Get complete information related to latest Lt Pin Insulator Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lt Pin Insulator Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lt Pin Insulator Tenders.
Tender For corrigendum : supply of 4500 sets of stay set complete - supply of silicagel blue, 0.6kva ups, stay set complete( quote price for single unit only), silicagel blue 10 to 12mm, pole pit for 9.0m and 9.14 m psc/rcc / all metal poles (each pit) 1.25 x 0.6 x 1.83 mtr, ordinary soil, semi rocky soil, heavy rocky soil where blasting/ cheseling required [specific approval should be obtained from concerned ee], stay pit, in ordinary soil [0.95 x 0.6 x 1.2m], semi rocky soil, stay pit in heavy rocky soil where blasting/ cheseling reqiured [specific approval should be obtained from concerned ee], erection of poles & stays (including refilling of excavated earth), erection of 7.5m / 8.0m poles [rcc / psc], erection of 9.00m / 9.14m rcc / psc/rail pole, tubular pole and all metal poles, stay set, erection stay set complete, stay erection without rod and pit, replacement of stay rod only. (including stay pit excavation & refilling & erection), replacement of guy shackle only in existing stay, erection of line materials, fixing of lt 1 ph "x" arm, fixing of lt/ht ti fitting, fixing of lt 3 ph "x" arm, fixing of 3[1/2] v ` x arm, fixing of 4[1/2] v ` x arm, fixing of 5 v x arm, fixing of tapping channel / guarding "x" arm, providing of line spacers in lt lines 1 phase, providing of line spacers in lt lines 3 phase, erection of ab switch with pt insulator & jumpering complete, erection of centre rotating switch ab switch complete, fixing of ht pininsulator / strain disc, 11 kv pininsulator with pin, 11 kv strain disc / polymer disc with hardware, 22 kv pininsulator with pin, 22 kv strain disc / polymer disc with hardware, 33 kv pininsulator with pin, 33 kv pin strain disc/polymer disc with hardware, fixing of ltpininsulator with pin, lt shakle with hardware, fixing of aluminium knob, paving stringing and sagging of conductor including binding of pin and proper tight [including transport of condutor from road side to work spot] per run, upto 7/2.59 mm acsr, 7/2.50 aaac including pvc cable upto 25 sqmm, acsr 7/3.35mm & 7/ 3.15 aaac including pvc cable above 25 sqmm, acsr 7/4.09 mm, above 7/4.09 mm acsr & dog conductor, earthing wiring and connection including transporting of earth pipe and excavation of pit], transformer structure earthing 10ft depth - 3 nos of pipe through tubes, dp earthing including all works [double side earthing], erection of 4th earth pipe including earthing, earthing of poles, earth pit masonary work 3 nos earth pits or using 3 nos concrete tub., replacement of detoriated earth pipe per location, concreting with mixture 1:3:6 [including all materials]., mass concreting for centre support for 2 feet including all materials, mass concreting for pole0.6x0.6x1.25m.with coping, sleeve concreting for pole 0.6 m x 0.6m x 0.3 m with coping, sleeve concreting for stay set 0.3 m & 0.75 long, erection of distribution transformer structure complete, excavation of structure pole pits 0.9 x 0.9 x 1.83 mtr, transporting of pole to pit location 2 nos., erection of poles 2 nos, excavation of stay pit 4 nos, erection of stay set (4 sets), mass concreting (cement:sand:jelly supplied by the contractor) 2 nos., erection of 22 kv ab switch, ttransformer structure earthing 10ft depth - 3 nos of pipe through earth tubes, erection of top channel, bed channel [2 nos channel] erection, cross with stud for bed channel erection, erection of belting angle / hg fuse angle, erection of hg fuse set, erection of ht las with jumpering and earthing, erection of lt las with jumbering and earthing, erection of jumpering [ht side], transformer wiring in lt side including jumpering bus bar etc., erection lt open type fuse unit arrangement single, erection lt open type fuse unit arrangement double, painting of stru. complete excluding dt [two coat of red oxide] all metal parts(excluding cost of paint)., painting of stru. complete excluding dt [one coat alu paint, excluding cost of paint), colour washing of 2 numbers structure p
Tender For auction sale of others - scrap cond. m and p items old used and u.s electrically operated synchronized hyd. jack with power pack, capacity 15t, manufactured by navyug industries, new delhi & commissining on dt 18/06/2007. qty 01 set (in 1 set, power pack is included), m&p nos. m/c&w/ 93 ( a to e), 01 set = 05 nos + power pack, location bg workshop bhavnagar. "as is where is " basis. mode of delivery in set. custodian sse scrap bvp, delivery will be given after full payment. if required removal,dismantaling and transportation from place of installation to workshop main gate and there after shall be in the scope of purchase, the purchaser firm has to arrange necessary equipment/tools and dismantle the machine from its foundation without damaging railway property. loading by purchaser, fdp 50 days.
