Web Analytics Made Easy - StatCounter

Lt Panels Tenders

Get complete information related to latest Lt Panels Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lt Panels Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lt Panels Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45741797 Due date: 08 Jul, 202608 Jul, 2026 NA
Tender For supply of spares components to earth leakage detector of anuvidyuth make. the set consists: 1. meter module (main card, insulation tester and panel meter), 2. channel module (channel card fittedwith accessories), 3. main module for add-on units, 4. channel card, 5. mains cards, 6. cable cards, 7. mother board, 8. panel meters, 9. transformer xr-273-3, 10. transformer xr-243-n1, 11. transformer xr-355, 12. terminal strips channel/mains, 13. display card, 14. test leads redx2+green, 15. frc connector for meter reading, 16. relay 4 change over, 17. multi turn pot 20k (mt), 18. reset switch mpu-2, 19. dc buzzer, 20. rotary switch, 21. euro9 connector 32 pin, 22. euro connector 48 pin and 23. 1m potentio meter for main module. firms offer: make/model: anu vidyut [ warranty period: 30 months after the date of delivery ] ]

Central Government / Public Sector

CTN :45516989 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For corrigendum : supply of 9040m26d81 spares of 23-k-101( khds rgc) - heater panel

State Government

CTN :45739217 Due date: 15 Jul, 202615 Jul, 2026 NA
Tender For supply of abb make ph sensor , abb make ph analyzer , abb make conductivity analyzer , conductivity sensor , annual spares kit , tubing kit exc pump tubes , power supply board panel mount ac

corporations/Associations/Others

CTN :45495960 Due date: 08 Jul, 202608 Jul, 2026 NA
Tender For corrigendum : repairing and overhauling of various types of fans and replacement of different types of defective electrical panel spares installed at different building of malda medical college and hospital, malda

Central Government/Public Sector

CTN :45733897 Due date: 22 Jul, 202622 Jul, 2026 NA
Tender For repair/maintenance of lt distribution network lt panels and connected items at mil stn dappar under age(i) dappar

Central Government/Public Sector

CTN :45425477 Due date: 06 Jul, 202606 Jul, 2026 47.30 Lacs
Tender For corrigendum : special repair /replacement of over head acsr conductor with ug cable lt panels and connected items of stn hq , hq cwe dinjan and hq cce area under ge dinjan

Central Government/Public Sector

CTN :45733975 Due date: 21 Jul, 202621 Jul, 2026 10.00 Lacs
Tender For repair and maint of lt external elect works, lt panels at hq 10 sector rr, 29 rr at pattan grn under age (i) cif (k)

Central Government/Public Sector

CTN :45726505 Due date: 20 Jul, 202620 Jul, 2026 45.00 Lacs
Tender For repair/maintenance of diesel generator set with central panel and other connected items at zone 5 and 1(a,b,c) zone 1, 3 (a and b), zone 2 and zone 4 under ge (s) tezpur - maint and servicing of dg set 320-400 kva conopy type with amf panel (if installed ), through authorise service agency of oem , including replacment of defective/wornout parts with new spares such as filters, gaskets, v belts, engine oil, coolant for radiator rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner , including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water and cleaning of pol tank and radiator etc complete all as specified and directed.note:- 1. spares required for above maint will be measured and paid separately under relevent items of schedule. 2. all breakdown calls should be attended., all as per item no-1 above but for dg set of capacity 180-250 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 125-160 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 40-100 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 10-35 kva complete all as specified and directed, supply only fuel filter for 300-400 kva dg set, complete all as specified and directed, supply only fuel filter for 125-250 kva dg set,complete all as specified and directed complete all as specified and directed, supply only fuel filter for 10-100 kva dg set,complete all as specified and directed, supply only lub oil filter for 300-400 kva dg set,complete all as specified and directed, supply only lub oil filter for 125-250 kva dg set,complete all as specified and directed, supply only lub oil filter for 10-100 kva dg set,complete all as specified and directed, supply only air cleaner filter ( inner and outer ) for 300-400 kva dg set, complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 125-250 kva dg set,complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 10-100 kva dg set,complete all as specified and directed, supply only bypass filter for 300-400 kva dg set, complete all as specified and directed, supply only bypass filter for 125-250 kva dg set,complete all as specified and directed, supply only bypass filter for 10-100 kva dg set,complete all as specified and directed, supply only v belt for 300-400 kva dg set, complete all as specified and directed, supply only v belt for 125-250 kva dg set, complete all as specified and directed, supply only v belt for 10-100 kva dg set, complete all as specified and directed, supply only coolant for radiators complete all as specified and directed., supply only engine oil multi grade 15w40 complete all as specified and directed., s & f in repair display control panel ( base card) for 10 to 100 kva dg set complete all as specified and directed ., s & f in repair display control panel (base card) for 125 to 250 kva dg set complete all as specified and directed., s & f in repair display control panel (base card) for 300 to 400 kva dg set complete all as specified and directed., s & f in repair fuel actuator with o ring for 300 to 400 kva dg set complete all as specified and directed., s & f in repair key switch for 10 to 400kva dg set complete all as specified and directed., s & f in repair coolant temperature sensor (coolent control safety) for 10 to 400kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 10 to 100 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 125 to 250 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 300 to 400kva dg set complete all as specified and directed., s & f in rep

