Get complete information related to latest Luminaire Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Luminaire Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Luminaire Repair Tenders.
Tender For replacement of existing lv switchgears of cjp power house sub-station and gm yard sub-station, installation of new lv switchgear at dock cabin and central cabin, along with allied power supply network upgradation work of haldia dock complex, smpk.
Tender For supply of audio visual items and stage lighting system for new academic block at nit delhi d d -video extender with av over ip controlling transmitter upto 30 meter range , full hd video extender with av over ip controlling receiver upto 30 meter range , full hd hdmi video capture card with hdmi loop out and usb output , room controlling device , 10 inch wall mount touch controller , 8 chanel power sequencer , 8 chanel light sequencer , 16 port poe ethernet network switch , 24 port gigabit ethernet network switch , 42u floor mount rack , cat 6 utp ethernet cable per meter , 2 sq mm two core speaker cable per meter , 1 sq mm three core control cable per meter , 2 point 5 sq mm three core power cable per meter , 4 sq mm three core power cable per meter , other required connecting cables and required accessories as per requirement for auditorium setup , other electrifications works required to install av equipment in classrooms , front curtain , back curtain , frill , 50mm dia b class gi pipe , wings , stage peritoneum work , m s pipe ladders to be provided on sides of the stage , 200 watt led profile spot , 200w full power light source , led par 54pcs high brightness , 200watt plano convex spot light , 200 watt led fresnel light , 400w led blinder , 300w beam moving head , lighting console with internal flash drive , electrical panel made out of ms sheet painted in gray colour , dmx splitter with one dmx input and 6 buffered outputs , light point wiring from patch panel , 3 core dmx cable with sheathed housing on the cable , lighting clamp , installation charges for stage furnishing and lighting , state of the art active indoor led display with glue on board with led wall controller , 86 inch ultra hd interactive flat panel display , digital podium , ai based auto tracking ptz hybrid video conferencing camera , ceiling mount kit for vc camera , visualizer with dtd cabinet , set of two wireless handheld microphone with dual channel receiver , all in one audio digital signal processor with 8 input and 8 output , 450 watt dual channel amplifier , 100 watt wall mount speakers , ultra hd hdmi matrix swicther with 4 hdmi input and 4 hdmi output , video mixing device with 4 hdmi input and 1 hdmi output , hdmi capture card with usb and hdmi loopout , ultra hd hdmi extender over cat 6 tx rx set upto 50 meter range , ultra hd hdmi cable 15 meter , usb 3 point 0 booster cable 10 meter , cat6 ethernet cable meter , 9u floor mount rack , other required cables and accessories , state of the art active indoor led display with glue on board technology with led wall controller , 65 inch ultra hd interactive flat panel display , 300 watt dual channel amplifier with combine bridge output of 600 watt , ultra hd hdmi matrix switcher with 4 hdmi input and 4 hdmi output , hdmi capture card with usb and hdmi loop out , cat6 ethernet cable per meter , floor mount stand for 86 inch interactive display , micro pc or ops pc i5 8gb ram 512 gb ssd with keyboard and mouse , usb video conferencing camera , wireless conference speakerphone , 100 inch ultra hd interactive flat panel display , dtd cabinet with visual presenter , camc charges for 2nd year , camc charges for 3rd year , camc charges for 4th year , camc charges for 5th year , camc charges for 6th year
Tender For corrigendum : supply of vhf antenna installation and associated works at kalaburagi airport - antennae installation work , antennae pole clamping work , laying of rf cable , flexible pipe , n type male rf connectors , n type female rf coaxial surge protectors , rf connector ntype male with 3 flexible mtr length , dc connector power strip industrial rack 24inch , dc power cable with 3 pin type connector female. , installation as per the scope of work
Tender For survey investigation, design, supply, installation, testing and commissioning of tank filling scheme consisting of construction of intake channel, forebay, jack well cum pump house, power supply including terminal bay, transmission line, electrical substation, rising main, distribution network, delivery chamber, gravity main network, various types of valves, receiving chambers, staff quarters, surge protection system for filling of 22 tanks in kambadal hosur and surrounding villages by lifting 0.19 tmc of water from bhadra river near gonibeedu village of bhadravathi taluk, shimoga district including operation and maintenance for a period of 5 years after successful completion of work for kambadal hosur tank filling scheme on turn-key basis
Tender For corrigendum : work-a) replacement of 1x8mva, 66/11 kv power transformer by 1x20mva, 66/11 kv power transformer and providing additional 1x20mva, 66/11 kv power transformer at 66/11 kv belavadi sub-station in arakalagudu taluk, hassan district. work-b) replacement of 2x8mva, 66/11kv power transformers by 2x20mva, 66/11kv power transformers at 66/11kv somanahally sub-station, in holenarasipura taluk, hassan district. work-c) replacement of 1x6.3 mva & 1x8mva, 66/11kv power transformers by 2x20mva, 66/11kv power transformers at 66/11kv hallymysore sub-station, in holenarasipura taluk, hassan district. on partial turnkey basis, including supply of all materials/equipments and erection (including dismantling & civil works) of all materials/equipments, testing and commissioning
Tender For work related to maintenance of smooth power supply system and restoration of electrical system/material by attending to the break down in minimum period due to storm/storm (natural disaster) in the area of work of various 33/11 kv sub-stations under
Tender For diversion of overhead line due to advancement of coal dump and other electrical work for safe and smooth power supply in decco workshop socp muraidih amp colliery.
Tender For tender for supply of m soil investigation : : -obalisation of necessary eqpt and man power to the project site and dismantling of the same of completion of field work from the site , provision of two bore hole of 150 mm dia in any type of soil upto max 10 mtr or upto refusal n 100 whichever meet first conducting standard penetration test as per is 2131 1981 reaffirmed 2016 test shall be made at not more than 1 50 mtr interval or on change of strata whichever is less , conducting following lab test on bore collected soil sample i direct triaxial shear test ii grain distribution curves & pattern in bore holes iii bulk density iv natural moisture content v dry density vi water table vii specific gravity viii atterberg limit ix hydrometer analysis x liquid & plastic limit xi swelling index , collection of lab test data calculation of gross and net safe bearing capacity and preparation of report on minimum 80 gsm a4 size white paper duly spiral bound in quintuplet duly vetted by any iit nit vetting shall not be in the personal capacity of the professor for foundation report shall recommend type of foundation and sizes at different depths below ngl including size gross and net safe bearing capacity , i photographic record of geo exploration as well as testing shall also part of the report ii recommendation as regards possibility of liquefaction of soil in case of saturated or partially saturated loose uncompacted sandy soil iii swelling index and swelling pressure in respect of black cotton soil and its depth layer if any iv depth of gr water table gwt in peak mansoon lowest and peak summer highest after correlation of result with seasonal of water table in the station v recommendation for filling under floors vi rl of ground level foundation level with ref to a bm should invariably be mentioned in the soil investigation report