Get complete information related to latest Lt Metal Part Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lt Metal Part Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lt Metal Part Tenders.
Tender For supply of right auxiliary interlock to emd part no.40091011 to pl no. 18140397. note: item suitable for use with contactor.. a.c. 3 pole, 325 amp to emd p/n. 40037904 [ warranty period: 30 months after th e date of delivery ]
Tender For supply of auxiliary contactor pantograph and vcb (pos no 130.1, 136.4) specn/ drg no:- clw spe c no clw/es/3/0040 alt-c with latest alteration, abb document no- hbtb 585683r1127 (offer of only those firms will be considered which has quoted latest drawing /specification/ alteration/ revision) [ warranty period: 30 months after the date of delivery ]
Tender For supply of hog a & b control auxiliary contactor (s2k8 & s2k9) with 24v dc coil, aux 3 no+ 4 nc. mate rial shall conforming rdso specification no. rdso/ pe/ spec/ tl/0195-2019 (rev-0) or latest. accepted make s : as per rdso specification no. rdso/ pe/ spec/ tl/0195-2019 (rev-0) pg.24, s.no. 15 - schneider part no. ca3kn31bd+la1kn04 or siemens part no. 3rh21221bb40+ 3rh2911-1ha22 or abb part no. nfzb44ert- 21 or l&t part no. mo0 dc or c&s electric part no. tca3dn22bd+ ta1dn22. material shall be procured fro m above said oem or authorized dealers with authorization letter of said oem only. supplier shall submit o em test certificate along with material. [ warranty period: 30 months after the date of delivery ]
Tender For supply of vacuum contactor 400 amps 3.3kv part no. ht200 , vacuum contactor closing coil 110v dc part no. ht203 , vacuum contactor holding coil 110v dc part no. ht204 , p. t. 40va part no. ht206 , auxiliary contactor part no. ht208 , resin cast pt 300va 3.3kv by 110v 3 phase part no. 350 or ht350 , e.l.unit complete without transformer part no. 800 or ht800 , power hrc fuse part no. ht1500 , brass cable gland complete with c.i clamp stud part no. 1600 or ht1600 , static type relay part no. ht900a , pilot relay 12dc part no. ht2200 , contactor part no. ht200a , diode by255 for vacuum contactor part no. ht200c , vacuum contactor rectifier bridge part no. ht201 , copper terminal bar part no. 701 or ht701 , terminal chamber for i by c t by g o by g and partition part no. 1600b or ht1600b , auxiliary switch for vacuum contactor 2no and 2nc part no. ht205 , resin cast part no. ht300 , ht control fuse 3.3kv 2amps part no. ht400 , resin cast moulded cbct part no. ht500 , resin cast part no. ht650 , dmc moulded 3.3kv insulator for power fuse part no. ht700 , hrc fuse base and carrier for control part no. ht1200 , hrc fuse part no. ht1201 , lamp holder part no. ht1400 , cable box complete w o gland for i by c t by g oby g and partition part no. 1600a or ht1600a , isolator handle on off with axel bush part no. 1501 or ht1501 , copper bus bar 400 amps set of 3 part no. ht101 , relay part no. ht900e , isolator limit switch part no. ht1700 , isolator part no. ht100b , 72 sq mm ammeter suppressed scale part no. 1000 or ht1000 , ammeter selector switch part no. 1001 or ht1001 , single phase preventer cup 20 part no. 2001 or ht2001 , 72 sq mm voltmeter 0 to 5 kv by 110 voltpart no. 1100 or ht1100 , resin cast part no. ht600 , push button with element for start stop test and reset part no. 1300 or ht1300 //bid details 2 / 29
Tender For supply of auxiliary switch assembly for c-118 contactor for wag7 locos to clw's spec. no. clw/e s/c-15/d. [ warranty period: 30 months after the date of delivery ]
