Web Analytics Made Easy - StatCounter

Lube Oil Cooler Repair Tenders

Get complete information related to latest Lube Oil Cooler Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lube Oil Cooler Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lube Oil Cooler Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45739358 Due date: 21 Jul, 202621 Jul, 2026 NA
Tender For supply of electrical wire 1mm , electrical wire 1.5mm , electrical wire 4mm , electrical wire 2.5mm , electrical wire 6mm , electrical wire 16mm , induction cooker , desert cooler , gas pipe

Central Government/Public Sector

CTN :45726591 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee

Central Government/Public Sector

CTN :45726596 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif

CTN :45715657 Due date: 15 Jul, 202615 Jul, 2026 17.38 Lacs
Tender For tender for supply of erection and fabrication work b c c - juice/water scale ke weight channel bed mein se gale/kamzor channel ko kaatkar hatana. poorvanusar naya banakar lagana evam trial dena. , juice weighing scale ke filling tank ke rods ki kamzor/gali guides ko naya banakar lagana. , juice. maceration water evam final molasses ke weighing scale tank ke gale/kamzor bottom cone ko kaatkar purane anusar naya bottom cone lagana va poorn trial dena. , juice weighing system ke measured juice receiving tank ki gali/kamzor bottom evam side plates ko kaatkar hatana evam nirdeshanusar purani/nai plate lagakar leak.proof trial dena. , raw juice pump par lage catcher ko kaatkar hatana tatha naya catcher fabricate kar yathasthan lagakar samast connection poorv ki bhanti karna evam leak.proof trial dena. , pan. quad body evam vapour line juice heaters ki hydraulic testing ke liye inlet evam outlet ke vapour pipes mein cutting karke plate ke blind weld karna tatha hydraulic uparant blind kaatkar hatana evam vapour pipe ko punah andar va bahar se leak.proof weld karna. , semi kestner. vapour cell. quad body juice heater. vapour line juice heater ke condensate bottles tatha syrup receiving bottles ke cells ko kaatkar ceiling baffle plate ke kamzor hisse. bottom plate ke kamzor hisse athva cell ke kamzor hisse ko badalkar condensate bottles/syrup receiving bottles ki vanchhit marammat kar jal bharav parikshan dena. , juice heater mein lage ayatakaar juice entry box ko dismantle karna. gale/kamzor charon nipples badalna. double beat valves ki fitting hetu dono flanges lagana. box ki marammat kar box fit karna evam double beat valve fit karke leak.proof parikshan dena. , sabhi juice heaters ki gali hui sampoorn partition plate ko kaatkar bahar nikalna va nai 8/10 mm plate lagakar gili hui ring ko leak.proof welding karna tatha lagi hui tubes ko bachakar santoshjanak trial dena. , juice heaters mein dono taraf partition plate ki kamzor m.s. strip ko dismantle karna. kate face par grinding kar nai 25 mm x 5 mm ki m.s. strip banakar lagana evam rubber fit karna. , juice sulphiter ke recovery tower ke gale/kamzor bottom cone ko kaatkar 10/12 mm moti m.s. plate se sample anusar naya cone fabricate kar yathasthan fit kar leak.proof welding karna. , juice sulphiter ke base ke charon side ke gale/kamzor horizontal beams ki vanchhit strengthening hetu unke andar 12 mm moti plate lagakar majbooti pradan karna. , juice/syrup sulphiter ke kamzor bottom cones evam top cones ko dismantle kar sample anusar naya banakar fit karna. tatha andar va bahar se leak.proof welding kar santoshjanak jal bharav evam trial dena. , syrup sulphiter ke tower ki gali/kamzor baffle plates/jaliyon ko bahar nikalna. vanchhit marammat kar yathasthan fit kar leak.proof trial dena. , syrup pump se syrup sulphiter tak dono pumps ki delivery ki dono lines ko neeche utarkar garam karke. bhali bhanti safai karna. gali hui pipe line badalkar valve. bend. nipple ityadi lagakar punah lines ko fit karna evam leak.proof trial dena. , syrup/juice sulphiter ke upar lage recovery tower ko utarkar gali shell ko nirdeshanusar nai/purani plate se shell taiyar kar fit karna evam tower ko punah yathasthan lagakar leak.proof trial dena. , juice/syrup sulphiter/clarifier ke kamzor shell ke kamzor bhag ko kaatkar hatana. nirdeshanusar nai/purani 10/12 mm plate se banakar yathasthan lagakar andar va bahar se leak.proof welding kar trial dena. , sulphur bhatti (juice/syrup) ke gale/kamzor secondary gas cooler ko kaatkar hatana. 10/12 mm moti plate se purane ke anusar naya cooler fabricate kar yathasthan fit kar samast connection poorv ki bhanti kar leak.proof gas trial dena. , sulphur bhatti station par juice/syrup hetu sthapit sulphur bhattiyon ke gas coolers ke gale/kamzor cooling pipes ko kaatkar hatana. purane anusar naye pipes taiyar kar poorv ki bhanti fit kar leak.proof trial dena. , sulphur bhattiyon ke gale gas headers ko kaatkar hatana. purane anusar naye headers taiyar kar lagana. , sulphu

