Get complete information related to latest Manometer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Manometer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Manometer Tenders.
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - hurl barauni township; design and supply of water pre-treatment plant of 30 cubic meter per hour capacity (2 nos) at hurl barauni township; as per scope of work
Tender For corrigendum : supply of repair and preventive maintenance of dg set ranchi oa - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva //bid details 2 / 35
Tender For corrigendum : providing of repair maintenance of dg set hazaribag - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva
Tender For corrigendum : providing of repair and maintenance of dg set under daltonganj - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva
Tender For corrigendum : rate contract for 02 years( extendable) for purchase of various types of consumables for department of aneaesthesiology, pgims, rohtak- heat & moisture exchange filters (hmef): hepa bacterial and viral fi with hme properties offering optimum hydrophobic filtration performance. gas sampl port, for end tidal co2 monitoring. recommended tidal volume range 150-1200ml.ev pleated filter medium to allow maximum filtration efficiency with minimal resistance flow. low dead space, not more than 45-55 ml. single use, sterile ece/usfda/iso/ , heat&moisture exchangers (hme) filter for pediatric us , recommended tidal volume <600ml.low weight. low dead space. suitable for b ventilated and spontaneously breathing patients. low resistance to flow. corrugated pa medium with high efficiency to recover about 75% of the energy and moisture. single sterile. ece/usfda/iso , heat & moisture exchangers (hme) for spontaneous breathing in tracheostomized patients. suction port to allows access to suct , catheter. clear housing to allow visualization of contamination. integrated oxygen port allow delivery of supplemental oxygen. recommended tidal volume range from 1000ml.compact and lightweight. corrugated paper medium device can be used fo maximum period of 24 hours. single use sterile. minimum resistance anti occlus mechanism. ece/usfda/iso , epidural set. a set containing tuohy's epidural needle minimum length 80m 16g, 17g and 18g, and corresponding gauge epidural catheter with closed tip and th lateral eye, length 90-100 cm and flat filters 0.2 micrometer hydrophilic two way, fill area approx 4.91 cm², priming volume 0.75 ml all connections should be of luer lock ty lor(loss of resistance) syringe, presterilized. ece marked/usfda approved , combined spinal epidural set. containing 18 g touhy epidural needle minimum 80 mm length. pencil point, spinal needle with twist lock system, marking tuohy's needle hub and depth marking on tuohy's needle hub containing correspond clear catheter with connection, closed end and 3 lateral eye of approx. length 90-100 with epidural filter 0.2 micrometer hydrophilic two way, epidural sponge and lor (loss resistance) syringe. ece marked/usfda approved - , needle for spinal anaesthesia, quincke type, same colour coding the hub and stylet, presterilized. usfda and europen ce approved- , (a) 23 g, 90mm length od approx 0.64 mm, , (b) 24g,90mm length od approx 0.5mm with/without introducer , (c) 25g, 90 mm , (d) 26g, 90 mm , (e) 27g, 90mm , paed. spinal needle without introducer, colour coded length 50mm, g, od 0.5 mm, presterilized. usfda and europen ce approved , cuff manometer: allows controlled initial cuff inflation. intermittent press monitoring facility. instant visual confirmation of intra-cuff pressure. simple operation pressure adjustment without need for disconnection or introduction of syringe into syst solid green zone indicates usual cuff pressure range for tracheal & tracheosto tubes.connecting tube is supplied with the gauge for convenient positioning. portable ga and clips easily into pocket. , face mask- clear, reusable, pvc material, transparent for good visibil adjustable cushion for better comfort. , sizes:- , a) 0, , b) 1, , c) 2, , d) 3,0) 4,1) 5- , anatomical facemask made up of antistatic inflating pad, malleable, anatom. chaned to give precise seal and fit comfortably, sizes 1.2.3.4 , disposable lma with preformed curve 90 degree like ilma with airwa tube with standard connectors for anaesthesia circuit. us fda approved. sizes 1, 1.5,2, 2.5,3,4,5 , resuable pressure infusion bag for administration of fluid to patient unde pressure, compatible with 500 ml fluid bags, flexible, stury, pvc tubing and manometer stop cock and hand pump, latex free , clear pressure- monitoring lines, which can withstand pressure up to 500 psi with minimal damping, non kinkable, pre-sterilized, disposable, id/ed1/2 mm. length 100 cm, 150cm & 200 cm. low dead space but pe may be optional
