Get complete information related to latest Lubricating Oil Sale Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lubricating Oil Sale Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lubricating Oil Sale Tenders.
Tender For supply of brake buster with master cylinder , brake pipe line master cylinder to bs pump , brake shoe rear both side complete set , hand brake cable rh , hand brake cable lh , hand brake cable front , rear road spring bush complete both side , shackle pin rear both side , road spring bolt rear , u bolt , nut , rear both side shock absorber assy , front both side shock absorber assy , both side upper arm bush 4 nos , anti role bar balancing rod both side , anti role bar balancing rod bush , damper pad both side front , torsion bar adjusting nut and bolt , centre bearing rubber bush , u j cross , lower coloum assy , front crank timing oil seal , timing oil seal , timing belt , front left axle assy with dust boot , front right axle assy with dust boot , tube oil seal both side front axle , pin shaft , left side roller bearing tube axle , right side needle bearing tube axle , thrust washer axle shaft , packing 4 by 4 , synthetic bush small , synthetic bush big , synthetic packing upper and lower , air filter , split pin , nut bolt size no 12 , assy vacuum pump decor , bulb 1141 , bulb 67 , windshield water reserve pipe , 4 pin relay big type starter heavy duty , 4 pin relay small , starting relay , 4 pin relay big , fuse 15 or 20 normal size 4 plus 4 , wheel sensor front , wheel sensor rear , fog light bulb 12 volt , wiper blade , rubber biding complete set , rear lift side door lock inner and outer complete set + /bid number : gem/2025/b/6350565 , /dated: 16-06-2025 ( ( / bid document 1 / 41
Tender For corrigendum : empanelment of agencies for supply of laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoridemeter: ph/ise benchtop meter with electrode stable, universal power adapter, literature, pc cable, meter test certificate electrode: ionplus fluoride and nitrate combination ion selective electrode, 1m cable, waterproof bnc benchtop ion meter (ise) along with fluoride, nitrate #electrode range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 relative accuracy 0.002 calibration points up to 5 calibration editing yes #mv/ rmv orp range 2500.0 mv resolution 0.1 relative accuracy 0.2 mv or 0.05 % of reading whichever is greater eh orp mode yes ise range 0 to 19999 resolution up to 3 significant digits relative accuracy 0.2 mv or 0.05 % of reading whichever is greater units ppm, m, mg/l, %, ppb, none calibration points up to 5 calibration editing yes calibration features timed end point, linear point to point, non-linear selectable auto-blank, low concentration range stability #temperature range -5 to 105 c, 23 to 221 f resolution 0.1 relative accuracy 0.1 offset calibration 1-point datalogging memory 2000 with time and date stamp log function manual, ready (include auto-read ), timed log edit delete individual points, group of points or all inputs ph electrode bnc, reference pin atc probe 8-pin mini-din #output rs232, usb power ac adapter included universal, 100-240 vac battery power optional 4 aas battery life 800 hrs, fluoride electrode of ion metersame make that of the ion meter, manifold filtration assembly* wide range of pumps and filtration flasks * high quality components * easily exchangeable elements *maintenance-free * low noise * added filters for enhanced pump longevity * filtration base with silicon stopper, cap & aluminium clamp connecting silicon tube technical specification for filtration flask set # high-pressure resistant tube # fiberglass filter membranes (47mm / 0.1 m) # ptfe disc filter #normal liquid filtration * specification for filtration glass set #suction bottle capacity(ml) 1000 ml # filter diameter(mm) 47/50 mm # * specification for filter flask * material: statinless steel 304, capacity: 300 ml (100 ml each) [ unit should consist of 3 flask so that 3 sample can be filtered simultanelously without any issue] # effective filtration area(cm2) = 9.6 cm2, outlet connector(mm) = 8 mm * specification for vaccum flask: #flow rate of the pump(l/min) = 17 l/minultimate vacuum(mbar) = 150 mbar # oil free, maintainance free, built in thermal protection to shut off when over heated., auto cut heater