Web Analytics Made Easy - StatCounter

Lt Panel Repair Tenders

Get complete information related to latest Lt Panel Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lt Panel Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lt Panel Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :42137097 Due date: 10 Oct, 202510 Oct, 2025 6.50 Lacs
Tender For providing, installation, testing and commissioning of lt control panel, voltage stabilizer and the allied works at tw cum ps chak shekhian in kathua.

Central Government/Public Sector

CTN :42140247 Due date: 23 Oct, 202523 Oct, 2025 45.00 Lacs
Tender For maint repairs replacement of lt over head line lt ug cable of lt distribution system including allied works in pocket b and lt control panel boards at different mes installation including allied works at jasai mil stn under ge a barmer

Corporations And Associations And Others

CTN :42125050 Due date: 08 Oct, 202508 Oct, 2025 18.97 Lacs
Tender For provision of air conditioning facilities at lt panel rooms, oxygen manifold room, fire control room etc. at mata gujri hospital, tilak nagar.

CTN :42136985 Due date: 23 Oct, 202523 Oct, 2025 3.00 Lacs
Tender For providing and fitting of 185amp lt protection control cum fault analysis panel to 120hp motor of pump unit no.1 with allied works and its electrification at lis ratti bhakta

CTN :42115954 Due date: 15 Oct, 202515 Oct, 2025 NA
Tender For recapitalization by way of provide and fitting parts of lt control panel for 2 x 20 hp motors, ats 2no. along with other electromechanical devices at lis bindala mang.

corporations/Associations/Others

CTN :41891779 Due date: 03 Oct, 202503 Oct, 2025 934
Tender For supply and installation of 85kw ongrid solar rooftop power plant and 5 years maintenance at swm site, yadapura road, arsikere cmc limit - bos-balance of system & integrating with dashboard for real-time energy production monitoring, grid & battery performance tracking, iot-based remote monitoring & control, smart alerts & predictive maintenance, historical data & performance analytics,web & mobile dashboard access, three phase bidirectional smart energy meter and escom energy meter approval charges, application charges, agreement making and synchronization, installation of aluminum rails, solar panels and inverters. wiring from panels to dcdb, dcdb to inverter, inverter to acdb, acdb to lt panel, panel to panel loop earthing, dc earthing, ac earthing and light ninga rrest or flatlaying. and comprehesive maintenance for 5 years, aluminumrailstructure,longrailorshortrailstructurefor panel mounting. end clamps and mid clamps mounting structure using spring nut and all enboltfasteners.rivetingforeach rail with epdm layer for water leak protection., provision and installation of hot-dip galvanized earthing flats, fabricated from is 2062 grade steel with 80 100 micron zinc coating for long-term corrosion resistance. the conductor arrangement includes standard 25x6 mm gi earth flat (center folded) as the main earth conductor, along with 25x3 mm gi flat as auxiliary earthing strip, deployed for interconnection of solar inverters, modules, and distribution panels to the common earthing network, design, supply, and installation of maintenance-free chemical earthing system comprising a 3-meter long, 17.2 mm dia copper-bonded electrode with 250-micron coating. the electrode is provided with backfill compound for enhanced soil conductivity and long-term stability, ensuring low-resistance grounding suitable for rooftop pv installations and associated electrical equipment protection., provision and installation of solar-grade flexible copper earthing conductor, made from high-conductivity copper (is 8130 1984 compliant) with uv-stabilized pvc insulation for outdoor durability. includes 1.1 kv, 1cx6 sq.mm green-yellow coded cable, deployed for module mounting structure and panel earthing to ensure reliable system grounding and enhanced safety in rooftop pv installations, provision and installation of solar-grade flexible copper earthing conductor manufactured from high-conductivity copper (is 8130 1984 compliant) with uv-stabilized pvc insulation. includes 1.1 kv, 1cx6 sq.mm green-yellow coded cable, deployed for module mounting structure and panel earthing to ensure reliable grounding and electrical safety in rooftop pv systems., provision and installation of solar grade flexible copper earthing conductor, manufactured from high-conductivity copper is 8130 1984 compliant, insulated with uv-stabilized pvc for long-term rooftop exposure. includes 1.1 kv, 1cx6 sq.mm green-yellow coded cable, specifically designated for inverter body earthing and safety bonding within the pv system, provision & installation of frls xlpe insulated 1.1 kv aluminum conductor h4 grade, stranded class-2 power cable, optimized for solar inverter to acdb interconnection. cable construction includes black extruded xlpe inner sheath is 5831 compliant, with galvanized steel armoring providing 90% coverage for enhanced mechanical protection, designed in accordance with is 1554/iec 60189. scope covers 4c x 25 sq.mm a2xfy cable routing and termination, integrated into rooftop photovoltaic ac distributio, custom-provision and installation of solar pv compliant dc cabling system comprising tuv-certified 1.5 kv electron-beam cross-linked xlpo insulated copper conductors with uv-resistant sheath. scope includes color-coded red and black 1cx4 sq.mm cables, optimized for rooftop photovoltaic string interconnections, supply and installation 8-in8-out dcdb1000vdc,ip65,iec certified, iot-compatible for remote monitoring voltage and current , ip 65 enclosur

