Get complete information related to latest Magnetron Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Magnetron Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Magnetron Tenders.
Tender For repair replacement of internal wiring incl sub main wiring, mcb dbs, bldgs security lights and connected items in pocket 1 to 8 under ge roorkee - taking down old unserviceable point wiring of any description including all fittings and fixtures like switches, sockets, ceiling rose, fan regulator, tubelight,, mirror light,, ceiling light etc complete all as specified and directed., m&l for point wiring with 1.5 sqmm frls-h insulated, unsheathed, multistranded, 1100 volts grade copper conductor cable single core conforming to is:694 along with one run of 1.5 sqmm frls-h insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories / junction boxes / inspection covers etc of suitable size but not less than 20mm(od), concealed in wall/ floor etc including provision of earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass gi screws/ modular cover plate as required for mounting switches, sockets, fan regulator, etc. / modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator etc complete all as specified and directed for one light / ceiling fan / exhaust fan / call bell point controlled by one switch, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., all as per item no 2 here-in-before but one wiring in existing conduit for one light / ceiling fan / exhaust fan / call bell point controlled by one switch., all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one one light point controlled by two no. two way switch complete all as specified and directed, all as per item no. 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., m&l for sub main wiring along with earth wire with frls-h insulated copper conductor, single core cable drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for 2runs x 4 sqmm(ph & n) + 1run x 4 sqmm(earth wire):- (note: three runs of copper cable and one run of pvc conduit shall be measured as one unit length), all as per item no 11 here-in-before but 2runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), all as per item no 11 here-in-before but 2runs x 10 sqmm(ph & n) + 1run x 10 sqmm(earth wire), all as per item no 11 here-in-before but 4runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), notes for item no. 2.00 to 14.00(i) quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.(ii) if any beam / column / rock wall is encountered while cutting chases, that particular portion may be provided with pvc casing & capping or surface conduit for drawing cables and surface pvc gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) no cutting shall be done on ceiling for laying pvc conduit for ceiling fan point wiring. surface conduit or pvc casing capping may be
Tender For annual repair and maintenance of iei and eei to g.b. pant hospital at atlanta point wsd, apwd in svp. sw supply of labour and electrical items for iei and eei maintenance in g.b. pant hospital, svp - supply of following category labour to asssit wireman/assistant wireman in iei and eei maintenanceun-skilled, supply of following electrical for iei & eei maintenance work.1.5 sq. mm isi marked, frls pvc insulated, single core copper conductor cable, 4.0 sq. mm isi marked, frls pvc insulated, single core copper conductor cable, 6.0 sq. mm isi marked, frls pvc insulated, single core copper conductor cable, 10.0 sq. mm isi marked, frls pvc insulated, single core copper conductor cable, 16 sq. mm isi marked, frls pvc insulated, single core copper conductor cable, modular one way switch 5/6 a , similar to indoasian /roma/ziva, modular one way switch 15/16 a , similar to indoasian /roma/ziva, modular socket 5/6 a ,3 pin ,similar to indoasian /roma/ziva, modular socket 6/16 a ,3 pin ,similar to indoasian /roma/ziva, modular fan regulator 2 module ,similar to indoasian /roma/ziva, pvc batten holder, call bell/ buzzer, single phase, modular surface box 3-way with cover plate and frame similar to indoasian /roma/ziva, modular surface box 6-way with cover plate and frame similar to indoasian /roma/ziva, modular surface box 8-way with cover plate and frame similar to indoasian /roma/ziva, modular surface box 12-way with cover plate and frame similar toindoasian /roma/ziva, pvc frls conduit pipe 20 mm, pvc frls conduit pipe 25 mm, pvc frls channel 32mm, pvc junction box 20mm 1-way, pvc junction box 20mm 2-way, pvc junction box 20mm 3-way, pvc junction box 20mm 4-way, pvc junction box 25mm 1-way, pvc junction box 25mm 2-way, pvc junction box 25mm 3-way, pvc junction box 25mm 4-way, pvc elbow 20 mm, pvc elbow 25 mm, pvc bend 20 mm, pvc bend 25 mm, pvc nail clamp 20 mm, pvc nail clamp 25 mm, pvc ceiling rose, 3 pin, 6 amps. to 32 amps. ratings , sp mcb, "c" curve, 10 ka breaking capacity, tp c-type mcb 32 amps., tpn c-type mcb 32 amps., tpn isolator 40 amps., tpn isolator 63 amps., tpn isolator 100 amps., tp mccb 16ka 100 amps., tp mccb 25ka 200 amps., tp mccb 50ka 400 amps., modular ac distribution