Web Analytics Made Easy - StatCounter

Lt Switch Gear Repair Tenders

Get complete information related to latest Lt Switch Gear Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lt Switch Gear Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lt Switch Gear Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

corporations/Associations/Others

CTN :43210251 Due date: 31 Dec, 202531 Dec, 2025 NA
Tender For ttps es circle em ii external cleaning and attending minor maintenance works in electrical equipments such as power transformers rectifier transformer electronic control panels lt switchgear panel cable trays etc in esp i ii iii for the period f

corporations/Associations/Others

CTN :43210294 Due date: 31 Dec, 202531 Dec, 2025 NA
Tender For ttps es circle em ii weekly cleaning, terminal tightness checking of ht lt motors lt switchgear panel contactor panels and external cleaning of electrical equipments cable tray cleaning works of ahp stage ii foph 1 dm plant clwph and ash dyke area

corporations/Associations/Others

CTN :43211060 Due date: 31 Dec, 202531 Dec, 2025 NA
Tender For ttps es circle em i complete preventive maintenance of lt breakers ht breakers ht panels lt panels lt modules in 6 6 kv switchgear control room generator transformers uats usts ssts floor cleaning in 6 6kv switchgear control room 230kv indoor switchy

State Government

CTN :43207126 Due date: 02 Jan, 202602 Jan, 2026 NA
Tender For annual maintenance contract for all ht/lt switchgear of 1x500mw, htps, korba west.

State Government

CTN :43204028 Due date: 26 Dec, 202526 Dec, 2025 1.04 Lacs
Tender For supply of various types of auxiliary relays for ht/lt switchgear panels and local control panels of 500mw unit at utps, gsecl.(emd-6)

corporations/Associations/Others

CTN :43205127 Due date: 31 Dec, 202531 Dec, 2025 NA
Tender For ttps es circle em ii weekly cleaning terminal tightness checking of ht lt motors ht lt switchgear panels ht lt breakers modules contactor panels and external cleaning of electrical equipments cable trays control room cleaning works at ahp stage 1

State Government

CTN :43204486 Due date: 23 Dec, 202523 Dec, 2025 NA
Tender For supply of multi function meter required in ht and lt switchgear for the units of stage - ii/btps

CTN :42917720 Due date: 23 Dec, 202523 Dec, 2025 33.66 Lacs
Tender For corrigendum : supply of spares of ge make lt switchgear installed in electrical and chp circle at stps,suratgarh - supply items:-, shunt trip assy.with coil-220vdc for acb m610 type,1000a and m16 type,1600a.cat.no.pga0100874, moving contact block for acb m610 type,1000a and m16 type,1600a. cat.no pga0100040, top fixed contacts for acbm610type,1000aand m16type,1600a.cat.no pga0100271, trip roller with link for acb m610type,1000a and m16type,1600a. cat.nopga0130224, trip prop for acb m-610type,1000a.cat.nopga0100117, lt disconnect moving for acb m-610,1000a & m-16,1600a,cat.no.pga0100171, lt disconnect fixed for acb m-610,1000a&m-16,1600a,cat.no.pga0100172, spring limit switch assy. mws for acb m-610,1000a & m-16,1600a,cat.no.pga0140911, spring limit switch for acb m-610,1000a&m-16,1600a,cat.no.pga0120373, closing coil accesso. for acb m-610,1000a & m-16,1600a,cat.no.pga0120676, aux. switch mounting plate for acb m-610,1000a & m-16, 1600a,cat.no.pga1100423, shunt trip coil 220v dc for acb m-610, 1000a & m-16,1600a, cat.no.pga0100039, shunt trip assy. with coil 220v dc for acb m-3032,3200a,cat.no.pga0100874, spring limit switch for mwspga0140911, model m3032,3200amp., spring release ass.220v dc for acb m-3032,3200a,cat.no.pga0100879, shunt trip coil assy. with coil typea0100874, modelm610, top fixed contacts typepga0100285, modal3032, bottom fix contact pga0100283, model m3032,3200, aux. switch for acb m-610,1000a & m-16,1600a, cat.no.pga8010001, lt disconnector fixed pga0100172, model m3032, 3200amp., cmm-125 switch fuse unit125a, 3pole,415v without fuse, cmm-200 switch fuse unit200a, 3pole, 415v without fuse, cmm-400 switch fuse unit400a, 3pole, 415v without fuse, moving contact carriage for cmm-125,125a, 3pole, moving contact carriage for cmm-200, 200a, 3pole, caliper contact for cmm-125, 200, 250& 400, dowel pin for cmm-125 to 400

CTN :43140429 Due date: 25 Dec, 202525 Dec, 2025 34.90 Lacs
Tender For - arc of electrical material. - electrical work :, providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket/pole. fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with uv stabilized pc (uv stablization report submitted for uv cover ) /toughened glass cover and secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm/ wt and potted driver & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driver efficiency >85% ,thd(i) 10% humidity 10% to 90% rh working temp -5c to 45c . driver current 750ma. the luminaire shall be bis certified and trade mark certified. life expectancy equal or more than 50000 burning hrs with minimum 70% lumen maintened , cri >70 and cct 5700k +355k. surge protection shall be min 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark/name engraved/embossing on die cast housing to allow traceability/authenticity. fixture shall be as per is 10322 complianced.oem must have its own in house nabl lab setup for all testing facilities for led fixtures. (lm79/lm80) certificate/ report with liable warranty of product/accessories from oem shall be submitted. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr . led street light fixture with minimum lumen output 5600 lm, supplying and drawing of xlpe insulated lt aerial bunched aluminium conductor cable confirming to is 14255/1995 and is 398 (pt-4)/ 1994 and as per discom specs. on existing cross arms through i hook with all necessary t&p required including binding and twisting etc. complete in all respect as required. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr . 1 x 25 sq. mm. + 1x25 sq. mm. (insulated), supply and fixing of 11 kv pin insulator confirming to is:731:1971 with latest ammendment on existing bracket including all accessories like ms forged hot dipped gi pin confirming to is 2486(part-i)/1993 & is:2486 (part-ii)/1989 with latest amendment, and as per latest discom specs. etc. as required. all as per pre approved by engineer in-charge.for additional technical parameters of product / work refer annexure a attached with this bsr, sitc of ip-42 and general construction confirming to is:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)thickness of crca sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel. the panel having pe foam/ neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only. all joints / interconnections of copper bus bar shall be dully tinned . c

Central Government/Public Sector

CTN :42585018 Due date: 19 Dec, 202519 Dec, 2025 NA
Tender For corrigendum : open tender for lt switchgear for gsecl wtps boiler repair and maintenance project
 Loading, Please wait...

Connect us via What's Up