Get complete information related to latest Lvdt Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lvdt Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lvdt Tenders.
Tender For corrigendum : supply of spares for 02 nos float and boost chargers for 220 vdc and 48vdc battery bank at power house c c - 16a ammeter selector switch for main input current selection , 16a voltmeter selector switch for main input voltage selection , 10a tp ac 2 way without off auto or manual mode selection for float and boost chargers , 16a sp dc 2 way without off switch for float rectifier or load bus and boost rectifier or battery voltage selector switch , 16a sp ac 2 way without off auto c or o mode or manual boost mode selection for charger , 10a tp dc 2 way without off for boost charging of battery set 1 or 2 selection , 225a dc coil operated emergency contactor coil 220v dc auxi 1no , 185a dc coil operated contactor for boost charging battery set 1 coil 220v dc auxi 2 nc , 63a dp dc on or off switch for load isolation , 40a dc coil operated emergency contactor coil 48v dc auxi 1no , 65a dc coil operated contactor for boost charging battery set 1 coil 48v dc auxi 1 nc , filter capacitor for ripple suppression for float and boost chargers rating 100 v 2200 uf , dc to dc convertor 48v dc to 24 v dc 5 amps , 4 channel relay boards for contact multiplication of card mounted protection relays , electronic card module for avr and current limit for float charger auto and manual mode , electronic card module for avr and current limit for boost charger auto and manual mode , electronic card module for float and boost rectifier fuse fail and filter fuse fail , protection module for various fault detection and annunciation , blocking diode for float and boost charger rating 70a i avg piv 800 for fcb mode on k3 heat sink , 80 percent blocking diode stud type rating 70a i avg piv 800 on k3 heat sink , latching resistor for rectifier. 250 ohms 50 watts for float and boost chargers , 10k 1w potentiometer for auto or manual voltage adjust in float charger , 10k 1w potentiometer for auto or manual current adjust in boost charger , 2ph control transformer for power supply of avr cards prim 415 v sec 16 0 16 v ac 400ma , 3ph control transformer for synchronising of avr cards. pri 415 v sec 16 0 16 50ma , 3ph control transformer for ac u or v pri 415 v 3 phase sec 0 16 vac 1 phase 250 ma , 2 0fi control transformer for fan control supply prim 415 v 2 phase sec 190v ac 50va , scr stud type 70a with heatsink loose module only , diode free wheeling stud type 70a with heatsink loose module only , digital ac ammeter 48 x 96 sq mm class 1 ct ratio 25 or 1a auxiliary voltage 24v dc , digital ac voltmeter 48 x 96 sq. mm class 1 range 0 500v ac auxiliary voltage 24v dc , digital dc ammeter for float boost chargers and 80percentage cell tap 48 x 96 sq mm class 1 75mv dc with shunt auxiliary voltage 24v dc , digital dc voltmeter 48 x 96 sqmm class 1 range 75mv dc auxiliary voltage 24v dc , digital dc charge or discharge ammeter for battery 48 x 96 sq mm class 1 range 75mv with shunt auxi 24v dc , transportation charges for material
Tender For comprehensive operation and maintenance of the project mainly water treatment plant, different class, type and diameter pipes, pump houses, sumps, rcc esr, h.g.l.r, sluice valves, flow meters, non-return valve, pump, motor, capacitor, l.t. panels, l.t. cables and transformer installed at headwork and sub headwork. work includes replacement of spares for all equipment and maintenance of all civil structures and all electro-mechanical installation etc. complete. including submission of periodic mis reports on software. supply of potable water in accordance, maintaining residual chlorine, and all consumables. all type operations, preventive maintenance, overhauls and repair/ break down maintenance for civil / mechanical & electrical works. providing prescribednos. of qualified and experienced staff for overall management of o&m work as per detailed specification & obligatory requirement for 60months. excluding electric power, raw water cost, chlorine, pac and bleaching powderunder dabhoi regional water supply schemes of tal.-dabhoi, dist.- vadodara.