CTN :45478155 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For corrigendum : cs/rmo/2026/2089-90/ac/washing - items, ac compressor 1-5 ton, ac compressor 2 ton, ac outdoor gas bal, ac indore fan motor, ac outdoor fan motor, ac condensers, ac gas charging, ac condenser outdoor mesh, connector ac, ac sensor indore, ac running capacitor, ac service charge, water cooler fan motor, water cooler compressor, water cooler condenser, water cooler mash, water cooler riley, water cooler over load, water cooler running capacitor, water cooler service charge, water cooler gas filling charge, washing machine spine timer, washing machine wash timer, washing machine wash motor, washing machine spine motor, washing machine bello, washing machine gear box, washing machine capacitor, washing machine service charge, refrigerator compressor, refrigerator rile, refrigerator overload, refrigerator thermometer, refrigerator senseor, refrigerator wall, refrigerator fan motor, refrigerator bimetal, refrigerator time, refrigerator pcv, refrigerator fuse, refrigerator door swath, refrigerator gas charge, refrigerator service charge, ac pcv, ac stand for spilit ac, ac stand for window ac, copper pipe for spilit ac per feet, copper pipe for window ac per feet, spilit and window ac remote

corporations/Associations/Others

CTN :45712936 Due date: 13 Jul, 202613 Jul, 2026 19.20 Lacs
Tender For running maintenance of plc system - running preventive and breakdown maintenance of plc control system with electrical drives all control and instrumentation system of ash handling , replacement new erection of impulse line , replacement new erection of instrument fitting adopter nut tails elbow connector etc , overhauling b 501 and b 601 ss cock valve , overhauling repairing of junction boxes , servicing recalibration erection of fuzi yokogava rosemount etc transmitters , overhauling and recalibration new erection of digital indicators , overhauling and recalibration erection of flow meter conductivity meter , complete overhauling erection of level switches , replacement of pressure switch gauge vibration switch , removal testing erection commissioning calibration of temp gauges switches thermocouple , replacement erection overhauling cleaning of union isolating valveforged body valve , blowing of tapping points of different pressure transmitters switches , fabrication repairing of instruments plateform , laying patrolling of instrumentation cable , servicing and maintenance of air conditioner , cleaning of control room plc system , repairing of ups , service replacement of faulty butterfly valves along with act , servicing replacement of faulty diaphragm type valves , changing spindle gland of root valves , cleaning blowing by air of impulse lines , attend leakage from steam water air line , replace gauges switches of pressure temp , testing caliberation of pressure gauges , testing calibration of pressure switches , testing calibration of temp gauges , testing calibration of temp switches , replacement of thermocouples , cleaning servicing of terminal block in compressor house swas system , changing of ss root valves , servicing of 10mm hp lp 3way manifold valves , replace of 10mm hp lp 3way mfold valves , removal choking replace of impulse line , erection replacement of pvc armored compensate cable , replacement of universal digital indicator , servicing replacement of faulty 4way valve with actuator , replacement remounting of smps 24 v dc , dismantling replacement of combination timerof compressor , servicing of sampling cooler dhx18 sco2 , servicing of sampling cooler dhx12 sco2 , servicing of sampling cooler dhx06 sco1 , miscellaneous mechanical febrication , maintenance of actuator of butterfly valve , maintenance and upkeep of terminal box of motor of actuators in cw pump , maintenance re erection of butterfly valve actuator motor , revisioning and upkeep of marp dcs panel , revisioning testing of various type of switches of local control panel , maintenance revisioning upkeep and testing of 415 v power supply module , maintenance upkeep and repair of junction box of butterfly valve , servicing of mov motors actuators and limit switch assembly , checking cleaning and cable dressing mov motor , overhauling cleaning reconditioning of various size batteries , load test once in six months for various size battery of ups installed for 5x200mw , replacement of damaged switches mcb in acdb panel , cleaning painting of the wooden battery stands , maintenance of window type split type ac , gas charging of ac , rewinding of burnt fan motor

