Get complete information related to latest Lynx Conductor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lynx Conductor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lynx Conductor Tenders.
Tender For bid to ras supply of flexible copper trailing cables d d - item 10 , item 20 , item 30 , item 40 , item 50 , item 60 cable,trg,atc,3.3kv gr,3.5cx50mm2,is9968 size & tvpe 3.5cx50 sq. mm 3.3 kv grade flexible atc conductor of class-s, epr le-3, insulated &black hofr nbr pvc type se-4 sheathed flexible trailing cable suitable for reeling/un-reeling operation. cable type- flexible, standard: is 9968(part 2) 2002 d.c. resistance at 20deg. c (ohms/km) power core max- 0.393 earth core max - 0.795. annealing test in %- (before stranding) 13.5 %. per sulphate test in g/m2- max. 5.00. conductor screeninq power core only material approx thickness mm - extruded semiconducting compound/ extruded semi conducting tape- 0.80. conductor material: annealed tinned copper, 6.6 klv grade, cable type: flexible, standard: is 9968(part 2) 2002 tests on insulation thickness (nom) mm core ldentification - power core-2.20 colour rpct red, yellow & blue for power cores & green for earth core tensile strength before ageing n/mm2- min.4.20 % variation after ageing (air oven)- max. +-30% % variation after ageing in (air-bb)- max. +- 30%. elongation before ageing in % - min.200% % variation after ageing (air oven)- max. +- 30% % variation after ageing in (air-bb)- max. +- 30%. hot set test hot set elongation- 175% permanent set 15%. lnsulation resistance constant (min.) m ohm km. at 27deg.c- min. 3670 at 90 deg.c-min 3.67. thick of lnner sheath min 2.00 mm. rein forcement- open braid of textile material physical test on outer sheath thickness (nom) / min mm- 3.50/ 2.60 colour black, over all diameter of cable mm- 52.00+-3.00. tensile strength ) /bid number : gem/2025/b/6811700 * /dated: 24-10-2025 & & / bid document 1 / 22 before ageing n/mm2 - min. 11.0 at 2oo elongation 4n/ sq. mm. % variation after ageing in (air-bb)-max. +- 50% elongation before ageing in %- min.250% % variation after ageing in (air-bb)- max. + 50%. hot set test hot set elongation- max.175% permanent set- max 15. oil resistance test variation in % in tensile strength- max. +-40% variation in % in elongation-max. +-40%. tear resistance in n/mm - min.5.0. flammability test period of burning after removal of flame- max. 60 sec. min unaffected portion from the lower edge of the top clamp - min 50 mm. test high voltage at room temp- 10 kv ac for 4 hours. water absorption test increase in capacitance 1 to 14 days max- 6% 7 to 14 days max- 2.5%., control trailing cable 12 c x 2.5 3 p x 1.5 (pair screened) 2 voltage grade 1.1 kv 3 reference standard generally confirming to is: 9968 (part- 1)1998 4 conductor a. material to is:8130/84 annealed tinned copper b. nominal area of cross section(sq. mm) i)-unscreened core (sq. mm.) 2.5 ii) - screened pair (sq. mm.) 1.5 c. flexibility class as per is:8130/84 class-5 d. maximum dc resistance of conductor at 20 deg. c i)-unscreened core (ohms/km) 8.21 ii)- screened pair (ohms/km) 13.7 5 insulation i) material epr type ie-2 to is:6380/84 ii) nominal thickness (mm) 1.0 6 two cores of 1.5 sq. mm. size twisted together to form a pair yes. 7 individual pair screening each pair of 1.5 sq. mm. size taped with rpct, screened with 0.2 mm nom dia of annealed tinned copper wires braid, taped with melinex tape. yes. 8 no of cores / pair i)-unscreened cores 12 ii)-screened pairs 3 9 identification of power cores by number printing on cores. 10 laying up (i) three screened pairs laid up together, taped with rubber proofed cotton tape to form group as "a" (ii) 12 unscreened control cores laid up together around group as "a" of screened pairs and taped with rubber proofed cotton tape applied with open spiral. 11 inner sheath a) material to is: 6380/84 hd hofr csp type se-4 b) minimum thickness (mm) 1.6 12 an open braid of nylon cord reinforced in between inner and outer sheath. yes. 13 outer sheath a) material to is: 6380/84 hd hofr csp type se-4 b) nominal thickness (mm) 2.5 14 nom. overall diameter of cable (mm) 33.0 tolerance on nom. overall dia