Tender For supply of various spare parts for psi department - input contactor, add on aux contact, dvr contactor, auxiliary contactor, air break, in open execution, auxiliary contactor, auxiliary contactor, auxiliary contactor, air break, in open execution, auxiliary contactor with surge suppressor, auxiliary contactor with surge varistors, open/close contactor, dc supply supvn aux contactor, aux contactor, dc contactor, dc contactor, dc contactor, aux contactor, dc contactor, aux contactor, aux. contactor, add on contact block, add on contact block, add on contact block, auxiliary contactor, auxiliary contactor, fcbcs i/p contactor, dvr contactor, dvr contactor, bch i/p contactors, bch i/p contactors, contactor, contactor, contactor, dcdb incomer contactor, winding temperature indicator, oil temperature indicator, winding temperature indicator, oil temperature indicator, remote wti/oti, for wdg temp,oil temp, for tap position, winding temperature, fire alarm, mpcb, time delay relay, rtcc supply, indication supply, out of step, trip circuit supervision, trafo fault relay, dcdb earth fault relay, transformer protection relay, mtr,86, relay, auxiliary relay, aux relay, 8 step apfc relay with rs-485 port, led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (22.5mm) (iec/is 60947-5-1), led indication lamp (10mm), 25 mm ring, door limit switch, 2.5sqmm, open/close interlock release emergency stop p.b, release emergency stop p.b, push button with spring return, push button actuator red mushroom head nonilluminated, for alarm cancellation, raise/lower command/lamp test push button, overload relay, c/o relay, bridge rectifier, counter, smps, mechnical interlock (3 lock+2 key), i/p voltmeter, o/p voltmeter, digital voltmeter with builtin selector switch, dc voltmeter, digital voltmeter with inbuilt selecter switch, digital voltmeter with inbuilt selecter switch, anolog voltmeter, o/p ammeter, battery ammeter, digital ameter with builtin selector switch size 96x96sqmm, 3 , ammeter with inbuilt selector switch., dc voltage monitoring relay, voltage monitor relay with phase sequence, voltage monitoring relay nominal, voltage monitoring relay (phase & voltage control), fcbc o/p relay, fcbc o/p relay, fcbc boost relay, fcbc voltage sensing relay, relay (air breaker auxiliary contactor relay) (relay with base), multi function meter ctr-1/5a,cl-1 with comm.port rs-485nominal voltage, 415v ac aux voltage-230v ac/ 125-250v having following parameter v, a, f, pf, power, kwh, with tod etc., multifuction meter with builtin selector switch, 230vac aux supply;96sqmm, rs-485portcl-1, digital kwh meter., digital kwh meter., digital kwh meter., on delay timer, on delay timer, on delay timer, on delay timer, hrc fuse (rectifier fuse), bs type hrc bolted/closed slot, fuse base bs type hrc bolted /off settag, bs type hrc bolted/closed slot, control circuit fuse, control fuse with base, control fuse with base, fuse link, control hbc fuse, control hbc fuse base, input fuses, rectifier fuses, capacitor fuse, fuse for lighting, motor fuse, local/remote switch, breaker control switch (trip neutral close), motor switch, auto/manual selector switch, cooler auto/manual selector, door switch, local/remote, breaker cotrol switch with key (spring return), auto/manual selector switch, auto/manual selector switch, auto/main selector switch, local/remote selector switch, vcb auxiliary switch, local/remote switch, interlock switch with mech. lock, auxialry switch, charger on/off switch- cam type front panel mounting knob handle, ac i/p voltage selector switch, breaker control switch, miniature circuit breaker, miniature cir
Tender For supply of hog a & b control auxiliary contactor (s2k8 & s2k9) with 24v dc coil, aux 3 no+ 4 nc. mat erial shall conforming rdso specification no. rdso/ pe/ spec/ tl/0195-2019 (rev-0) or latest. accepted ma kes : as per bom of rdso specification no. rdso/ pe/ spec/ tl/0195-2019 (rev-0) page no.-24, s.no. 15 - schneider part no. ca3kn31bd+la1kn04 or siemens part no. 3rh21221bb40+ 3rh2911-1ha22 or abb part no. nfzb44ert-21 or l&t part no. mo0 dc or c&s electric part no. tca3dn22fd++ta1dn22 tca3d n22bd +ta1dn22. [ warranty period: 30 months after the date of delivery ]