corporations/Associations/Others

CTN :45345524 Due date: 06 Jul, 202606 Jul, 2026 10.97 Lacs
Tender For corrigendum : supply of oh of main steam line valve v2 6 , oh of steam by pass valve v2 27,15, and v2 7 , oh of es 3,4,5,6 and 7 , oh of v2 -82-84 and v2-81-a to 81c , oh of hd-21, hd-29, hd-30 and hd-31 , oh of nrv of h.p. heater and feed pump , oh of group protection valve of hph , oh of dw-4, 37,38,39,40,41 and ca 5 , oh of cst makeup valve v6 60 , oh of as-48 valve , oh of nrv of extraction line es-8 , oh of suction valve of bfp , oh condensate wtr throw off valve to condenser , oh throw off valve to cond and steam isolating of lph2 , oh of steam isolating valve of lph 3, 4 , oh of safety valve of aux prds or deaerator , oh of safety valve of h.p. heater , oh of safety valve of l.p. heater. , oh of safety valve of cbd tank. , oh of safety valve of flange or stud heatng , oh of safety valve of warm up line. , overhauling of actutator of as 48 valve , oh of actr feed line valvev2 81 or v2 82 or v2 83 or v2 84 , oh of actr of v2 7 or v2 15 or v2 27 , oh of actr drip line valve and ext line valve , oh of actr valve connected to condenser , oh of actr cst make valve , oh of actr of msv l and r , oh of actr of steam isolating valve to lph2 to 4 , oh of actr steam throw off valve to condenser , cut or weld or repl of hp valve 15 to 50mm , cut or weld or repl of hp valve 51 to 100mm , cut or weld or repl of h p valve 101 to 150mm , oh of butterfly valve of condenser , oh of dea and fst with internal painting , repair or replacement of broken hanger , tightening of loose hangers , cut or weld or repl of l.p. valve 15 to 50mm , cut or weld or repl of l.p. valve 51 to 100mm , cut or weld or joint of h.p. pipe 15 to 50mm , cut or weld or joint of h.p. pipe 51 to 100mm , cut or weld or joint of h.p. pipe 101 to 150mm , cut or weld or joint of h.p. pipe 151 to 300mm , lift or straight aprds hdr by cutting weldding , o h of lph 1a , 1b , o h of lph 2 3 and 4 , oh and attend flange leakage of gc i or ii , clean of turbine oil or h2 gas cooler str , repl of damaged sp. valve v2 38 , repl of damaged special valve v2 27 , oh of turbine oil coolers , oh of main ejectors of turbine , oh of h.p. heater , oh of lcv 3to15pcv-5, 14,16,17,tcv 8 , repl bend of lp drip connected to drip pump or condenser , cut damaged bend of hph drip cont to dea , cut weld or repl of h.p. valve 151 to 300mm , blank of crh line for ht and normalizing , oh of h.p. valve nrv in h.p. line , oh of l.p. valve nrv , oh of energy absorber of bfp , oh of dss of aux. prds.