Tender For corrigendum : procurement of medical consumables items for use by the cardiology department, goa medical college, bambolim - injectable cardiovascular ultrasound contrast agent comprised of lipid-coated echogenic microbubbles filled with octafluoropropane gas or equivalent approved agent (cost comparison will be based on per study cost); in remarks - please detail the dose required per study per the instructions for use, disposable electrodes designed specifically for patient monitoring, disposible electrodes designed specifically for stress testing - please quote only those that are specifically designed for stress testing, disposible electrodes designed specifically for holter monitoring - please quote only those that are specifically designed for holter monitoring, disposable defibrillator patches (anterior and posterior) for use with philips brand defibrillators, disposable radiolucent defibrillator patches (anterior and posterior) for use with philips defibrillators, printer paper roll for philips mrx defibrillator and for efficia defibrillators, thermal printing paper for sony thermal printer used with echocardiography machines (model up/d-897), ultrasound jelly for echocardiography 5 litre pack, ecg thermal printing paper for use with philips pagewriter tc20 ecg machine; philips make only, ecg thermal printing paper for use with ge mac 5500 hd ecg/stress testing machine; ge make only, ecg thermal printing paper for use with bpl cardiart 6208 view plus ecg machine; 80 mm width roll, filter for hamilton ventilator hma anti-bacterial filter, flow sensor for hamilton g5 ventilator, oxygen cell for hamilton g5 ventilators, oxygen sensor medtronic pb840 ventilators, oxygen sensor medtronic pb840 ventilators, oxygen sensor medtronic pb840 ventilators, abg machine sensor cassette for radiometer abl 9 machine - 200 tests with 60 days validity with ph, pco2, po2, hct, na, k, ca++, chloride, lactate, abg machine ssolution pack for radiometer abl 9 machine (sp9), ventilator circuits (two limb) for adult patients, non-invasive ventilator face mask, nasal prongs for pediatric patients, normal saline 1 l pouch pack suitable for use with pressure infusor bag, normal saline 0.5 l pouch pack suitable for use with pressure infusor bag, pressure bag with manometer for iv infusion/pressure infusor bag, silk suture sterilized and packed with cutting needle 1.0 silk nw 5062 or equivalent, silk suture sterilized and packed with round body needle 1.0 silk nw 5063 or equivalent, surgical skin stapler with stapler cartridge for pacemaker pocket closure, staple remover, surgical disposible scalpel blade only number 11, surgical disposible scalpel blade only number 15, iodine impregnated antimicrobial transparent incise drape 23 x 23 cm, film transparent dressing with non-adherent pad 3 1/2 inches x 6 inches (9 x 15 cm), packing material for cath lab use 5 cm width x 200 metres roll, packing material for cath lab use 7.5 cm width x 200 metres roll, packing material for cath lab use 10 cm width x 200 metres roll, packing material for cath lab use 15 cm width x 200 metres roll, packing material for cath lab use 20 cm width x 200 metres roll, packing material for cath lab use 25 cm width x 200 metres roll, packing material for cath lab use 30 cm width x 200 metres roll, ethylene oxide (eto) gas cartridge, labelling instrument for packed items for cath lab, printer ribbon for use in labelling instrument l-1 will be calculated for labelling instrument with label rolls (total quantities), label roll for use with instrument quoted for in labelling instrument with built in eto exposure indicator, label roll for use with instrument quoted for in labelling instrument with built in steam exposure indicator, biological indicator for use in eto sterilizer, biological indicator for use with autoclave sterilizer, incubator for use with biological indicators quoted above l-1 will be calculated for incubator with total quantities of biological indicators in above t