then it will be

State Government

CTN :45706710 Due date: 03 Jul, 202603 Jul, 2026 1.82 Lacs
Tender For special repair to h.t.substation (including vcb,acb,transformer,mccb) at district court ,modasa,dist:arvalli [2nd attempt]

Central Government And Public Sector

CTN :45279869 Due date: 29 Jun, 202629 Jun, 2026 2.90 Lacs
Tender For bid to ras corrigendum : supply of service 11 kv ht panel as per sepcifications , sf new mineral oil for panel etc as per sepcifications , calibration relay etc as per sepcifications , replacement digital ammeter for ht panel , replacement digital voltmeter for ht panel , replacment ryb ind lamp led type in ht panel , sf 2a hrc fuselink in ht panel , servicing 1500kva dry type transformer as per sepcifications , servicing 2 runs 2500a tpn bustrunking as per sepcifications , service mv lt panel with 2500a 4p acb 3 nos as per specifications , service mvlt panel with mccb incoming as per specifications , checking and repair of em intelocking , dismentaling 3.5 sq mm 240 or 300 sq mm al cable as required , pf adaptor box aprx 1.5 ft x 1.5 ft x 1.5ft of 16swg ms sheet as reqd , pvdg panel module door key as reqd , pvd and fixing operating handle for 250a 4p changeover as reqd , replacement 160a hrc fuse with base in extg cap panel , replacement 3p 50kvar cap duty contactor in extg cap panel , replacement 25sq mm cu lead wire 1ft length in extg cap panel , checking etxg 2no 25kvar cap bank and fault repair reinstallation , dismentaling uv protection connections as reqd , replacement digital ammeter for lt panel , replacement digital voltmeter for lt panel , replacment selector switch in lt panel , replacment ryb ind lamp led type in lt panel , sf 2a hrc fuselink in lt panel , sf 32a hrc fuseling incl removing faulty item from lt panel as reqd , sf 63a hrc fuseling incl removing faulty item from lt panel as reqd , sf 100a or125a hrc fuseling incl removing faulty item from lt panel as reqd , sf 250a hrc fuseling incl removing faulty item from lt panel as reqd , sf new 5 or 6 amp piano switch in replacement of faulty item , sf new 5 or 6 amp 3pin socket outlet in replacement of faulty item , sf new 15 or 16 amp piano switch in replacement of faulty item , sf new 15 or 16 amp 6pin socket outlet in replacement of faulty item , rewinding ceiling fan motor , sf 4ft 20w led fitting against faulty fitting , service of 750kva dg set as per specification , service dgset control panel 1250a 4p acb as per specification , repacement ryb ind lamp in dg set panel , repacement digital ammeter in dg set panel , earthing testing in existing earth pits and report submission

Central Government/Public Sector

CTN :45435649 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For corrigendum : geafu-30 of 2026-27 repair and maint of lt panel , bus bar, cable end jointing kit, replacement of mccbs, relay, acb, feeder pillar and certain allied works at 39 wing af stn udhampur