CTN :45380508 Due date: 10 Jul, 202610 Jul, 2026 NA
Tender For corrigendum : supply of 7426618000 o ring , es6031d-7426902000 shim , es6031d-7427117000 flexmast conn gm10006-038 38 od , es6031d-7427903000 sleeve spring , es6031d- 7427904000 key for damper , es6031d-7427905000 damping bush , es6031d-7430511000 thermostat element , es6031d-7432024000 37 pin female connector-for p , es6031d-7432412000 set of oil seal 19x30x7 for aroto g15sp ffp , es6031d- 7432423000 sperical roller bearing , es6031d- 7432427000 oil seal retainer , es6031d-7432433000 packing at both end , es6031d-7432436000 valve seat , es6031d-7432641000 bush dia 22 26 x 14 , es6031d- 7438675000 set of full flow elements fm s01 lo filter , es6031d-7438676000 set of diversion element for fms01 lo filter , es6031d-7438678000 set of gaskets for lub oil filter , es6031d-7446602000 o ring d 8 21a7 l 12cm , es6031d-7508411000 gasket 138x138x2mm , es6031d-7526695000 cyclam seal set , es6031d-7526712000 lub oil engine inlet connection , es6031d-7526719000 barring gear air outlet connect , es6031d-7527805000 stud , es6031d- 7529531000 spring pack new , es6031d-7529536000 spacers , es6031d-7530404000 flexmaster conn pipe- 60 3mm od , es6031d-7531011000 set of o ring for lub oil cooler , es6031d-7531208000 round joint , es6031d-7532001000 pyrometric duct , es6031d- 7533207000 flexmaster conn 64 for pipe 114 3mm o d nbr , es6031d-7534105000 joint , es6031d-7534114000 joint , es6031d-7534609000 adoptor exhaust gas out let , es6031d-7535202000 conduit fr brg temp tgs , es6031d-7550311000 thermostat element 74 82 deg c , es6031d-7550312000 sealkit 74 82 deg c , es6031d- 7550411000 thermostat element 35 42 deg c , es6031d-7550412000 seal kit 35 42 deg c , es6031d- 7550513000 spare part kit for fw sw heat exchanger , es6031d-7551901000 air cooler outlet conn hose , es6031d-7551903000 fuel pump inlet conn , es6031d-7551904000 fuel leak conn from ss valve , es6031d-7551905000 level switch overflow conn , es6031d-7551906000 fuel filter inlet conn , es6031d-7551907000 fuel feed pump discharge conn , es6031d-7551910000 ss valve air inlet conn , es6031d-7551911000 starting air conn inlet , es6031d-7551917000 connection for pre lub oil suction , es6031d-7551918000 connection for pre lub oil pump , es6031d-7551919000 connection for oil vapour escape , es6031d-7551920000 connection for oil vapour escape , es6031d-7551921000 engine inlet pressure connection , es6031d-7551922000 oil drain connection , es6031d-7551925000 fresh water pump suction connection , es6031d-7551926000 fresh water engine outlet connection , es6031d- 7551927000 fresh water air cooler inlet connection , es6031d-7551928000 intake pressure connection , es6031d-7551929000 fresh water pre heating inlet connection , es6031d-7551941000 by pass valve closing control connection , es6031d- 7551942000 governor speed setting air inlet connection , es6031d-7551943000 rack position limiter , es6031d-7591016000 magnetic pick up for turbocharger , ek3010b-7527121000 joint , ek3010b- 7527122000 joint , ek3010b-7536414000 joint , ek3010b-7926739000 rectangular gasket , ek3010b- 5000310030 screw set , ek3010b-5000312030 screw //bid details 2 / 101 set , ek3010b-7428510000 o ring an33 60c7 , ek3010b- 7445620000 main bearing assly , ek3010b-7529535000 link , ek3010b-8002195000 con rod brg pair , ek3010b-8019225000 piston ring top , es6031d- 5000320050 set screw m20x2 5x50 8 8 , es6031d- 5050140000 circlip external , es6031d-5050160000 circlip external 60mm , es6031d-5050811000 copper washer 14x18 , es6031d-5054005012 spring dowel pin , es6031d-7426105000 magnetic pick up , es6031d- 7426513000 o ring , es6031d-7426619000 o ring ms 295 13 245 60c7 viton , es6031d-7426620000 o ring viton an 75 60c7 , es6031d-7428022000 joint , es6031d-7430629000 o ring i 438x4 60c7 , es6031d- 7430638000 gasket , es6031d-7430642000 gasket , es6031d-7437206000 gasket , es6031d-7508412000 o ring , es6031d-7533510000 joint air cooler , es6031d- 7552527000 temp switch tcm96p 40deg c decreasing , ek3010b-7430677000 set of gas