Central Government/Public Sector

CTN :45714895 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For special repairs to lt panels and connected items at pyro, pinaka, nag mixture building, magazine area and ap building in hemrl, pune - taking out old serviceable/unserviceable lt panel/capacitor panel of any description or capacity keeping aside in safe custody for schedule of credit complete all as specified and directed, supply, fixing and commissioning of cpri approved factory made lt cubicle panel board outdoor type conforming to is/iec-61439-1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick crca sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opeing and lcoking arrangement, degree of protection ip 56, 415 volts, 3 phase, 4 wire, 50 hz having aluminium bus bar of capacity 1200 amps tpn duly colour coded and for neutral supported with dmc/smc insulator colour coded with heat shrinkable sleeve having short circuit current with minimum 65 ka for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of cts of metering, selector switches for voltmeter and ammeter, set of three led type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in pcc 1:2:4 type b1, ms channels 50 x50 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:-incoming: (a) acb adjustable type with thermal magnetic release 4 pole, 800a, 415v, 50 ka, 50 hz - 01 no. outgoing: (b) mccb 4p, 400 amps, 36 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 03 nos, (c) mccb 4p, 125 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (d) panel mounted type digital multifunctional energy meter a, v,z, kw, pf t operated, lt 3 phase, 4 wire inclding ct ratio 200/5 - 04 nos, (e) control mcb c curve, sp, 6 to 32a, 10ka, c curve - 02 nos, (f) led phase indicator (r,y & b) - 01 set. (pyro sub stn), supply, fixing and commissioning of cpri approved factory made lt cubicle panel board outdoor type conforming to is/iec-61439-1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick crca sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opeing and lcoking arrangement, degree of protection ip 56, 415 volts, 3 phase, 4 wire, 50 hz having aluminium bus bar of capacity 1200 amps tpn duly colour coded and for neutral supported with dmc/smc insulator colour coded with heat shrinkable sleeve having short circuit current with minimum 65 ka for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of cts of metering, selector switches for voltmeter and ammeter, set of three led type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in pcc 1:2:4 type b1, ms channels 50 x50 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:-incoming: (a) acb adjustable type with thermal magnetic release 4 pole, 800a, 415v, 50 ka, 50 hz - 01 no. outgoing: (b) mccb 4p, 400 amps, 36 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (c) mccb 4p, 315 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (d) mccb 4p, 250 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 02 nos (e) panel mounted type digital multifunctional energy meter a, v,z, kw, pf t operated, lt 3 phase, 4 wire inclding ct ratio 800/5 - 04 nos, (e) con

Central Government/Public Sector

CTN :45475151 Due date: 07 Jul, 202607 Jul, 2026 49.00 Lacs
Tender For corrigendum : repair/maint of lt ug cables, switch gears, bus bars, lt panels distribution systems, apfc panels etc and connected works in tech area af stn gwalior
 Loading, Please wait...

Connect us via What's Up