Web Analytics Made Easy - StatCounter

Measurement Unit Tenders

Get complete information related to latest Measurement Unit Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Measurement Unit Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Measurement Unit Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :40032985 Due date: 06 May, 202506 May, 2025 NA
Tender For corrigendum : supply of inertial measurement unit 152.4x127x104mm

corporations/Associations/Others

CTN :40126145 Due date: 05 May, 202505 May, 2025 2.62 Lacs
Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s

corporations/Associations/Others

CTN :40126147 Due date: 05 May, 202505 May, 2025 2.62 Lacs
Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s

Central Government/Public Sector

CTN :40097466 Due date: 14 May, 202514 May, 2025 NA
Tender For supply of thermal conductivity measurement unit following transient planar source technique

Central Government And Public Sector

CTN :40065883 Due date: 08 May, 202508 May, 2025 1.80 Crore
Tender For supply of toy testing equipment for crcl - degree automatic flammability tester , horizontal and vertical flame , mouth-actuated catapult endurance tester for toys , push pull test stand , pen-cap air flow tester , noise testing stand , wide-mouth clamp , clamp for wheel tension , hook test fixture for cords and loops , toys chest lid tester , baby stroller testing machine rotating test , test finger probe and accessibility probe , baby trolley dynamic durability testing machine , baby trolley handle durability , toy kinetic energy tester , baby stroller handle dynamic durability tester , laboratory drying oven , glow wire test apparatus , impact test table , seam clamp for toys tension , mouth-actuated tester , toys flammability tester , sharp edge tester , sharp point tester , flammability testing nailed , dynamic strength tester and 2 , high chair comprehensive testing , toys scooter steering tubes strength tester , small part cylinder , high chair back and arm impact testing machine , ball impact tester , kinetic energy tester , colour fastness to dry cleaning , noise meter , surface flash tester , small torque fixture , rattle test template , middle torque fixture , flexure tester , long - mouth clamp , two pronged clamp , three pronged clamp , average speed tester , brake performance tester , motor brake performance testing ramp , small ball test template , large torque fixture , hand held metal detector , ring gauge , imada digital force gauge , flat clamp , tensile tester , compression test disc , bite tester , tension clamp , motor horizontal brake performance tester , en drop tester , gap test round , short mouth clamp , liquid leak test needle , hair clamp , bench vice , feeler gauge , static strength test , test platform block , dynamic strength test load , static strength test load , overload test loads for ride-on toys and seats , air compressor , loads for stability test , toy handlebar resistance to separation tester , electronic metronome , wheeled toys tumble test steps , plastic and film thickness gauge , toy tester jaw entrapment risk test fixtures , torque gauge gt-tohnichi , part 1 weight cantry crane , toy calibrated test weight , yo-yo balls measurement , breakaway feature separation , toy tester separation tester , part 1 self-retracting ropes tester , toy safety tester self-retracting ropes tester , part 1 length of ropes and chains tester , test instruments length of ropes and chains tester , perimeter of ropes and chains tester , part 1 rattle test template stand , digital torque tester , digital cap torque tester , sound level calibrator , push-pull scale force gauge , drop tester , pacifier tester , part 1 12mm feeler gap gauge

CTN :39915822 Due date: 24 Apr, 202524 Apr, 2025 NA
Tender For supply of test bench for smgr,gr/cgr angle measurement unit [comprising of three units: smgr tes t bench, gr, cgr angle measurement test set and nr test set ]
 Loading, Please wait...

Connect us via What's Up