for distill water plant so that when water level decreases the heater is switch off automatically, voltage stabilizer capacity- 3 kva servo stabilizer 5 star rating, heating mantle (single station) should have digital energy regulator with multiple step power regulation automatic spill detection and saftey shutdown in built precision temperature control technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 420 degree celcius. accuracy: plus minus 1.0 degree celcius, power consumption : 150 w, heating mantle (combined unit) material of construction heating block: made with grade epoxy painted chemical resistant coating, aluminum block with 6 thermo wells for processing 6 different samples at a time. #racks: ss 316 # glassware: teflon coated # temperature range ambient + 10 deg c to 450 deg c # stability of temperature better than 0.5 deg c # controller consist of digital read out of temperature and time with 4 programmable ramps for each method. # number of programmable methods 20 numbers. # heating powers 1000w # heating position minimum 6 position # digestion time range -1 to 999 minutes # the system should have facility of acoustic signal at the end of completion of cycle to notify the operator. # the thermal digestion unit should have high thermal homogeneity # the setup should have small f
Tender For corrigendum : procurement of spares for prabhu make flp vcb 400a - coil for shunt trip spring release, part no.flpvcb 017 , auxilary transformer for control circuit, part no.flpvcb 023 , earth leakage relay, part no.flpvcb 024 , idmtl relay 2 oc and 1 ef with instantan, part no.flpvcb 026b , auxillary contc 3no 1nc110v coil, part no.flpvcb 028 , hrc fuse base 20a for control, part no.flpvcb 030 , epoxy resing moulded 1phase i 3.3 kv, part no.flpvcb 034 , pt fuse 3.3 kv, part no.flpvcb 035 , 72 sq mm voltmeter 0-5 kv ptr 3.3kv 110v, part no.flpvcb 037 , dmc moulded copper terminal 400a,3.3kv, part no.flpvcb 045 , h.t hex bolt for terminal chamber cover,part no.flpvcb 055 , h.t hex bolt for cablle box size m10 x 2,part no.flpvcb 056 , throughgoin g copper busbar 630a set of 3, part no.flpvcb 058 , h.t hex bolt for main lid and isolator lid, part no.flpvcb 053 , insulated cable 120sqmm trminl to incom, part no.flpvcb 070 , insulated cable 120sqmm outgong to term, part no.flpvcb 071 , shunt trip assembly with coil, part no.flpvcb 004 , solenoid operted spring release assy wi, part no.flpvcb 005 , copper net terminal, part no.flpvcb 007 , copper top terminal, part no.flpvcb 008 , copper bottom terminal, part no.flpvcb 009 , epoxy cast drive insualtor for vi, part no.flpvcb 011 , auxillary switch, part no.flpvcb 013 , 1 set spring for catch machnism for vcb, part no.flpvcb 014 , 1 set spring for drive machnism, part no.flpvcb 015 , 1 set spring for tripping drive insulotar, part no.flpvcb 016 , isolator 3.3 kv 400a complete, part no.flpvcb 018 , fibre glass link for isolator, part no.flpvcb 021 , epoxy molded cor balance transformer 3.3, part no.flpvcb 025 , magnetite ol relay comp, part no.flpvcb 026 , solid state overload and short circuit rel, part no.flpvcb 026a , under voltage relay with time delay, part no.flpvcb 027 , hrc fuse link for control, part no.flpvcb 031 , epoxy resin moulded c.t. for ammeter, part no.flpvcb 032 , epoxy resin cast c.t. for short circuit, part no.flpvcb 033 , 72 sq mm ammeter ct operated, part no.flpvcb 036 , brass actuator for push button, part no.flpvcb 038 , limit switch, part no.flpvcb 040 , led lamp holder with lamp vacuum circut, part no.flpvcb 043 , jones plug 18 pin, part no.flpvcb 044 , dmc mouldled auxillary terminal, part no.flpvcb 046 , brass gland complete with stud and nut, part no.flpvcb 052 , dashpot oil for ol relay 50ml, part no.flpvcb 059 , vacuum interrupter 400a, part no.flpvcb 006 , diode based rectifier complete, part no.flpvcb 029 , micro switch for push button element, part no.flpvcb 039 , h.t hex bolt for side lid and terminal ch, part no.flpvcb 054 , m.s meter fixing plate fitted with 01 n, part no.flpvcb 057 , version, manual spring assisted type, part no.flpvcb 001
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - commercial; hvac, substation, switchyard, power house equipment, transformer oil filtration through high vacuum filter machine and providing of dry air generator at vari..
