Web Analytics Made Easy - StatCounter

Lt Shackle Tenders

Get complete information related to latest Lt Shackle Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lt Shackle Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lt Shackle Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45726591 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee

Central Government/Public Sector

CTN :45726596 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif

CTN :45165928 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For corrigendum : the supply of g i bolt for lt shackle insulator as per dgvcl specifications

corporations/Associations/Others

CTN :45289693 Due date: 02 Jul, 202602 Jul, 2026 1.74 Lacs
Tender For corrigendum : supply of lt shackle insulator

CTN :45631927 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For supply of stay clamp for pcc pole , x-arm holding clamp for pcc pole. , f-clamp for pcc pole , stay insulator , lt shackle insulator , m. s. nut & bolt (for fixing material of sl. no. 1, 2&3)

CTN :45318928 Due date: 01 Jul, 202601 Jul, 2026 11.91 Lacs
Tender For corrigendum : supply of gi pin for 22 kv pin insulator , metal parts for lt shackle insulator , gi pin for lt pin insulator

CTN :45601875 Due date: 03 Jul, 202603 Jul, 2026 NA
Tender For stay clamp 5 , 11 kv stay insulator , lt shackle insulator , holding clamp , lt clamp , 11 kv f clamp , ms nut and bolt of size

corporations/Associations/Others

CTN :45277777 Due date: 02 Jul, 202602 Jul, 2026 1.74 Lacs
Tender For corrigendum : supply of lt shackle insulator

Central Government/Public Sector

CTN :45354486 Due date: 25 Jun, 202625 Jun, 2026 7.92 Lacs
Tender For corrigendum : supply of 11 kv ht polymer pin insulator , 11 kv ht polymer disc insulator , 415 volt lt pin insulator , 415 volt lt shackle insulator , 11 kv ht lightning arrester

State Government

CTN :45587069 Due date: 02 Jul, 202602 Jul, 2026 20.00 Lacs
Tender For supply of safe carriage of 8.5 m long pcc , safe carriage of 11 m long pcc , safe carriage of 9 m long stp , safe carriage of 11 and 13 m long stp , safe carriage of line material , safe carriage of xlpe cable , safe carriage of 11 kv ct pt pole mounting , safe carriage of 10 and 16 kva tf , safe carriage of 25 and 63 kva tf , safe carriage of 100 kva tf , etection of 8.5 m long pcc single support , etection of 9 m long stp single support , etection of 11 and 13 m long stp single support , etection of 11 m long pcc single support , etection of 8.5 m long pcc double pole section pole , etection of 11 m long pcc double pole section pole , etection of 11 and 13 m long stp double pole with tpmo etc , laying sagging of dog conductor , laying sagging of acsr weasel conductor , laying sagging of lt xlpe cable , laying sagging of 11 kv xlpe cable , laying sagging of ab cable , fixing of stay rod , fixing of 3 phase distribution box , erection of 11 kv ct pt pole mounting unit , installation of 11 kv pilfer metering cubical , providing and fixing of suspension clamp , providing and fixing of nut bolts off size , providing and fixing of lt shackle insulator , providing and fixing of dead end clamp , providing and fixing of stone pad , providing and fixing of danger board , providing and fixing of barbed wire , providing and fixing of number plate , fixing of joint kit outdoor , fixing of joint kit indoor , mounting of 10 and 16 kva tf , mounting of 25 and 63 kva tf , mounting of 100 kva tf , earthing of pcc pole stp dt , new guarding of ht lines with gi wire , carriage of acsr dog weseal conductor scrap , carriage of line material scrap , carriage of st pole scrap * /bid number : gem/2026/b/7664537 + /dated: 17-06-2026 ' ' / bid document 1 / 30