corporations/Associations/Others

CTN :42111694 Due date: 15 Oct, 202515 Oct, 2025 NA
Tender For echp-i- painting of power and control junction boxes, street light poles, ss-iv lt switch gear panels, battery charger panels, power contactor panels, dc panels and fire alarms panel located in various location in red gate area.

Central Government/Public Sector

CTN :41770212 Due date: 06 Oct, 202506 Oct, 2025 48.00 Lacs
Tender For corrigendum : repairs maintenance to fire fighting system fire hydrants fire alarm systems control panels and lt panel lt cable and connected miscellaneous items at phase ii residential area under ge i r and d east bangalore

Central Government/Public Sector

CTN :41850418 Due date: 06 Oct, 202506 Oct, 2025 NA
Tender For corrigendum : special repair/ replacement of control/ lt panel, water supply network at zangli, niyari and chowkibal under the aor of ge 874 ews.

State Government

CTN :42074248 Due date: 30 Sep, 202530 Sep, 2025 NA
Tender For material supply for office building gnida- 33 kv pt for vcb resin cast, indoor, single phase, voltage transformer complete with built in hv fuse. ratio 33000/110v, , 33 kv epoxy resin cast ct 200/100/5+5a, class 0.5/5p10, burden 15 va. make savio industries. , 33 kv epoxy resin cast ct 50/100/5+5a, class 0.5/5p10, burden 15 va. make savio industries. , insulator 33 kv oil transformer , 33 kv epoxy resin cast indoor insulator , power bank 240 v/24 v for ht panel , 33 kv oil transformer silica gel , transformer oil , spound core paint , contractor 32 amp (make l&t) , overload 7 to 11 amp (make l&t) , 33 kv joint kit 3x185 sqmm (ht) , capacitor 25 kv annual repair (lt. panel) (make l&t) , core paint , tulip contact (33 kv vd-4 breaker abb) , closing coil (33 kv vd-4 breaker abb) , closing coil (lt. breaker) (make mitsubishi) , motor 24v (l.t. breaker) (make mitsubishi) , triping coil (33 kv vd-4 breaker abb) , master trip relay (h.t.) (make abb) , high-set idmt relay with 3 o/c+e/f, abb rej601 24v-240v ac/dc 5a rej601be446nb1nh , shunt trip coil 24 volt dc (make abb) , multi function meter-em 6400 , volt meter (make - schneider) , amp meter (make - schneider) , master trip relay (h.t.) 24 volt dc (make - c&s) , vaccum bottel suitable for 33 kv indoor type panel vd4 (make-abb) , pole for 33 kv indoor type panel abb vd4 make , spout 33 kv vcb make - abb indoor type panel for incomer (6 nos.) , spout 33 kv vcb make - abb indoor type panel for outgoing (6 nos.) , vcb charging motor (make - abb) , indication light , 110 volt r, y, b , 240 volt r,g , breaker control switch h.t. & l.t. (make t&c)
 Loading, Please wait...

Connect us via What's Up