Tender For corrigendum : supply of actuator spares for mov d d -modbus card module 6r bips , local remote pcb bips , hand wheel maintenance kit iq 20 bips , hand wheel maintenance kit iq90 bips , resolver pcb iq20 bips , resolver pcb iq90 bips , torque transducer iq20 bips , main pcb card mark 2 bips , power transformer iq20 bips , power transformer iq90 bips , battery plug-metal module 1l bips , main pcb card rotork actuator , fcu card iq mark ii , module 4c rotork actuator iq10 20 f14 b4 , contactor assy rotork actuator k150f10e , oil seal kit rotork actuator k series , blue filter rotork actuator k series , red filter rotork actuator k series , switch mechanism wd1640 z00e rotork actua , motor assy rotork actuator k series , indication lamp set rotork actuator k se
Tender For supply of purchase of spares for 220v battery chargers installed at tld 4 power house kalijhora : : -rfi card as per ts , drop resistance card as per ts , snubber card snb01 as per ts , control transformer 2988a as per ts , power supply transformer 4083a as per ts , contactor rc as per ts
Tender For supply of procurement of spares prabhu make flp lt ht starter dp and geb d d ? g? g - contactor complete 400 amps. 3. 3kv, part no. ht-200 , vacuum contactor rectifier bridge, part no. ht-201 , bottle for vacuum contactor 3. 3kv, 400 amps, part no. ht-202 , vacuum contactor closing coil 110v dc, part no. ht-203 , vacuum contactor holding coil 110v dc, part no. ht-204 , auxiliary switch for vacuum contactor 2no 2 nc, part no. ht-205 , p. t. 40va 0-8-12v 0-110v, part no. ht-206 , auxilary contactor 3 no 1 nc 110v ac, part no. ht-208 , resin cast p. t. 750va 3. 3kv 110 volts single phase, part no. ht-300 , h. t control fuse 3. 3kv, 2 amps, part no. ht400 , copper busbar 400amps set of three, part no. ht-101 , resin cast moulded c. t. for o l 3. 3kv, part no. ht-600 , dmc moulded 3. 3kv insulator for power fuse, part no. ht700 , push button with element for start, stop, test and reset, part no. ht--1300 , lamp holder with lamp for starter, part no. ht-1400 , brass cable gland complete with c. i clamp, stud , part no. ht-1600 , s t idmtl o c and s c r with time leg o l setting - 50 percent to 200 percent and s c setting 400 percent to 1600percent of flc, part no. ht-900a , e. l unit complete without transformer, part no. ht-800 , dmc moulded copper terminal 400a, 3. 3kv , part no. flp vcb 045 , isolator 100 amps reversing, part no. fs- 2 002 , air break contactor 40amps upto 20hp 550v starter, part no. fs- 2 003c , air break contactor 63amps upto 30hp 550v starter, part no. fs- 2 003e , auxiliary transformer 80va pri-500 525 550v sec-0-8-12, 0-110v, part no. fs- 2 004c , dmc terminal for i c ,t g,o g and partition 100 amps, part no. fs- 2 008 , dmc auxilary terminal, part fs2 009 , 3 pole magnetic o l relay type direct acting, part fs- 2 010 , direct acting thermal overload relay upto 30hp starter, part no. fs-2 010a , 65 sq mm ammeter ct operated, part no. fs-2 011 , 65 sq mm ammeter direct acting, part no. fs-2 011a , ct for ammeter, part no. fs-2 012 , short circuit hrc fuses 63 amps, part no. fs- 2 014e , auxilary contactor 2 no 2 nc 110v 415v 500v, part no. fs- 2 020 , pilot relay 12v dc, part no. fs- 2 026 , s e l r with cbct and p. t. el setting 50ma to 750ma with time delay 0. 1 to 1 sec in step of 0. 1 sec with test and reset micro switch and conc wire, part no. fs- 2 037 , isolator 200 amps reversing, part no. fs- 3 002b , isolator 300 amps reversing, part no. fs- 3 002c , air break contactor 185amps, fs- 3 003h , air break contactor 300amps, fs- 3 003l , air break contactor 325 330amps, fs- 3 003m , dmc terminal for i c and t g 300 amps, fs- 3 008a , dmc terminal for i c and t g 400 amps, fs- 3 008b , dmc terminal for outgoing partition 300 amps, fs- 3 009b , dmc auxilary terminal, fs- 3 010 , 3 pole magnetic o l relay type ct operated, part fs- 3 011a , ct operated thermal overload relay 4. 5 to 7. 5a with mounting kit, fs-3 011c , ct for overload relay,fs- 3 012 , 65 72 sq mm ammeter ct operated,fs- 3 012b , 65 or 72 sq mm voltmeter 0-600v, fs- 3 012d , pilot relay 12v dc, part no. fs- 3 026 , s e l r with cbct and p. t. e l setting 50ma to 750ma with time delay 0. 1 to 1 sec in step of 0. 1 sec with test and reset micro switch and conc wire,part no. fs- 3 041 25 amps contactor with 110v coil, part no. dpf-1 002a, hrc fuse base with carrier, part no. dpf-1 004, hrc fuse link,10 amps, part no. dpf-1 004a, e l. trip indication lamp, part no. dpf-1 006a, glass fuse. 1 amp, part no. dpf-1 007a, glass fuse. 2 amps, part no. dpf-1 007b, on off toggle switch, part no. dpf-1 008, incoming throughgoing dmc,moulded terminal with brass stud, part no. dpf-1 013, interconnecting dmc, moulded terminal with brass, part no. dpf-1 013a, condensor,16v,220 mfd. , part no. dpf-1 019, m 8 //bid details2 / 59