Tender For corrigendum : supply of supplying of 1.5 tr nominal capacity invertor type metal body , installation, testing and commissioning of of 1.5 tr inverter type ductable air cooled split ac unit as per item no.1 above in equipment room , providing and fixing heavt duty powder coated m s stand of suitable size made out of suitable guage ms shee , supply and fixing of 3 core 2.5 sq mm control cum transmission wiring and ac power supply cable of shielded copper conductor for looping between indoor and outdoor , supply and fixing of 4 core 1.5 sq mm control cum transmission wiring and ac power supply cable of shielded copper conductor for looping between indoor and outdoor , supply installation testing and commissioning including vaccumiazation and nitrogen testing of , supply installation testing and commissioning including vaccumiazation and nitrogen , supplying and fixing of 25 mm sizes of rigid upvc piping from outlet socket of ac unit complete with elbow , supplying and fixing dp sheet steel enclosure on surface or recess along with 25 or 32 a 230 v c curve dp mcb , supplying and fixing 5 amps to 32 amps rating, 240 or 415 volts c curve miniature circuit breaker suitable for inductive load of single pole and neutral , providing and fixing supply air grills of powder coated aluminum construction having a free area of not less than 70 percent without volume control dampers , supplying and installing of 150 mm width 50 mm depth 1.6 mm thickness nominal size of perforated hot dipped galvanised iron cable tray
Tender For corrigendum : establishing 2x20 mva, 110/11kv sub-station at br gate (savanthanahalli) along with construction of 110kv lilo line using lynxconductor from existing 110kv banavara-javagal sc line to the proposed 110/11kv substation at kolagunda gate for a distance of 0.122kms in arasikere taluk, hassan district on partial turnkey basis
Tender For establishing 2x20mva, 110/11kv sub-station at bhalki north and construction of 110kv lilo line to proposed 110/11kv bhalki north sub-station using lynxconductor from existing 110kv halbarga-bhalki dc ine for a distance of about 1.701kms in bhalki taluk, bidar district on partial turnkey basis including supply of all matching materials/equipments (excluding supply 11kv switchgear) and erection (including dismantling and civil works) of all materials/ equipment, testing and commissioning.
Tender For 1establishing 2x100mva, 220/110kv and 1x10mva, 110/11kv sub-station at tekkalakote (konchigere) village in siruguppa taluk & ballari district, 2.construction of 2nos. of 220kv terminal bays at 220kv somasamudra sub-station for termination of 220kv tekkalakote dc line in ballari taluk & district,3.construction of 2nos. of 220kv terminal bays at 220kv sindhanur sub-station for termination of 220kv tekkalakote dc line in ballari taluk & district,4.construction of 220kv dc line with drake conductor from existing 220kv sindhanuru sub-station to the proposed 220/110/11kv sub-station for a distance of 39.853km at tekkalakote (konchigere) village in siruguppa taluk & ballari district,5.construction of 220kv dc line using drake conductor from existing 220kv somasamudra sub-station to the proposed 220/110/11kv sub-station for a distance of 20.034km at tekkalakote (konchigere) village in siruguppa taluk & ballari district,6.stringing of second circuit with lynxconductor on existing dc towers of 110kv kurugodu-siruguppa sc line to the existing 110/33/11kv siruguppa sub-station for a distance of 47.318km in siruguppa taluk & ballari district, 7.construction of 110kv dc lilo line using lynxconductor from existing 110kv kurugodu-siruguppa line & 110kv sirigeri cross-tekkalakote line to the