box 20amps with plug top, mini modular sp mcb 20amps., 5 amps 3-pin plug top, 16amps 3-pin plug top, pvc insulated aluminium service wire twin core 6.0 sqmm, capacitor 2.5 mfd, procelain 500 a kit kat fuse unit open type, fuse wire 300amps, aluminum lugs 35 sqmm, aluminum lugs 50 sqmm, aluminum lugs 90 sqmm, aluminum lugs 120 sqmm, aluminum lugs 150 sqmm, aluminum lugs 185 sqmm, aluminum lugs 240 sqmm, aluminum lugs 300 sqmm, aluminum lugs 400 sqmm, 1-star ceiling fan of sizes 1200 sweep white in colour, exhaust fan 300 mm sweep metal body heavy duty, led street light fittings 50 w, led batten type tube light 20w, led retrofit tube light frame,20w, led tube lamp,20w, led bulb 9w, b22 3-star, led bulb 0.5 w, b22 (red and green), fr - electrical insulation tape, al. alloy/ cadmium plated iron screws, 35 mm, iron screws, 25 mm x 7 mm, iron screws, 35 mm x 7 mm, iron screws, 52 mm x 6 mm, nylon cable tie 300mm, ball bearing 6201, ball bearing 6202, wall grip, hylem sheet full 8x4 feet, wall fan 450 mm (metal body), wall fan 600 mm heavy duty (metal body)
Tender For annual repair and maintenance of iei to dhs office, cmo store, anm hostel and other annex buildings of dhs at atlanta point ,wsd apwd at svp. sw supply of electrical items for iei and eei maintenance - supply of following electrical items.1.5 sqmm isi marked, frls pvc insulated single core copper conductor cable, 4.0 sqmm isi marked, frls pvc insulated, single core copper conductor cable, sp 5/6 amps one way switch piano type isi marked, sp 15/16 amps one way switch piano type isi marked, 3 pin 5/6 amps socket outlet piano type isi marked, 6 pin 15/16 & 5/6 amps socket outlet piano type isi marked, bell push piano type, pvc batten holder, call bell/ buzzer, stepped type pt fan regulator socket type, pvc surface box with cover plate 1 way, pvc surface box with cover plate 2 way, pvc surface box with cover plate 2 way (power plug), pvc surface box with cover plate 3 way, pvc surface box with cover plate 4 way, pvc surface box with cover plate 5 way, pvc surface box with cover plate 6 way, pvc surface box with cover plate 8 way, pvc conduit pipe 20 mm, pvc conduit pipe 25 mm, pvc channel 32mm, pvc junction box 1 way 25mm, pvc junction box 2 way 25mm, pvc junction box 3 way 25mm, pvc junction box 4 way 25mm, pvc elbow 20 mm, pvc elbow 25 mm, pvc nail clamp 20 mm, pvc nail clamp 25 mm, nylon cable tie 250mm, pvc ceiling rose 3 pin, 6 amps to 32 amps ratings sp mcb c curve 10 ka breaking capacity, isolatore 4 pole 63 amps, isolatore 4 pole 100 amps, led tube light batten 20w, led tube lamp 20 w, energy saving 1 star ceiling fan of sizes 1200 sweep white in colour, exhaust fan 300 mm sweep metal body, capacitor 2.5 mfd, ball bearing 6201, ball bearing 6202, fr electrical insulation tape, al. alloy or cadmium plated black iron screws, 20 mm, iron screws, 25 mm x 7 mm, iron screws, 35 mm x 7 mm, wall grip, wall fan 450mm (metal body), 16amps 3-pin plug top, mini modular sp mcb 20amps., tp mcb 32 amps, c-type, led street light 50w
Tender For repair / replacement of internal unserviceable point wiring / fitting / fixture and connected accessories work in karam singh enclave and bana singh enclave under age e&m-iv of ge (south) bathinda at bathinda mil stn - taking down carefully existing copper/aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, bell pushes, ceiling roses, pendants, regulators, sockets, light fitting, call bells etc. removing materials to store for keeping in safe custody or for taking credit(credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc. to match existing colour complete all as specified and directed., material and labour for concealed one light / fan point controlled by one, one way modular switch 06 amp wiring with 1.5 sq mm nominal cross sectional area, single core, 1100 volt grade, multi-stranded, pvc insulated, unsheathed frls copper conductor cable with and including continuous earth wire of size 1.5 sq mm nominal cross sectional area, single core, 1100 volts grade, multi-stranded, pvc insulated, unsheathed, frlsh copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic pvc conduit of 20 mm dia in medium grade complete with and including all pvc conduit accessories concealed into wall by cutting of chases in wall complete and including modular metal flush boxes not less than 1.6mm thick alongwith modular cover plate with frame of any size for mounting of any type modular switches/sockets/bell switch /fan regulator and brass screws, cup washers etc complete, making good the distributed surfaces completely matched and finished with existing surface including painting of walls etc complete all as specified and directed. , all as per srl item no. 2.00 (here-in-before) but one 3 pin socket outlet 6 amp on same board point, complete all as specified and directed, all as per srl item no. 2.00 (here-in-before) but one 3 pin socket outlet 6 amp on the independent board point with pvc fr-lsh cable size 2.5 sqmm complete all as specified and directed., all as per srl item no. 2.00 (here-in-before) but one bell