Web Analytics Made Easy - StatCounter

Main Fuse Tenders

Get complete information related to latest Main Fuse Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Main Fuse Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Main Fuse Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45048307 Due date: 31 Jul, 202631 Jul, 2026 NA
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp

Central Government/Public Sector

CTN :45619937 Due date: 10 Jul, 202610 Jul, 2026 NA
Tender For tender for supply of head light assy , indicator assy , tail light assy , fog lamp assy , main fuse box , horn set low and high , flasher unit , wiper unit control , oil sending unit , wiper motor , l t wire 4mm , fan big size , fuse 60 amp , insulation tape roll , plastic tape , temperature unit , fuse 10 , 15 , 20 amp , wiper blade , rust cleaner big size , pull and push switch , round clip 08 no and 10 no , head light bulb 100 90w 12 volt , bulb 67 no12 volt , bulb 53 no 12 volt , brake switch , reverse switch , alternator assy , fan belt tata cummins , ac belt , accelerator cable with end , air filter primary and secondary , fuel filter primary and secondary , baby filter , engine oil filter , tappet cover gasket , gear selector top cover , selector rod end , bolt 10mm 12mm , gear lever bush round type , annabond tube big size , hinge , nut with bolt 12mm , 13mm , with washer , power steering filter , power steering pipe , clutch cylinder assy upper , sleeve cylinder assy lower

CTN :45419880 Due date: 13 Jun, 202613 Jun, 2026 NA
Tender For supply of hero hf deluxe motorcycle into hybrid lectric stelth mobility vehicle d d - hub motor kit , lithium ion battery , motor controller , charger unit , dc-dc converter , battery box fabrication , heavy wiring kit and connectors , main fuse mcb , ignition switch , rear disk brake calipers , digital meter , tyre with nozzle fitment , bike wrapping vinyl

Central Government/Public Sector

CTN :45086045 Due date: 26 May, 202626 May, 2026 NA
Tender For supply of ht switchboard panel (nflp) / vcb panel, 6 panel, 6.6kv, 630a , ht switchboard panel (nflp) / vcb panel, 5 panel, 6.6kv, 630a , ht switchboard panel (nflp) / vcb panel, 14 panel, 3.3kv, 1250a , ht switchboard panel (nflp) / vcb panel, 14 panel, 3.3kv, 630a , ht switchboard panel (nflp) / vcb panel, 13 panel, 3.3kv, 1250a , ht switchboard panel (nflp) / vcb panel, 13 panel, 3.3kv, 630a , ht switchboard panel (nflp) / vcb panel, 10 panel, 3.3kv, 800a , ht switchboard panel (nflp) / vcb panel, 9 panel, 3.3kv, 1250a , ht switchboard panel (nflp) / vcb panel, 8 panel, 3.3kv, 630a , ht switchboard panel (nflp) / vcb panel, 7 panel, 3.3kv, 630a , ht switchboard panel (nflp) / vcb panel, 6 panel, 3.3kv, 1250a , ht switchboard panel (nflp) / vcb panel, 5 panel, 3.3kv, 630a , ht switchboard panel/ vcb panel comprising of single vcb (single vcb in nflp enclosure) , 3.3kv, 630a , ht switchboard panel/ vcb panel comprising of single vcb (single vcb in nflp enclosure) , 3.3kv, 400a

CTN :44991397 Due date: 15 May, 202615 May, 2026 NA
Tender For supply of fuse holder 3p 22x58mm ch223du eaton , fuse 125a 400v c22m125 eaton , main fuse 170m6466 kone idlz108 , fuse 80a 80et bussmann

State Government

CTN :43634844 Due date: 16 Apr, 202616 Apr, 2026 3.43 Crore
Tender For corrigendum : supply, installation and commissioning of 11 kv vcb switchboard of specified ratings at the power house of rammam hydel project stage-ii, wbsedcl including dismantling of existing siemens 8bk20 panel and shifting of the same to store - supply, installation and commissioning of 11 kv vcb switchboard of rating and other details specified within the tender document at the power house of rammam hydel project stage-ii, wbsedcl including dismantling of existing siemens 8bk20 panel and shifting of the same to store

Central Government / Public Sector

CTN :44588001 Due date: 14 Apr, 202614 Apr, 2026 NA
Tender For portable inverter type single phase welding machine as per the following specification :-(1)type of welding machine : portable inverter type single phase welding machine (2) input voltage frequency: 50hz (3)output current range: 20-220 amp. (4) type of cooling : air cooled (5) provision of main fuse protection: yes (6) length of earth cable: 10 metres (7) length of welding holder cable: 10 metres (8) input power capacity: 6-8 kva (9) efficiency in percentage: 80-95 (10) power factor: 0.91-1 (11)primary power supply: 220-240v ac , 50hz. (12) primary continuous current in amp.: 10 amp-20 amp (13) driver adjustment range: 0-65

Central Government/Public Sector

CTN :44514282 Due date: 07 Apr, 202607 Apr, 2026 NA
Tender For tender for supply of spares for general maintenance -fuses hrc-l and t-hf-10a , fuse hn63a sf94940size000 , fuse hn100a sf94941size000 , fuselink hrc-l and t-hn-63a , fuselink hrc-l and t-hn-100a , fuse hn125a sf94946 size000 , fuselink , hrc-l and t- hn-160 a-size 00 , fuselink hrc-l and t-hn-160a , fuselink hrc-land t-hn-250a , fuselink hrc-l and t-hn-250a , fuselink , hrc-l and t- hn-400 a-size ii , fuselink hrc-l and t-hn-400a , fuses hrc-siemens-3na7-10a , fuses hrc-siemens-3na7-16a , fuses hrc-siemens-3na7-25a , fuses hrc-siemens-3na7 32a , fuses hrc-siemens-3na7-80a

Central Government / Public Sector

CTN :44536439 Due date: 08 Apr, 202608 Apr, 2026 NA
Tender For corrigendum : portable inverter type single phase welding machine as per the following specification :-(1) type of welding machine : portable inverter type single phase welding machine (2) input voltage frequency: 50hz (3) output current range: 20-220 amp. (4) type of cooling : air cooled (5) provision of main fuse protection: yes (6) length of earth cable: 10 metres (7) length of welding holder cable: 10 metres (8) input power capacity: 6-8 kva (9) efficiency in percentage: 80-95 (10) power factor: 0.91-1 (11)primary power supply: 220-240v ac , 50hz. (12) primary continuous current in amp.: 10 amp-20 amp (13) driver adjustment range: 0-65.
 Loading, Please wait...

Connect us via What's Up