proposed 220/110/11kv sub-station at tekkalakote (konchigere) village for a distance of 3.531km in siruguppa taluk & ballari district, 8.construction of 110kv lilo line from second circuit of 110kv kurugodu-siruguppa line to the existing 110/11kv sirigeri cross sub-station for a distance of 4.309km in siruguppa taluk & ballari district, 9.construction of additional circuit from lilo point of 110kv allipura-somasamudra line to the existing 110kv tap line for a distance of 1.094km in siruguppa taluk & ballari district,10.construction of 1no. of 110kv terminal bay at existing 110/11kv siruguppa sub-station for termination of 110kv second circuit on existing dc towers of 110kv tekkalakote-siruguppa sc line to the proposed 220/110/11kv tekkalakote sub-station in siruguppa taluk & ballari district,11.construction of 1no. of 110kv terminal bay at existing 110kv kurugodu sub-station for termination of 110kv 2nd circuit on existing dc towers from 110/11kv siruguppa sub-station to 110/33/11kv kurugodu sub-station in kurugodu taluk, ballari district,12.construction of two additional line terminal bays at 110kv sirigeri cross sub-station for the work of construction of second 110kv lilo line to 110kv sirigeri cross sub-station using lynxconductor from proposed second circuit of 110kv kurugod - siruguppa line in siruguppa taluk, ballari district,13.decommissioning works at 220kv somasamudra and 220kv sindhanur sub-stations,14.decommissioning works in 220kv sindhanuru-tekkalakote line, 110kv kurugodu-siruguppa line, 110kv dc lilo line of 110kv kurugodu-tekkalakote line, 110kv sirigeri cross & 110kv allipura-somasamudra line,on partial turnkey basis, including supply of all materials/equipments (excluding supply of 1x10mva,110/11kv power transformer & 11kv switchgear), erection (including dismantling and civil works) of all materials/equipments, testing and commissioning.
Tender For supply of thin walled e-beam irradiated flexible cable with copper conductor, working voltage above 750 v & upto 1.8/3.0 kv grade, size: 95 sq mm as per rdso specn. no:elrs/spec/ elc/0019 (rev-4) of feb-2018 or latest in black colour. material must be procured from rdso approved sources only vide rdso item id:3100270. [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of service connector of 2.5 sq.mm cross section for connecting railway carriage fan and light fittings as per item no.wago make or equivalent as per the technical data: (1) type of wiring: side-entry wiring. (2) total number of connection points: 2. (3) total number of potentials: 1. (4) connection technology: cage clamp. (5) actuation type: push-in. (6) connectable conductor material: copper.(7) solid conductor: 0.5 - 2.5 mm 2/20 - 16awg. (8) fine stranded conductor: 0.5 - 2.5 mm 2/20 - 16awg. (9) strip length: 9 - 11mm/ 0.35 - 0.43 inch. (10) width: 8mm/ 0.315 inch. (11) height: 15.5mm/ 0.61 inch. (12) depth: 42 mm/ 1.654 inch. (13) colour: grey. (14) fire load (mj): 0.099 (mj). (15) weight(g): 5(g). this item has no approved sources in rdso/icf/rcf, hence to be procured from open market i.e. oem or its authorized dealers. [ warranty period: 30 months after the date of delivery ]
Tender For supply of tubular crimping socket for 150mmsq e beam cable conductor made of copper as per rcf spec no. edts200 rev 0 am-2 corr 3 item 1 suitable for lhb ac coaches. [ warranty period: 30 months after the date of delivery ]
Tender For supply of electrical item c c - flexible copper conductor , xlpe aluminium armoured power cabl , changeover switch 100 amp , axial panel cooling fan , 25 amp industrial plug and socket single phase , 100w led flood light , switch is 3854 and 16 amp socket outlet , screw driver tools kit se
Tender For supply of tubular crimping socket for 150mmsq e beam cable conductor made of copper as per rcf spec no. edts200 rev 0 am-2 corr 3 item 1 suitable for lhb ac coaches. [ warranty period: 30 months after the date of delivery ]