Tender For supply of operation of 4 x 300 tr hvac plant , cmc of 4 x 300 tr hvac plant , amc of water treatment plant , chemical cleaning of existing resin in the softener plants including removing of existing resin, identification of worn out resins, cleaning and revamping, operating the softener plant , replacing the existing resin make thermax model tulsion t42na and refilling the softener plant note the resin should be supplied before ist quarter of the contract and 4th rar bill will be released , replacing the existing compressor lubricant oil ici rl 68 filter drier core, filter mcquay, wuhan, china part no 735030528 removing the existing oil and submission of oil test reports , top up of r 134 a refrigerant gas as and when required to achieve optimum level of refrigerent in chiller make mcquay pfs 330.3 as per the approval of eic. , 50mm frp coating for existing cooling tower chilled water lines , providing chemical dosing for 4x300tr cooling tower to keep water quality with in permissible limit, including submission of water test reports
Tender For supply of tophat ceramic ehd 110 balzer's , beam balzer's part no. bk202697 suitable for barzers vacuum coating plant model no. bak 600/bak 640 or , spacer (sleev) stainless balzer's part no. bk 202735 suitable for barzers vacuum coating plant model , single pocket crucible balzer's , crucible drive motor balzer's
Tender For corrigendum : empanelment of agencies for supply of laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoridemeter: ph/ise benchtop meter with electrode stable, universal power adapter, literature, pc cable, meter test certificate electrode: ionplus fluoride and nitrate combination ion selective electrode, 1m cable, waterproof bnc benchtop ion meter (ise) along with fluoride, nitrate #electrode range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 relative accuracy 0.002 calibration points up to 5 calibration editing yes #mv/ rmv orp range 2500.0 mv resolution 0.1 relative accuracy 0.2 mv or 0.05 % of reading whichever is greater eh orp mode yes ise range 0 to 19999 resolution up to 3 significant digits relative accuracy 0.2 mv or 0.05 % of reading whichever is greater units ppm, m, mg/l, %, ppb, none calibration points up to 5 calibration editing yes calibration features timed end point, linear point to point, non-linear selectable auto-blank, low concentration range stability #temperature range -5 to 105 c, 23 to 221 f resolution 0.1 relative accuracy 0.1 offset calibration 1-point datalogging memory 2000 with time and date stamp log function manual, ready (include auto-read ), timed log edit delete individual points, group of points or all inputs ph electrode bnc, reference pin atc probe 8-pin mini-din #output rs232, usb power ac adapter included universal, 100-240 vac battery power optional 4 aas battery life 800 hrs, fluoride electrode of ion metersame make that of the ion meter, manifold filtration assembly* wide range of pumps and filtration flasks * high quality components * easily exchangeable elements *maintenance-free * low noise * added filters for enhanced pump longevity * filtration base with silicon stopper, cap & aluminium clamp connecting silicon tube technical specification for filtration flask set # high-pressure resistant tube # fiberglass filter membranes (47mm / 0.1 m) # ptfe disc filter #normal liquid filtration * specification for filtration glass set #suction bottle capacity(ml) 1000 ml # filter diameter(mm) 47/50 mm # * specification for filter flask * material: statinless steel 304, capacity: 300 ml (100 ml each) [ unit should consist of 3 flask so that 3 sample can be filtered simultanelously without any issue] # effective filtration area(cm2) = 9.6 cm2, outlet connector(mm) = 8 mm * specification for vaccum flask: #flow rate of the pump(l/min) = 17 l/minultimate vacuum(mbar) = 150 mbar # oil free, maintainance free, built in thermal protection to shut off when over heated., auto cut heater for distill water plant so that when water level decreases the heater is switch off automatically, voltage stabilizer capacity- 3 kva servo stabilizer 5 star rating, heating mantle (single station) should have digital energy regulator with multiple step power regulation automatic spill detection and saftey shutdown in built precision temperature control technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 420 degree celcius. accuracy: plus minus 1.0 degree celcius, power consumption : 150 w, heating mantle (combined unit) material of construction heating block: made with grade epoxy painted chemical resistant coating, aluminum block with 6 thermo wells for processing 6 different samples at a time. #racks: ss 316 # glassware: teflon coated # temperature range ambient + 10 deg c to 450 deg c # stability of temperature better than 0.5 deg c # controller consist of digital read out of temperature and time with 4 programmable ramps for each method. # number of programmable methods 20 numbers. # heating powers 1000w # heating position minimum 6 position # digestion time range -1 to 999 minutes # the system should have facility of acoustic signal at the end of completion of cycle to notify the operator. # the thermal digestion unit should have high thermal homogeneity # the setup should have small f
Tender For dismantling and erection of 1600 nb cw pumps discharge pipe lines of unit ii near chlorination plant of stage ii area and also providing of protective and anticorrosive membrane pipe coating treatment for above erected pipe line.
Tender For supply of redeployment of hpac package units and associated works at tax building mi road jaipur - gss sheet metal ducting , double layer canvas connection , supply air grills with aluminium volume control damper , aluminum conductor armoured cable , copper conductor armoured cable , plumbing work for drainage requirement , powder coating m.s. cable trays , wall opening , dismantling and removing the existing laid old power or control cables , dismantling or removing the existing fitted old package a.c. units , recovering the existing laid refrigerant piping of old hot gas and cold gas , dismantling the existing fitted old ms racks , dismantling or removing the old condensate drain piping , dismantling the existing old ducts of package units , dismentalling of lt panel from ac plant room , transportation of the existing fitted old dissmantled package a.c. units , itc of 7tr hpac package , supplying and charging of the refrigerant gas , copper referigerant piping , laying of recovered copper referigerant piping , providing ms structure , itc of following old recovered items , providing and fixing 25 mm x 5 mm g.i. strip , 06 mm thick rubber matting , liquid line filter drier , installation testing commissioning of existing electrical lt panel , end termination with brass compression gland and aluminium lugs , aluminium conductor power cable of 1.1 kv grade