Get complete information related to latest Magnesium Chloride Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Magnesium Chloride Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Magnesium Chloride Tenders.
Tender For supply of procurement of common salt and chemicals potash grade for potash drilling : : - common salt , potassium chloride , xanthan gum , cmcpowder , magnesium oxide , magnesiumchloride , starch , soda ash , hydrophilic polymer aus plug
Tender For supply of chemicals and glassware for rdwsd dist. and sub-division water testing laboratory. - copper (ii) sulphate powder, crm (99.90%) 80gm, conductivity standard 1413, bnd (nist), iron standard solution 1000mg/l, bnd (nist, accordance with iso 17034), turbidity 4000 ntu calibration standard (accordance with iso 17034) 500ml, ph buffer 9.20, (nist, iso 17034) bnd 500ml, ph buffer 7.0, (nist, iso 17034) bnd 500ml, ph buffer 4.0, (nist, iso 17034) bnd 500ml, zirconium oxychloride octahydrate ar 100gm, glass- droppers, phenanthroline monohydrate 1, 10 5gm, with nabl certificatevolumetric pipette 10ml a class , micropipette micropipette(1-5ml), a class measuring cylinder 5ml, glassware cleaner 1ltr, for turbidity meter - cuvette , cuvette for uv quartz 1 pair, ar sodium thisulphate 500gm, barium chloried ar 500gm, permanganate potassium 500gm, phenolphthalein indicator 100gm, ferrous ammonium sulphate ar 500gm, potassium nitrate ar 500gm, iso-propyl alcohol ar 500ml, magnesiumchloride ar 500gm, glacial acetic acid ar 500ml, eriochrome black t ar 25gm, ammonium acetate ar 500gm, silver nitrate ar 25gm, calconcarboxylic acid ar (pr indicator) 25gm, ammonium chloride ar 500gm, ammonia solution ar 500ml, edta ar 500gm, conc. hydrochloric acid ar 500ml, ar hydroxylamine hydrochloride 500gm, potassium ar chromate 500gm, spadns ar reagent 25gm
Tender For tender for supply of supply and installation commissiong d d -supply installation testing and commissioning of 2tr 24000 btu per hour minimum bee 3 star rated confirming to is 1392 part 2 2018 inverter type cassette split ceiling mount air conditioner having wireless remote controller led display for indoor unit motorized vertical horizontal swing controls air filters uto restart with memory features inbuilt drain pump rotary scroll hermetically sealed compressor and initial charge of eco friendly refrigerant condensor and evaporator coils of copper material suitable for operation on 230v 10 single phase 50hz ac power supply the indoor unit shall be suspended from the ceiling using threaded rods including clamps bolts nuts etc and the outdoor unit shall be mounted on floor complete as required , supply and laying of soft drawn copper refrigerant pipe of suitable size for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation including necessary brazing jointing etc as required for cassette split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 25 mm dia minimum thickness of 1 2mm pvc drain pipe along with accessories and necessary clamps with an u trap at the end as required , supply and fixing of 75mm dia minimum 18mm thickness pvc covering pipe using necessary bend colloc clamps threded rod supports accessories etc for laying copper refrigernt line electrical cable and drain line as required. , supply and installation of floor mounted powder coated ms 25 x 25x5mm l angle frame including clamps bolts nuts vibrating dampers as required , drilling of hole using core cutting machine of size up to 100 mm dia in concrete stone wall ceiling for laying refrigerant lines etc and finishing the same with cement mortar after laying , dismantling shifting of old 2tr cassette split air conditioner having indoor and outdoor units associated refrigerant pipes electrical wires and drain pipes including pump down of refrigerant. , making of necessary alteration of existing gypsum false ceiling for installation of cassette air conditioner indoor units including necessary aluminium channel support gypsum board necessary accessories including painting to match for the existing false ceiling , supply installation testing and commissioning of 2tr 24000 btu per hour and iseer value five star rated and compliance with is 1391 part 2 2018 wall mounted inverter type hi wall split cooling inverter air conditioner having wireless remote controller with led display hermetically sealed scroll rotary compressor and eco friendly refrigerant initial charge of refrigerant condensor and evaporator coils of copper material air filter with auto swing auto restart features suitable for operation on 230v single phase 50hz ac power supply the indoor unit shall be fixed rigidly on wall using necessary frame the outdoor unit shall be mounted on floor laying and interconnection of standard length copper refrigerant piping as supplied by the oem between indoor and outdoor units complete in all respects as required necessary drilling of hole and finishing the same to match for the surrounding as required. , supply and laying of beyond the standard length supplied by the oem copper refrigerant pipe of size suitable for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation for hi wall split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 75mm dia minim