State Government

CTN :45640057 Due date: 06 Jul, 202606 Jul, 2026 70.00 Lacs
Tender For supply of fuse set from esc mnp , carriage of 11 kv tpmo with polymer insulator from esc mnp , carriage of complete stay 9gi stay rod 20x1800 mm etc material from esc mnp , carriage of distribution transformer 25 kva from esc mnp , carriage of distribution transformer 63 kva from esc mnp , carriage of distribution transformer 100 kva from esc mnp , carriage of distribution transformer 250 kva from esc mnp , carriage of acsr weasel conductor from esc mnp , carriage of m s earthing rod 20 x2540 mm from esc mnp , carriage of lt al. xlpe cable size 1x240 sq.mm. from esc mnp , carriage of lt xlpe cable 1x120 sq.mm. for dtr from esc mnp , carriage of lt xlpe cable 1x400 sq.mm. for dtr from esc mnp , carriage of lt xlpe cable size 3.5x70 or 35 sq.mm. from esc mnp , carriage of lt ab cable 3x120 1x95 1x16 sq.mm. from esc mnp , carriage of lt ab cable 3x50 1x35 1x16 sq.mm. from esc mnp , carriage of lt ab cable 3x95 1x70 1x16 sq.mm. from esc mnp , carriage of 33 kv xlpe cable 3x300 sq.mm. from esc mnp , carriage of 33 kv indoor or outdoor jointing kit size 3x300 sq.mm. from esc mnp , carriage of 33 kv straight through size 3x300 sq.mm. from esc mnp , carriage of g.i. wire 6 or 8 swg for guarding from esc mnp , carriage of three phase distribution box from esc mnp , erection of fixing of lt fuse set protection box with all respective accessories as per norms , execution of chemical earthing with g.i. patti clamp nut and bolts as per norms , erection of l.t. tail less unit with all respective material as grouted angel with fabrication work etc. , laying of acsr weasel conductor , laying of lt ab cable 3x120 1x95 1x16 sq.mm. , laying of lt ab cable 3x50 1x35 1x16 sq.mm. , laying of lt ab cable 3x95 1x70 1x16 sq.mm. , mounting of three phase distribution box , erection of double pole structure 8.5 mtr pcc pole , erection of single pole structure 8.5 mtrs pcc pole , erection of tri pole structure 33 kv 13 mtr st pole , grouting of pcc or stp pole , grouting of stay , earthing of pole , guarding of 11 kv line , fencing of 250 kva distribution transformers , plinth for 250 kva transformer , installation of 11by0.4 kv tf 25 kva , installation of 11by0.4 kv tf 63 kva , installation of 11by0.4 kv tf 100 kva , installation of 11by0.4 kv tf 250 kva , laying of 33 kv xlpe cable 3x300 sq.mm. , installation of 33 kv indoor or outdoor jointing kit size 3x300 sq.mm. as per norms. , dismentlling, received back and safe carriage of jarjar g.i. wire and weasel conducter including with rolling from pit site to esc, mainpuri , received back of distribution transformer after increasing capacity from pit site to esc, mainpuri

CTN :45628848 Due date: 27 Jun, 202627 Jun, 2026 4.75 Lacs
Tender For repair & renovation work of type-v quarter at cbi, acb campus at betkuchi, guwahati.

CTN :45626062 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For dr.mvr rtpp- stg-iv-e&m const.chp-e&m-ii- procurement of battery charger spares- offer- req- reg - input contactor ac 70a,3pole,415v ac plus 1nc aux.(3tf477), coil voltage 415v ac. 220/240/380/415 v 20.5/22/35/38 kw 27/30/46/50 hp iec 60947 is 13947 vde 660 make, siemens, capacitor ac 10 mfd/440vac . make- tibcon, thyristor/scr module skkt57b16e 55a 1600piv , make semikron, filter capacitor ,3300 mfd/350 vdc,surge 385 vdc , cap. tolrance plus or minus 20% ,operating temp -40c to 85c, iec 60384-4- 2016, make-alcon electronics pvt ltd., trip relay 12v, 3c/o ,5a ,bis is16463- 2016 , make- pla relays, capacitor, 2.5 mfd, voltage- 440v ac, make- tibcon, power contactor 63a , coil volatge- 415 vac, input contactor ac 63a,3pole,415v ac plus 1nc, aux.(3tf477) make, siemens, 220/240/380/415 v 20.5/22/35/38 kw 27/30/46/50 hp, iec 60947 is 13947 vde 660, blockind diode float , 70a,800v threading type anode (70hmr120). iec-60747-9- 2007 make- ruttonsha, filter capacitor,pg-6di ,4700 mfd/350 vdc,surge 385 vdc , cap. tolrance plus or minus 20% ,operating temp -40c to 85c, iec 60384-4- 2016 ,make-alcon electronics pvt ltd., fuse link, hrc, tia 16 amp ,415v , 80ka make- siemens, eaton bussmen series., fuse link tia type 32a ,a2 gg 415v ac , 80ka , make- c and s ,siemens, eaton bussmen series etc. is/iec 60269., ac voltmeter fuse 2a/32a ns type make- siemens,eaton bussmann series, lawson etc.bis is 16463- 2016., control fuse 6a/32a , ns type make- siemens,eaton bussmann series, lawson etc.bis is 16463- 2016 ., over load relay,5a,3c/o,18v make- pla relays, fuse link,cylindrical,type- hf,size- 14x51,32a bis is 16463- 2016 make- l and t., bottle for transformer oil sampling,2000ml,stainless steel. make- apt engineering works/monarch controls/aone scientific/top syringe manufacturing company etc., thyristor protection fuse,type/model- fr22gg specifications- 32a gg 690v ac 80ka bs88-2 iec 60269-2 make- bussmann series.
 Loading, Please wait...

Connect us via What's Up