Tender For supply of (1) gas charging meter with low pressure(0-250 psi) and high pressure(0-500 psi) indicator s uitable for refrigerant r407c . (2) refrigerant charging hose b.p 3000 psi w.p 700 psi (3) vacuum pump % u2013 single stage, high pressure, %bc hp, 250ml oil capacity, 57 l/min flow rate, suitable for refrigerant r407c. (4) refrigerant 407c suitable for sidwal ,intec, kki make roof mounted cab ac fitted in electric loco motives. [ warranty period: 30 months after the date of delivery ]
Tender For custom bid for services - rpnc252027 support service for swing extruder vfd installation-shifting, foundation and installation of power transformer- 1. the power transformer is to be installed by construction of new transformer foundation, dismantling/modification of surface, providing chain link fencing on all other 4 sides, cleaning and refurbishment of bay area is in the scope of contractor only. all necessary manpower, tools & tackles, shifting machinery like hydra/crane etc shall be in the scope of contractor only. 2. shifting of power transformer of 7.2 mva onan from store to site, loading-unloading, erection, site storage are in scope of contractor. 3. the basic data sheet and ga drawing of the proposed transformer is attached in scope only. 4. the bidder if required must construct bay width, height and fire walls as per relevant is/iec/oisd standards and site conditions such that adequate clearances for maintenance shall be maintained. bidder to submit the plot plan of equipment layout of transformer layout along with the bid. the bidder shall carryout the site visit for assessment of the available installation space. the total length of the transformer bay should be such that the radiator can be accommodated on either side of transformer tank in the specified bay width. 5. all necessary earth pit provisions, & fire barriers/wall modifications, provision of new hvws water sprinklerbased firefighting system having suitable capacity for protection against the fire & explosion as per the design of supplied transformer and applicable standards & direction of eic. provision of all necessary fire protection system for transformers shall be in the scope of lstk contractor. 6. construction of oil drain facility of transformer as per is standard and hookup with existing burn oil pit. 7. the erection to be certified by contractor as per its recommended procedures which is to be submitted prior to erection. qap for erection and site commissioning shall also to be endorsed by contractor. 8. all kind of lifting, rigging work for loading-unloading, erection work including supply of hydra/ cranes, lifting rigging materials, manpower, tools and tackles as required are in scope of contractor. 9. all kind of skilled, semi-skilled, unskilled manpower as per itc of transformer requirement will be in the scope of contractor. 10. erection includes entire vacuum by proper capacity of vacuum pump, for not less than 48 hours, or more if required as per the instruction of engineer in charge. 11. first filling up of the transformer oil at site, its filtration, site testing oil sample, any refiltration required during final commissioning shall be in the scope of contractor including all tools, tackles and including oil filtration machines. oil may be supplied in drums, which should be properly sealed during transportation and storage. seal shall be verified and opened in front of iocl representative before filling in transformer. contractor should have enough storage capacity for handling oil. filling the oil from drums to the transformer through suitable capacity of high-quality filter machine and filtration of the same to get desired bdv &ppm as specified by engineer in charge and transformer manual. 12. contractor must replace all the gaskets by new ones if required by engineer in charge. 13. the contractor shall arrange nitrogen cylinder required at site for above work. 14. contractor must repaint the transformer tank with two coats of anti-rusting good finish ltbs grey shade 631 of is:5 by spray painting if required and as per the direction of engineer in charge..