Tender For ghrssidc/e-t/2026-27/646 - electrical fabrication - a, la cross arm clamp for 7.5 mt rcc pole (gal v) - cee/e/523, sa cross arm clamp for 7.5 mt rcc pole (gal v) - gec/e/523, la cross arm clamp for 9 mt rcc pole (gal v) - gec/e/524, sa cross arm clamp for 9 mt rcc pole (gal v) - gec/e/524, la cross arm clamp for 105 lbs/yd rail pole (gal) - gec/e/723, sa cross arm clamp for 105 lbs/yd rail pole (gal) - gec/e/723, la cross arm clamp for 60 lbs/yd rail pole (gal) - cee/e/486, sa cross arm clamp for 60 lbs/yd rail pole (gal) - cee/e/486, la cross arm clamp for 90 lbs/yd rail pole (gal) - cee/e/515, sa cross arm clamp for 90 lbs/yd rail pole (gal) - cee/e/515, la stay clamp for 60 lbs/yd rail pole (gal) - cee/e/469, sa stay clamp for 60 lbs/yd rail pole (gal) - cee e 469, la stay clamp for 90 lbs/yd rail pole (gal) - cee/e/508, sa stay clamp for 90 lbs/yd rail pole (gal) - cee/e/508, la stay clamp for 7.5 mtrs rcc pole galvanised - cee e 523, sa stay clamp for 7.5 mtrs rcc pole galvanised - cee e 523, la stay clamp for 105 lbs/yd rail pole (gal) - cee e 723, sa stay clamp for 105 lbs/yd rail pole (gal) - cee e 723, la stay clamp for 9 mtrs rcc pole (gal v) - cee e 524, sa stay clamp for 9 mtrs rcc pole (gal v) - cee e 524, 11 kv v shaped cross arm (gal v) - cee e 408, 33 kv v shaped cross arm (gal v) - cee e 408, b type modified distribution box - cee e 386, a type street light meter box with clamps - cee e 386, stay set for 11 kv lt line - cee e 500, stay set for 33 kv line - cee e 500, turn buckle& eye bolt for 33 kv line - cee e 513, turn buckle& eye bolt for 11 kv line -cee e 466, cast iron packing piece 90 lb for rail pole - cee e 514, top insulators fitting for rcc pole - cee e 506, 4 pin angle type cross arm - cee e 702, 4 pin channel type cross arm - cee e703, 2 pin angle type cross arm - cee e704, 2 pin channel type cross arm - cee e 705, earthing pipe - cee e 467, sa cross arm clamp for ht/lt line on 11 mt rcc pole made of 50 x 10 flat (g) - cee e 711, la cross arm clamp for ht/lt line on 11 mt rcc pole made of 50 x 10 flat (g) - cee e 711, sa stay clamp for ht/lt line on 11 mt rcc pole made of 50 x 10 flat (g) - cee e 711, la stay clamp for ht/lt line on 11 mt rcc pole made of 50 x 10 flat (g) - cee e 711, sa bottom clamps for fixing street light fixtures for 7.5/9mtrs rcc pole galvanised 25 mm pipe - cee e 12, sa top bottom clamps for fixing street light fixtures for 7.5 mts rcc pole galvanised 25 mm pipe - cee e 12, la top clamps for fixing street light fixtures for 7.5/9 mts rcc pole (gal v) 40 mm pipe - cee e 612a, sa top clamps for fixing street light fixtures for 7.5 rcc pole - cee e 612a, gi nut and bolts in various sizes electro galvanised, gi pins for ltpininsulator, gi pins for 11kv pininsulator, gi pins for 33kv pininsulator, gi bent pipe of nominal base 25 mm, 1 mts long for tube light fixture - cee/e 618, gi bent pipe of nominal base 25 mm, 1.5 mts long for hpsv lamps - cee/e 593a, b type modified distribution box with mccb and kit kat fuses as per cees specifications / drawings, metal parts for shackle insulators as per cees specifications, gi bent pipe of nominal base bar 40mm x 3 mts long (medium class) the pipe shaft should conform to is : 1239 (part i) 1973 as amended upto date - ee/ii/21/2009, hot dip galvanised earthing strips of size 30x160x5mm, hot dip galvanised earthing strips of size 100 x 360 x 3mm, g.i bent pipe nominal bore 40 mm ce/e xi for hpsv lamps - cee/e 593a, metal parts for disc insulator as per department 4 bolted. as per department specification & drawing - 60/4/va/cee/tech/2019-20/1282, metal parts for disc insulator 3 bolted - 60/4/va/cee/tech/2019-20/1282, kit kat fuse 100 amps, kit kat fuse 200 amps, kit kat fuses 300 amps, kit kat fuse 400 amps, tinned copper fuse wire of various sizes, aluminium crimping lugs 25 sq.mm, aluminium crimping lugs 35 sq.mm, aluminium crimping lugs 50 sq.mm, aluminium crimping lugs 70 sq.mm, aluminium crimping lugs 95 sq.mm, aluminiu
Tender For design, manufacturing, supply and installation of 100 ton capacity hydraulc scrap baling machine(manual) with 30 hp electric motor powered hydraulic power pack as perenclosed specification. [ warranty period: 24 months after the date of delivery ]