point controlled by one bell push on independent board complete all as specified and directed., all as per srl item no. 2.00 (here-in-before) but one light point controlled by two way switch complete all as specified and directed., all as per srl item no. 2.00 (here-in-before) but for 15/16 amp socket out let/power point by using 2.5 sqmm pvc insulated unsheathed copper conductor cable fr-lsh multi strand on independent board including provn of 2.5 sqmm unsheathed, multi stranded copper conductor cable fr-lsh continues as earth wire connected to earth dolly etc complete all as specified and directed, all as per srl item no. 2.00 (here-in-before) but for 15/16 power point (ac & geysers) by using 4.0 sqmm pvc insulated unsheathed copper conductor cable fr-lsh multi strand on independent board including provn of 4.0 sqmm unsheathed, multi stranded copper conductor cable fr-lsh continues as earth wire connected to earth dolly etc complete all as specified and directed, material and labour for one light / fan point controlled by one, one way modular switch 06 amp wiring with 1.5 sq mm nominal cross sectional area, single core, 1100 volt grade, multi-stranded, pvc insulated, unsheathed frls copper conductor cable with and including continuous earth wire of size 1.5 sq mm nominal cross sectional area, single core, 1100 volts grade, multi-stranded, pvc insulated, unsheathed, frlsh copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and in existing rigid non-metallic pvc conduit including modular metal flush boxes not less than 1.6mm thick alongwith modular cover plate with frame of any size for mounting of any type modular switches/sockets/bell switch /fan regulator
Tender For repair replacement of internal unserviceable point wiring fitting fixture and connected accessories work in tarapore enclave, khetrapal enclave and abdul hamid under age em iv of ge(s) bathinda at bathinda mil stn - taking down carefully existing copper/aluminum point wiring (light,fan, socket or power) complete including fixture and fittings such as switches, bellpushes, ceiling roses, pendents, regulators, sockets, light fitting, call bells etc removing materials to store for keeping in safe custody or for taking credit(credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc. to match existing complete all as specified and directed., m & l for point wiring with multi-stranded copper conductor, single core, pvc insulated and unsheathed cable, including pvc insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, gi terminal boxes, modular frame & cover plate (suitable for modular switch/sockets) comprising the following: -, one light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. with 1.5 sq. mm (nominal area) cable & 1.5 sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit all as specified., one socket outlet three pin, 6 amp, on the same board, with 1.5 sq. mm (nominal area) cable & 1.5 sq. mm (nominal area) cable as earth continuity conductor, all as specified, one socket outlet three pin, 6 amp, independent, with 1.5 sq. mm (nominal area) cable & 1.5 sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit all as specified., one bell/buzzer point controlled by one push button with 1.5 sq. mm (nominal area) cable & 1.5 sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit all as specified, one light point controlled by two way switch. with 1.5 sq. mm (nominal area) cable & 1.5 sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit all as specified., one socket outlet three pin, 5/15 amp, independent, with 2.5 sq. mm (nominal area) cable & 2.5 sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit all as specified., one light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. with 1.5 sq. mm (nominal area) cable & 1.5 sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic pvc medium duty concealed conduit all as specified., one socket outlet three pin, 6 amp, on the same board, with 1.5 sq. mm (nominal area) cable & 1.5 sq. mm (nominal area) cable as earth continuity conductor, all as specified., one socket outlet three pin, 6 amp, independent, with 1.5 sq. mm (nominal area) cable & 1.5 sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic pvc medium duty concealed conduit all as specified., one socket outlet three pin, 5/15 amp, independent, with 1.5 sq. mm (nominal area) cable & 1.5 sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic pvc medium duty concealed conduit all as specified., one bell/buzzer point controlled by one push button with 1.5 sq. mm (nominal area) cable & 1.5 sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic pvc heavy duty concealed conduit all as specified., m & l for inverter wiring with multi-stranded copper conductor, single core, pvc insulated and unsheathed cable,one light point /one 5 amp socket point only.including drawn though pvc conduct all as specified and as directed., s&f switch modular type single pole, one way, 6 amp, one module, complete all as specified., s&f switch modular type single pole one way, 16 amp, one module, complete all as spe