CTN :45688894 Due date: 16 Jul, 202616 Jul, 2026 NA
Tender For supply of supply of precleaner for air cleaner , connection , o ring for moatti lub oil filter , injector nozzle assembly , zinc rod , 1/8 bsp drain cock , plate covering , valve grinding paste (901702) , joint , lub.oil pressure sensor with switch , set bolt - m12x1.75x50 - 8.8 , set bolt-m16x2x50 - 8.8 , set screw m10x1.5x35-8.8 , stud , socket head grub screw - m10x10 , slotted c sunk head screw -m6x , circlip , banjo bolt-m14x1.5 , washer spring , clip jubilee for strainer , connection piece to turbocharger , flexible hose , temp.indicator 0 50 degc. , glass fuse 300ma size 5x20 fast blow , set of 10 , fuse 1a , iso1 electrodistributor , 24vdc , solenoid return , fuse 2a , fuse 6a , se card , m.e bearings scanner exhaust gas temp , on release safety card rgm card , logic unit and , programmable output(0-20) , indicating lamp-red , with lens , holder and lamp , indicating lamp-white with lens , holder and lamp , fuse cartridge 4a(am)10x38 , watershed connection , plunger barrel assembly (dia 25 mod) , o ring 4 x22.5 perbunan , o ring , o ring (for liner collar) , temp.switch(model ti-250-s)95deg 10m capilla , pressure transmitter , pr. transmitter 0-10 bar , gfl bolts , low lub oil sump level switch , set bolt -m20x2.5x120-8.8 , set scrw -m20x2.5x40-8.8 , stud m12x1.75x45-8.8 , self locking nut , allen screw , screw , socket head cap screw-m12x25-12.9 , socket head cap screw -12x40-12.9 , socket head cap screw-m12x55-12.9 , circlip , circlip external -60mm , banjo bolt - m22x1.5 , washer copper , copper washer , copper washer(33x39) , mech dir pin , spring dowel pin , spring dowel , lock washer pair , plain bearing with bearing bush , thrust ring , locating ring , ring nut , intermediate ring , sealing disc , contact no , pressure gauge 0-4bar dial 4 bourden ss3 , analog indicator 72x72.0-4bar i p4-20m , pressure transmitter , range 0-6bar , pressure switch , set at2.0b , pf-3p4-w-bb-1x00-21b-10b-db-n-v.t , solenoid valve nc 24vdc(y94 , y97 , y142.y143 , y) , high signal selector (or module) , solenoid valve no.24 vdc (y198) , safety stop , pressure guage with glycerine , i/p-0-10 bar , pressure transmitter 0-4 bar 24vdc o/p-4-20 ma , pressure transmitter 10 bar 24vdc o/p-4-20 ma , pressure guage with glycerine , i/p-0-6 bar , selector plate (opening 1 , 3 , 5) , pressure transmitter 6 bar 24vdc o/p-4-20 ma , pneumatic distributor (7/1 , 7/2 , 7/3) fuel rack , pressure transmitter 40 bar 24v dc , pneumatic distributor (8/1 , 8/2 , 8/3 , 8/4) stop , pressure regulator (5) , on/off switch , 2 pole , off delay timer 0.2-300sec.+socket , converter module(t452 , t458)charging airtemp.f.w.temp.(0-100) , supply card , ae 24/24 , sleeve nt-hh-pn10-dn100 , damper key , spring pack(new) , o ring 8.2x680.6 (nitrile) , o ring , o ring , bush(32307) , bush(32301) , signal isolator 4-20 ma/4-20ma loop powered , bearing temp measure card (mtp card) , bearing temp alarm card (aip card) , regr. safeties temp. card (rsp card) , on release safety icm1 card , frequency divider for governor speed sensor , a.b.b t/c magnetic speed sen , solenoid valve cnomo dia-1.6 , 24 vdc , regulator for fw temp. , 24vdc , i/p-rtd , o/p-4-20 ma , green head for push button , blue head for push button , on delay relay 24v dc , threshold module , rgm card , frequency divider-turbo speed , cable (engine speed measure) , pneumatic switch for local/remote operation , selector plate (solid) , selector seal , sub base seal , pilot push in type , fresh water air cooler inlet connection , fresh water pre heating inlet connection , fuel rack indicator , pressure gauge 0-6 bars , pr. switch 1.2bar min. , pr. switch , 4140-c-k-1-e-22-aa0 , 4.1b , pr switch type 4140c-19 bar , pressure transmitter p5r-6bar-4-20-1/2-pe , pressure transmitter p5r 0-40 bar , mss module 0-150 deg(convertor) , temp switch tcm96p 40deg c decreasing , temp switch tcm96r 90deg c increasing , temp switch tcm96r 95deg c increasing , pressure transducer 0-10 bars , mss module 0-100deg.c 4-20 temp con

State Government

CTN :45695947 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For procurement of water coolers and desert coolers and other items for the various sites under ae(e and m) - iii in ac-66. (re-invite) - supply of high speed desert cooler, 3 speed control, floor mount type, up to 90 litre tank capacity, having auto swing, 230 volt. make : bajaj, orient, crompton, supply of stainless steel water cooler of 80 litre capacity, cooling water near 40 l/hr capacity, having dual tap dispensing system, powered by r134a refrigerant and a 2.5 amp system, copper cooling coils. make: blue star/usha/voltas, supply of stainless steel water cooler of 20 litre capacity, cooling water near 15 -20 l/hr capacity, having dual tap dispensing system, powered by r134a refrigerant , copper cooling coils. make: blue star/ usha/ voltas, supply of 1.5 ton 5 star inverter window ac, copper condensing coils, 2 way swing system, working on r32 refrigerant gas, cover up to 150 sq feet area, working on 230 volts with remote control. make: hitachi/ voltas/o general/panasonic/any djb approved make., supply of 1.5 ton 5 star smart inverter split ac, energy saving, working on r32 refrigerant gas, cover up to 150 sq feet area working on 230 volts with remote control. make : hitachi/ lg/voltas / any djb approved make.
 Loading, Please wait...

Connect us via What's Up