Get complete information related to latest Mask Aligner Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Mask Aligner Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Mask Aligner Tenders.
Tender For corrigendum : procurement of spares for balluff make pft for ntpc kahalgaon - pos f/b transmitter,balluff,24vdc, pos f/b transmitter,balluff, control arm,btl2-gs10-200-a,balluff, control arm,btl2-gs10-0750-a,balluff, connector,bks-s32m-05,balluff, position transmiter,btl5-f-2814-1s
Tender For supply of 80 watt single phase motor, 220/240 v ac, 50 hz motor along with the tension spring , conformal coated controller pcb along with transmitter card and receiver card for boom barrier , position sensor and photo cell safety sensor unit along with remote key for boom barrier model
Tender For bid to ras bid to ras supply of w90418113033 motorized temp control valve for cold gas , w90418113076 position transmitter for primary water temp control valve , w90418113068 position transmitter for cold gas temp control valve , w90418113025 actuator for cold gas temp control valve , w90415208017 actuator for primary water temp control valve , w90418113041 motorized temp control valve for primary water
Tender For corrigendum : annual maintenance contract for midas maskaligner - amc for midas maskaligner (mda-80fa), amc for midas maskaligner (mda-80fa) for 1 year as per scope of work attached as an annexure-i & acceptance criteria attached as an annexure-ii at the end of tender document.
Tender For corrigendum : supply of electrical actuator for dia 2500 bf valve with integral starter and lvdt type position transmitter , electrical actuator for dia 800 bf valve with integral starter and lvdt type position transmitter , electrical actuator for dia 600 bf valve with integral starter and lvdt type position transmitter , electrical actuator for dia 500 bf valve with integral starter and lvdt type position transmitter , sec. gear box for dia 800 bf valve as per enclosed spec. cde-18-3396 rev. 01 and annexure-b , sec. gear box for dia 600 bf valve as per enclosed spec. cde-18-3396 rev. 01 and annexure-b , sec. gear box with limit switch for dia 600 bf valve as per enclosed spec. cde-18-3396 rev. 01 and a , sec. gear box for dia 500 bf valve as per enclosed spec. cde-18-3396 rev. 01 and annexure-b , sec. gear box for dia 400 bf valve as per enclosed spec. cde-18-3396 rev. 01 and annexure-b. , electrical actuator for dia 1800 bf valve with integral starter and lvdt type position transmitter , limit switch (1 set) , o-ring (1set) , pw contac. (2set) pw mod(2set) ctrl module(2 set) tolr - (2 set)
Tender For supply, storage, installation, commissioning and trial run of electro-mechanical equipment at raw water and clear water pumping station under kanchrapara municipality. - for rwps, supply, delivery , storage, installation, testing & commissioning of vertical turbine type centrifugal pump with cashion pipe ,column assembly, discharge head, sole plate, motor stool and all other accessories all complete of 750m /hr discharge at a head of 29 mtr at duty point as per technical specification . maximum allowable speed of pump shall be 1000 rpm., supply, delivery , storage, installation, testing & commissioning of vertical, scim ,tfec, 110 kw (minimum), 415 v 10% , 50hz 05%, speed 1000 rpm (syn) , to vertical pump duty motor to match with pump at sl no- (1) complete with coupling hub and all other accessories as per specification., supply, delivery , storage and installation at site of ms pipes, specials, joints, flanges as per specification and technical offer. (for both individual pump delivery pipe and extended part of common manifold if required) ., supply, delivery and installation and commissioning of valves complete at site with fixture as per specification and technical offer & as follows :-, di butterfly valve for delivery side of pump fitted with electrical actuator suitable for local and control desk operation and display system for the individual pump delivery pipe line. (350 mm minimum))(pn 16 type), di non-return valve for individual pump delivery pipe line. (350 mm. minimum))(pn 16 type), supply, delivery at site and storage of m.s. dismantling joint assembly for the individual pump delivery pipe line as per specification (350 mm minimum)., supply, delivery ,storage and installation at site of pressure gauges complete with fittings and fixture as per specification, pressure gauge for delivery side (0 10 kg / cm2), supply, delivery ,storage and installation at site of pressure transmitter complete with fitting and fixture as per specification as follows:-, pressure transmitter for delivery side ( 0 10 kg / cm2 ), supply, delivery at site and installation of m.s. structural materials for cable tray / rack, panel installation supports, pipes & valves supports, fabricated stairs & all other fabrication work., lt panel, modification / retrofitting/expansion/addition of the existing pmcc with supply , delivery & installation of a new additional motor starter feeder at rwph in order to accomodate the extra pump-motor feeder of requisite rating not less than 110 kw .the modification/addition should match/synchonise the existing panel and should ensure smooth operation of the complete panel as a single entity and should be fit to install at the existing pump house., retrofitting of existing control desk at site with supply,wiring, installation of additional items like temparature scanner , multifunction meter , microprocessor based position indicator, digital pressure indicator,tnc switch, push button switch, indication lamps etc .as required to complete for the new pump motor set., supply ,delivery, laying, installation of power cable of adequate size from motor feeder to motor .(min. 2 run x 3core , 185 sq mm xlpe armoured al. for each feeder), supply ,delivery, laying, installation of power cable of adequate size and length from pmcc to motor space heater . (min. 3 core 2.5sq mm. armoured cu for each motor), supply ,delivery, laying, installation of power cable of adequate size and length from pmcc to valve actuator etc. elsewhere required. (min . 4 core 2.5 sq mm. armoured cu), making end termination of all the power cables as stated in sl no 11,12,13 with all necessary equipments like termination kits(dry type), lugs , glands etc , installed for the modification job., supply ,delivery, laying, installation of control cables of different size as required for the purpose and length for completing the different control connections between control desk, motor feeders , lpbs, pmcc etc.to the satisfaction o